Wuxi Lonheo International Trade Co., Ltd. >> Low Voltage-Aluminium Conductor XLPE Insulated PVC Sheathed Power Cable

Low Voltage-Aluminium Conductor XLPE Insulated PVC Sheathed Power Cable

Low Voltage-Aluminium Conductor XLPE Insulated PVC Sheathed Power Cable
Price: US $ 20-50/Meter
Trade Terms: FOB,CFR,CIF
Min Order: 100/Meter
Pay Type: L/C,T/T,D/P,Paypal,Money Gram

1,APPLICATION
YJLV-Aluminium Conductor XLPE Insulated PVC Sheathed Power Cable
This product is suitable for using in power distribution networks or fixed installations for industrial equipments with rated voltage up to and including 0.6/1KV
 
2,BASIC INFORMATION
Code Name 
YJLV
Rated Voltage (Uo/U)
0.6/1KV
Cable Structure
Aluminium Conductor/XLPE Insulation/PVC Sheath
 
 
3,CONSTRUCTION
Conductor
Number of conductors:1,2,3,4,5,3+1,4+1
The conductors shall comply with the requirement given in IEC
Insulation
XLPE(Cross-linked Polyethylene) according to IEC
Sheath
PVC(Polyaluminium Chloride) according to IEC
 

 
4,CABLE  STANDARDS
GB/T12706-2008,IEC,BS,ASTM and etc. upon request.
The electrical and dimensional properties of this product are measured by the Technical and Quality Assurance department at the JiangNan Cables laboratory. Cable performance in respect of conductor resistance, construction quality (workmanship), dimensional consistency, and other parameters are verified to published standards and approved product drawings. Conformance to RoHS (Restriction of the use of Hazardous Substances) is determined and confirmed.
 
 
5,CHARACTERISTICS
Conductor temperature
Maximum conductor temperature in normal use: 90ºC
Max.short-circuit temperature
Maximum shall not exceed 250ºC(5s Max,Duration)
Installation temperature
Ambient temperature under installation shall not be below 0ºC
Minimum bending radius
The bending radius of cable: (D-Diameter of cable) 
-------------------------------------≥15D
 

6,Voltage designation
The rated voltage of the cable for a given application shall be suitable for the operating conditions in the system in which the cable is used,and is expressed in the form of Uo/ U(Um)kV.
Where:
Uo-The rated power-frequency voltage between conductor and screen or   metallic-sheath,for which the cable designed;
U-The rated power-frequency voltage between conductors, for which the cable designed:
Urn-The maximum value of the "hight system voltage " for which the equipment may he operated.
 
7,Rated voltaged of cable applied in three phrase system are given in table
UUmUo
First classSecond class
11.20.60.6
33.61.83.6
67.23.66
101268.7
1517.58.712
20241218
35422126
Note:The first class cable suitable for one single-phrase earth-fault time does not exceed 1 min each time and Max. time not exceed 8 hours.and not exceed 125 hours in all in one year.
The second class cable suitable fir more earth-fault time and more better insulation performance.
 
8,Production Range of cable
TypeNo. of coresNominal Cross sectional area m2
Aluminium conductor
 
YJLV
 
1*1.5-800
21.5-400
31.5-630
41.5-500
3+11.5-630
51.5-500
4+11.5-500
3+21.5-500
*The armoured single-core cables are used for D.C system only. As for A.C system non-magnetic armoured material should be used. Or magnetic isolation measures should be applied.



