I. Main technical parameters
(1) Measurement scope: 2kg/h~500t/h
(2) Accuracy: ± 0.2%~± 0.15%
(3) Work pressure: (0~32) MPa (in case of other high pressure, it must be of special order)
(4) Medium temperature: -50º C~ +350º C,
Measurement accuracy: ± 1º C
(5) Environment temperature: -20º C ~ +70º C
(6) Measurement medium: Liquid, gas, solid, or two phases and three phases mixed fluid
(7) Output signal:
4-20mA current signal of flow, with load resistance ≤ 500Ω
0-10kHz frequency signal of flow.
RS485 Communication protocol
Hart protocol
(8) Power supply voltage: 24VDC
(9) Measurement of measuring pipe: 316L stainless steel
(10) Response time: 0.1s~5s, adjustable
(11) Explosion-proof grade: Ex(ib)II BT2-T5

           Mass flow sensor



Composite type mass flowmeter- all - in- one type


Structure:
 Every meter consists of two parts: the sensor (primary meter) and the transmitter (secondary meter).
The sensor (primary meter) is machinery part of mass flow meter. There are a vibrator, two displacement sensors and a temperature sensor in it.
 
The transmitter (secondary meter) is display part of the meter, also is electrical part. There are power supply, analog circuits, digital circuits, displayer, and output circuits and so on in it. Its foundational functions are receiving and regulating the electrical signal from sensors, directly getting mass flow, temperature and density after regulating, and calculating volume flow and other need parameters from known parameters. It can display, output, store and long distance transmit, and you can modify the parameters of flow meter. There is a diode safety barrier in transmitters; the function of the diode safety barrier is safeguard to isolating explosion.
 
As the composite explosion-proof flow meter, the sensor (primary meter) is essential safety; the transmitter (secondary meter) is explosion isolated. The sensor and the transmitter may all operate under hazardous area. 
 
As the essential safety flow meter, the sensor (primary meter) can operate under hazardous area, the transmitter (secondary meter) must only operate under prescriptive safety area (see section 3.2), forbidden to operate under hazardous area. 
 

The sensor can be installed vertically or horizontally.


1.     Introduction of Coriolis flow meter
 
The Coriolis force mass flowmeter can measure the mass flow rate directly, and won't be affected by the measured medium temperature, pressure, density, viscosity. 

 
High precision of CMF series of Coriolis force mass flowmeter is mainly used to measure the instantaneous mass flow rate and cumulative mass flow, instantaneous volume flow and cumulative volume flow, at the same time also can display the medium temperature, medium density or concentration. It is mainly suitable for the following industries:
(1) he Toil industry, such as diesel, gasoline, heavy oil fuel metering; Crude oil output measurement, moisture content, the single well production; Crude oil loading and unloading metering, etc.;
(2) The chemical industry, such as toluene, xylene, butanone, cyclohexanone, n-butyl alcohol, isobutyl alcohol, methylene chloride, chloroform, liquid sulfur, lactam etc;
(3) The power industry, such as heavy oil, diesel fuel oil metering, slurry density meter limestone-gypsum wet desulphurization;
(4) The food, pharmaceutical industries, such as chocolate syrup, milk, fruit juice, pharmaceuticals, BPC (bulk pharmaceutical chemicals) measurement (clamp type healthy connection type);
(5) The energy industry, such as liquefied petroleum gas, natural gas, high pressure gas metering;

   Introduction
Coriolis Mass Flow Meters patented and developed by our company are the leading meters for precision flow measurement. And with good reason, the meters offer the most accurate measurement available for virtually any process fluid, while exhibiting exceptionally low pressure drop. The meters offer direct mass flow, volume flow, density, and temperature measurement of liquids and slurries - without the need for additional equipment, manual calculations, or estimations.
The meters are designed for unsurpassed performance in even the harshest operating environments. They have no moving parts, and any special mounting or flow conditioning requirements. Every meter is available with stainless steel wetted parts and a wide variety of process connections to meet your every need.
The meters carry hazardous area approval for P. R. China.
1.     Principles of Measurement
The structure of Coriolis Mass Flow Meters was consisted of a pair of bended tubes. The principle is to detect Coriolis force forced a pair of tubes from inner mass flow by fluid.
A new force-Coriolis force would be appear while two conditions met: (1) vibrating with normal frequency in a pair of bended tubes, (2) fluid flowing in tubes. This force was produced upon synthesis from vibrating force and flowing force by fluid in tubes. And tubes would be wresting symmetric the center line because the force forced. Two displacement sensors on sides of tubes detect the force and output electric signals. The signals regulated, mass flow directly produced.
 
2.     Technical Specifications of Products
3.1 Technical Specifications
Table of Technical Specifications (Table 1)
TitlesTechnical Specifications
Mass flow accuracy±[0.2% +(zero stability /flow rate×100%)]
Mass flow repeatability±(1/2) ×[0.2% +(zero stability /flow rate×100%)]
Density range0.2 g/cm3~3.5g/cm3
Density accuracy±0.002g/cm3
Temperature range-60º C~+200º C
Temperature accuracy±1º C
Output of current loop4mA~20mA
Output of frequency/pulse0Hz~10kHz
Contactor capacity of a Batch Control relay24V/0.1A
Contactor formnormal open
 
 
3.2 Other Specifications             Environmental Specifications (Table 2)
TitlesSpecifications
Temperature range of fluid-40º C~+200º C
Environmental temperature range0º C~+40º C
Environmental humidity≤90% RH, non condensation
Atmospheric pressure range86kPa~106kPa
Power supply of transmittersDC (24±10%) V
Power consumed<15W
 