9,DIMENSIONS-YJLV-Table01
Nominal cross sectional area of conductor(mm²)Nominal insulation thickness(mm)0.6/1KV YJLV
Approx overall diameter(mm)Cable weight max(kg/km)
1x2.50.76.050
1×40.76.458
1×60.77.069
1×100.78.394
1×160.79.3121
1×250.911.2175
1×350.912.4215
1×50*1.014.1278
1×70*1.116.1362
1×95*1.118.2468
1×120*1.218.7539
1×150*1.420.7658
1×185*1.622.6763
1×240*1.725.1952
1×300*1.827.51172
1×400*2.030.91478
1×500*2.234.51861
1×630*2.438.52299
1×800*2.846.02937
*Compacted conductor

DIMENSIONS-YJLV -Table 02
Nominal cross sectional area of conductor(mm²)Nominal insulation thickness(mm)0.6/1KV YJLV
Approx overall diameter(mm)Cable weight max(kg/km)
CircularSector
2x2.50.710.5-95
2×40.711.5-115
2×60.712.5-139
2×100.714.8-195
2×160.716.8-257
2×250.920.4-369
2×350.922.6-460
2×50*1.024.622.4478
2×70*1.128.625.0646
2×95*1.132.229.8849
2×120*1.235.631.41042
2×150*1.439.435.61520
2×185*1.643.838.81800
2×240*1.749.6-2329
2×300*1.854.8-3076
* Compacted conductor

DIMENSIONS-YJLV -Table 03
Nominal cross sectional area of conductor(mm²)Nominal insulation thickness(mm)0.6/1KV YJLV
Approx overall diameter(mm)Cable weight max(kg/km)
CircularSector
3x2.50.711.0-111
3×40.712.0-135
3×60.713.1-167
3×100.715.6-238
3×160.717.8-318
3×250.921.7-463
3×350.924.1-584
3×50*1.026.228.6677
3×70*1.130.832.8929
3×95*1.135.037.01212
3×120*1.238.740.61593
3×150*1.443.045.12010
3×185*1.647.749.62384
3×240*1.753.354.23045
3×300*1.859.159.23810
3×400*2.066.466.04885
*Compacted conductor

DIMENSIONS-YJLV -Table 04
Nominal cross sectional area of conductor(mm²)Nominal insulation thickness(mm)0.6/1KV YJLV
Approx overall diameter(mm)Cable weight max(kg/km)
CircularSector
4x2.50.711.8-131
4×40.713.0-162
4×60.714.2-201
4×100.712.0-290
4×160.719.4-392
4×250.923.8-577
4×350.926.5-731
4×50*1.029.128.0884
4×70*1.134.132.01236
4×95*1.138.837.51595
4×120*1.243.140.22064
4×150*1.447.644.02579
4×185*1.653.150.83085
4×240*1.759.356.83939
4×300*1.865.862.04929
4×400*2.073.969.76351
*Compacted conductor

DIMENSIONS-YJLV -Table 05
Nominal cross sectional area of conductor(mm²)Nominal insulation thickness(mm)0.6/1KV YJLV
Approx overall diameter(mm)Cable weight max(kg/km)
CircularTile Shape
5x2.50.712.7-152
5×40.714.0-190
5×60.715.4-237
5×100.718.5-346
5×160.721.2-470
5×250.926.1-697
5×350.929.0-887
5×50*1.032.7-1132
5×70*1.138.335.81536
5×95*1.143.140.62053
5×120*1.247.644.02541
5×150*1.452.849.03201
5×185*1.658.954.23692
5×240*1.765.861.94882
5×300*1.872.967.26108
5×400*2.082.12-7899
*Compacted conductor
 
DIMENSIONS-YJLV -Table 06
Nominal cross sectional area of conductor(mm²)No.of coresNominal insulation thickness(mm)0.6/1KV YJLV
Approx overall diameter(mm)Cable weight max(kg/km)
CircularSector
3x4+1x2.530.712.7-154
10.7
3x6+1x430.713.9-191
10.7
3x10+1x630.716.3-267
10.7
3x16+1x1030.718.8-365
10.7
3x25+1x1630.922.7-528
10.7
3x35+1x1630.924.7-642
10.7
3x50+1x253*1.027.628.8805
10.9
3x70+1x353*1.132.132.81121
10.9
*Compacted conductor

DIMENSIONS-YJLV -Table 06
Nominal cross sectional area of conductor(mm²)No.of coresNominal insulation thickness(mm)0.6/1KV YJLV
Approx overall diameter(mm)Cable weight max(kg/km)
CircularSector
3x95+1x503*1.136.638.51461
11.0
3x120+1x703*1.240.941.01845
11.1
3x150+1x703*1.444.344.82226
11.1
3x185+1x953*1.649.651.62705
11.1
3x240+1x1203*1.755.357.72441
11.2
3x300+1x1503*1.861.362.84313
11.4
3x400+1x1853*2.068.670.35476
11.6
*Compacted conductor
 
DIMENSIONS-YJLV -Table 07-A
Nominal cross sectional area of conductor(mm²)No.of coresNominal insulation thickness(mm)0.6/1KV YJLV
Approx overall diameter(mm)Cable weight max(kg/km)
CircularTile Shape
4x4+1x2.540.713.7-182
10.7
4x6+1x440.715.1-228
10.7
4x10+1x640.717.9-323
10.7
4x16+1x1040.720.7-445
10.7
4x25+1x1640.925.1-650
10.7
4x35+1x1640.927.5-800
10.7
4x50+1x254*1.031.4-1039
10.9
4x70+1x354*1.136.734.01403
10.9
4x95+1x504*1.140.838.81857
11.0
4x120+1x704*1.245.942.62346
11.1
*Compacted conductor

DIMENSIONS-YJLV-Table 07-B
Nominal cross sectional area of conductor(mm²)No.of coresNominal insulation thickness(mm)0.6/1KV YJLV
Approx overall diameter(mm)Cable weight max(kg/km)
CircularTile Shape
4x150+1x704*1.450.046.62852
11.1
4x185+1x954*1.655.751.83451
11.1
4x240+1x1204*1.762.157.84392
11.2
4x300+1x1504*1.869.863.85501
11.4
4x400+1x1854*2.077.4-7032
11.6
*Compacted conductor
 
 
DIMENSIONS-YJLV -Table 08
Nominal cross sectional area of conductor(mm²)No.of coresNominal insulation thickness(mm)0.6/1KV YJLV
Approx overall diameter(mm)Cable weight max(kg/km)
CircularTile Shape
3x4+2x2.530.713.5-175
20.7
3x6+2x430.714.9-218
20.7
3x10+2x630.717.3-301
20.7
3x16+2x1030.720.1-419
20.7
3x25+2x1630.924.1-604
20.7
3x35+2x1630.925.9-715
20.7
3x50+2x253*1.030.3-935
20.9
3x70+2x353*1.134.933.81258
20.9
3x95+2x503*1.139.038.81631
21.0
3x120+2x703*1.243.942.42134
21.1
3x150+2x703*1.447.046.42511
21.1
3x185+2x953*1.652.651.63084
21.1
*Compacted conductor

DIMENSIONS-YJLV -Table 08
Nominal cross sectional area of conductor(mm²)No.of coresNominal insulation thickness(mm)0.6/1KV YJLV
Approx overall diameter(mm)Cable weight max(kg/km)
CircularTile Shape
3x240+2x1203*1.758.557.63912
21.2
3x300+2x1503*1.864.963.64906
21.4
3x4006+2x1853*2.072.7-6186
21.6
 
10,Product Data Of Cable
Nominal cross-sectional area of conductor(mm²)Max.D.C resistance of conductor at 20ºC(Ω/km)
Aluminium
2.512.1
47.41
64.61
103.08
161.91
251.20
350.868
500.641
700.443
950.320
1200.253
1500.206
1850.164
2400.125
3000.100
4000.0778
5000.0605
6300.0469
8000.0367
Power frequency A.C. Voltage testTest voltage 3.5kV/5 min
 
 

11,Current carrying capacity of cable
l In the air
Aluminium ConductorNominal Cross sectional area of conductor mm2Unarmored cable
Single CoreTwo CoreThree cores
&
Five cores

 

2.524322522
432423429
642564539
1055725850
1671937565
259412010087
35115150120105
50140180150130
70180230190165
95220285235205
120260330275240
150300380315270
185350445365315
240414530415375
300485615480435
400570720560510
500670850650-
6307901000--
8009201180--
 