Specifications (Table 3)
SpecsLine Sizes (mm)Flow Range (t/h)Calibration Range (t/h)Max. Tube Pressure (MPa)Zero Stability (t/hr)Velocity  Parameter
(h m/t s)
DN110~0.040.004~0.0430.00.000008353.7
DN330~0.350.035~0.3530.00.00006739.3
DN660~0.70.07~0.730.00.0001619.65
DN10100~1.20.12~1.230.00.00024.912
DN15150~6.40.64~6.44.00.00112.183
DN25250~161.6~164.00.0020.902
DN40400~404~404.00.0030.334
DN50500~656.5~654.00.0060.197
DN80800~16016~1602.50.010.0873
DN1001000~25025~2502.50.0150.0544
DN1501500~55055~5502.50.030.0239
 

4. Configurations of Products
4.1 Classify of Products
Products specs are divided to eleven based on nominal line sizes: DN1, DN3, DN6, DN10, DN15, DN25, DN40, DN50, DN80, DN100, DN150 (units: mm).
4.2 Configurations
                                      
Figure 2 Essential Safety Transmitter   Figure 3 Composite Transmitter and Sensor
    Every meter consists of two parts: the sensor (primary meter) and the transmitter (secondary meter).
The sensor (primary meter) is machinery part of mass flow meter. There are a vibrator, two displacement sensors and a temperature sensor in it.
The transmitter (secondary meter) is display part of the meter, also is electrical part. There are power supply, analog circuits, digital circuits, displayer, and output circuits and so on in it. Its foundational functions are receiving and regulating the electrical signal from sensors, directly getting mass flow, temperature and density after regulating, and calculating volume flow and other need parameters from known parameters. It can display, output, store and long distance transmit, and you can modify the parameters of flow meter. There is a diode safety barrier in transmitters; the function of the diode safety barrier is safeguard to isolating explosion.
As the composite explosion-proof flow meter, the sensor (primary meter) is essential safety; the transmitter (secondary meter) is explosion isolated. The sensor and the transmitter may all operate under hazardous area.
As the essential safety flow meter, the sensor (primary meter) can operate under hazardous area, the transmitter (secondary meter) must only operate under prescriptive safety area (see section 3.2), forbidden to operate under hazardous area. 
Prod Model: CMF
Markets: North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe
Flow Fluid Measured: Liquid, Air, Solid Flow
Output Signal: 4-20mA, Pulse, RS485, Hart
Indicate: Flow Rate, Total Flow, Density, Temperature
Fluid Types: Two-Phase Flow, Three-Phase Flow
Connection: Tube/Flange, Plug-in, Clamp, Snap
Indicator: Density+Mass/Volume Flow+Viscosity+Pressure+Temp.
Explosion-Proof: Intrinsic Safety, Ex-Proof CT6
Accuracy: ≤±0.1%
Main Application: Corrosive Liquid/Gas
Sensor: Clamp-on/External
Type: Coriolis Mass Flow Meter
Measuring Media: Liquid
Measuring Principle: Thermodynamic
Size: Dn1.5~Dn200
Tianjin U-ideal Instrument Co., Ltd is a professional supplier of level instruments, flow meters, gates valves, pressure control valves, pneumatic and electric control ball valves, check valves, globe valve, pressure reducing and sustaining valve and steam traps and strainers from year 2006, are one of the repute' S manufactures in China, We have been cooperated with many famous companies all over the world, and quantities are satisfy all of our customers. Our products have passed the CE, GS, ISO9001 approvals.

Fluid water level switch(float switch, radar level switch, ultrasonic level switch, vertical level switch, horizontal level switch, flange level switch, thread level switch), tank gauges (Magnetic level gauges, glass tubular level gauges, sight glass level indicator, transparent level meter and reflective level gauge, weld glass water meter, oil level meter, fuel level control and indicator), drop-in type level sensor(cable level sensor, pole level switch, hydrostatic pressure level sensor and level transmitter, capacitive level sensor, ultrasonic level transmitter, non-contact level meter and float level transmitter) tank flange level indicators, radar RF level meter and so on.

Flow meters: Metal rotary flow meters(float flowmeter, rotameter, gas rotameter, bypass rotameter), vortex flow meters (steam vortex flowmeter) flow sensor, flow switches and liquid and gas turbine flow meters, conductive fluid electromagnetic flow meters, PD flow meter such as oval gear wheel flow meters, roots flow meters) precession vortex gas flow meters, flow sensor and other flowmeasurement instruments.

Ultrasonic Level, Ultrasonic Level Measurement, Level Measurement, Level Sensors, Ultrasonic Level Sensors, Ultrasonic Flow Meter, Ultrasonic Level Probe, Ultrasonic Meter, Ultrasonic Distance Meter, Ultrasonic Meters, Ultrasonic Level Detection, Ultrasonic SensÖ R, Ultrasonic Sensors, Ultrasonic Level Sensor, Level Sensor Ultrasonic, Ultrasonic Measuring, Ultrasonic Testing, Sensor Ultrasonic, Ultrasonic Measurement. Water Level Sensor Switch, Water Level Sensor, Water Level Sensor Circuit, Level Sensor Water, Liquid Level Sensor, Magnetic Level Switch, Magnetic Switch, Oil Level Sensor, Magnetic Float Switch, pressure transmitter, differential pressure transmitter.

Safety valve, pressure control valve, safety relief valve, pressure relief valve, pressure transmitters, pressure gauge, temperature gauge

Welcome to contact us, we will reply you in 24hours.

Send your message to this manufacturer

  • Tianjin U-Ideal Instrument Co., Ltd.

More >

Other Products From This Manufacturer