12Current carrying capacity of cable
l In the ground
Aluminium ConductorNominal Cross sectional area of conductor mm2Unarmored cable
Single CoreTwo CoreThree cores
&
Five cores

 

2.533363631
443474740
656606152
1071757856
16919710085
25115125130110
35140150155130
50165175185160
70205215225195
95245260275235
120280295315265
150315335350300
185360380395340
240420445-395
300475505-445
400545575-510
500620665--
630705760--
800800875--



13,Installation and Operation Condition of Cable
l In the air
1.The distance between two adjacent cable' axle centers of  single-core cables laid in parallel cross-section area of conductor≤185mm²;2 times of the cable diameter cross-sectional area of conductor≥240mm²;90mm
2.Ambient air temperature:30ºC.
3.Max.continous operating temperature of conductor: 90ºC.
l Current carrying rating factors for different ambient air temperature
Ambient air temperature20ºC25ºC30ºC35ºC40ºC45ºC
Correction factor1.091.041.000.950.900.84
 
l Directly in the ground
1.The single-core cables are installed separately.The distance between the cable
center is 2 times of the cable Diameter.
2.Soil temperature: 25ºC.
3.Max.continous operating temperature of
conductor: 90ºC.
4.Thermal resistivity of soil : 1.0 ºC. m/W
5.Depth of Direct-Buried:0.7m.
l Current carrying rating factors for different soil temperature
Soil temperature20ºC25ºC30ºC35ºC40ºC
Correction factor1.041.00.960.920.87
 
Prod Model: Aluminium Conductor/XLPE Insulation/PVC Sheath
Markets: North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe
Rated Voltage: 0.6/1kv
Size: 1.5-800mm2
Application: Power Station
Current: DC & AC
Insulation Material: XLPE
Certification: CCC
Voltage: Low Voltage
Wire Core Material: Aluminum Conductor
Model: Aluminum Conductor XLPE Insulation PVC Sheathe
Brand: Lonheo
Established in 2014 and bringing together the factory more than 30 years of experience in cable, Lonheo is backed by the excellent reputation of our cooperated factory, All what we do is to make them as leading cable contractors in the world.

Lonheo is able to strive in today's competitive business environment by creating synergy and consolidating the resources of all partners. This ensures that Lonheo remains operationally and financially strong.

With this strategic partnership in place, Lonheo is able to help our customers achieve their goals and provide greater value-added services to them.

Our company are focus on cable & wire supplyment and waste water treatment chemicals.

Our Features Product:

===Power Cables===

Ultra High Voltage, Power Cable, High Voltage Power Cable, Medium Voltage Power Cable, Low Voltage Power Cable, LSZH (low smoke zero halogen) Cable, XLPE Cable, AAAC (Aluminium Alloy Conductor) Power Cable, Armoured Cable, SWA (Steel Wire Armoured) Cable.

Power cables are mainly used for power transmission and distribution systems in the power industry and general industries.

===Wires and cables for electrical equipment===

Rubber Insulated Cable, Mining, Drilling & Tunnelling Cable, Ship Cable, Nylon Sheathed Wire, Plastic Insulated Control Cable.

Electrical Equipment Cables are mainly used to supply and distribute electricity.

===Aerial Cable===

Aerial Bundled Cable, Copper Stranded Wire, Aluminium Conductor Steel Reinforced (ACSR) Wires, Aluminium Alloy Conductors (AAAC), Aluminium Stranded Conductor (AAC).

These cables are mainly used as overhead power lines for power transmission and power distribution.

===Special Cables and Wires===

Fire Resistant Cable, High Temperature Resistant Cable, Rodent Resistant Cable / Termite Resistant Cable, Waterproof Cable, Eco-friendly Direct Current cable, Medium Voltage Power Cable for Subway and Light-weight, Wind Energy Cable, 1E Class Nuclear Cable, Energy Efficient ACSR, UHV Supporting and Expanding Overhead Wires, Flexible Fire-proof Cable for 0.6/1KV.

Send your message to this manufacturer

  • Wuxi Lonheo International Trade Co., Ltd.

More >

Other Products From This Manufacturer