Application:
AR Series Online UPS for Industry are widely used in the fields of Petroleum, chemical, large datacenters, manufacturing industries, power transmission, rail transportation, aviation, centralized control center, offshore drilling platforms, precision medical equipment protection, communications networks and other automated control systems.

Product Description:
AR Series Online UPS for Industry60KVA
Model: AR-IND60KVA 
Type: Online
Input AC Voltage: AC380V/400V/415V/480V, 3P3W or 3P4W
Input DC Voltage: DC348V
Input Frequency: 50Hz/60Hz± 10%
Output AC Voltage: AC380V/400V/415V/480V 3P3W or 3P4W, AC220V/230V/240V/277V 1P2W
Output Frequency: 50Hz/60Hz± 0.1%
Protection: Short Circuit, Lightning, EMC Filter, Galvanic Isolated Transformer
Display: Touch-Sensitive LCD Operating Panel
Interface: Dry contact, RS232, RS485 (MODBUS)
Notes: Other specifications are available upon request


Features & Advantages:
1. Adopting output isolated, on-line double coversion technology and advanced DSP technology. It is a full digital and intelligent new generation UPS
2. IGBT components with PFC function.
The input power factor is more than 0.985. Effectively reduce the input harmonic and reactive power loss, a really energy efficient UPS for industry.
3. Friendly, full intelligent touch type man-machine interface design to use a 7 inch color LCD display.
It is informative and easy to operate. Easy to perform and modify the initial preset of UPS,
It can adapt to the power supply standards of various countries around the world, supports multi language interface conversion.
4. Ultra-strong overload ability and adopting the technology of five-section overload protection. It is suitable for harsh industrial loads and compatible with the hardware and software
5. The efficiency of the machine is more than 94%, therefore reduce the energy consumption.
6. Adopting negative power detection and anti reverse connection technology, IGBT anti common circuit circulation detection and protection technology which greatly improve the reliability of the system.
7. The key PCBs with conformal coating to protect against the moisture, salt mist and mildew, therefore can withstand the harsh environment of high contamination and high pollution.
8. Advanced and Intelligent battery management system
(1). Exclusively adopting the 3iBMSTM battery wisdom third-order management system which can be preset to a regular test of the battery charge and discharge and with temperature compensation function, thus simplify the battery maintenance procedure, extend the battery life and reduce the battery replacement cost.
(2). With the unique function of automaticlly correct the discharge cut-off voltage of the battery low discharging current to avoid the battery deep discharge resulted in a permanent damage to battery
(3). With the Intelligent battery connection detection and battery reverse connection protection. Therefore any connection mistake and power on/off in a wrong order will cause no harm to the battery.
9. Intelligent Fan Rotation Speed Control with the fault diagnosis function and the redundancy design
The fan rotation speed can change automatically according to the load capacity and the actual temperature, thus improve the system reliability and greatly reduce the audible noise.
10. Plug & Play Module Design Plug & Play Module Design to allow for quick maintenance and troubleshotting.
11. Dry Contacts, RS-232/ RS485 (MODBUS) as standard configuration, SNMP card and remote control panel are available for option.
12. History Data Record Ability
The unlimited quantity of the history data can be stored, can be downloaded to U disk. Therefore the user can analyse the operation status of the UPS.
13. Compatibility design, custom-made non-standard UPS, reserved interface for parellet redundancy with multi-units

Technical Specifications:
Capacity (KVA)60
PhaseInput Phase:  3P3W or 3P4W
Output Phase: 1P2W or 3P3W  or 3P4W
Other specifications are available upon request
ModelAR-IND10KVA ~ AR-IND200KVA

RectifierIGBT Rectifier with PFC Power Factor Correction 
InputAC Voltage AC380V/400V/415V/480V, 3P3W or 3P4W
Other specifications are available upon request
AC Voltage Range±30%/-20%
Frequency50Hz/60Hz±10%
Power Factor>0.95

Inverter3-Phase Independent Full-Bridge IGBT Converter
OutputAC Voltage AC380V/400V/415V/480V 3P3W or 3P4W
AC220V/230V/240V/277V  1P2W
Other specifications are available upon request
Voltage Regulation±1%
THDHarmonic Distortion<2% for linear load, Harmonic Distortion<3% for non-linear load
Frequency and Accuracy50Hz/60Hz±0.1%
Phase Shift Under 100% Unbalance Load< 0.5°
Output Power Factor0.8
Overload<110%Continuous
125%10 minutes
150%1 minitue
200%10 seconds
Current Crest Ratio3:1
Efficiency (100% Load)≥94%

BatteryRated Battery VoltageDC348V, other specifications are available upon request
Battery Cold Start with DCYes, UPS can be started without AC source

Physical Width x Depth x Height(mm)550 x 800 x 1800
Net Weight (Kg)650
ColorRAL7035 Anti-ultraviolet light grey
Environment MaximumTemperature                (100% Load)40ºC: Continuous
50ºC: Less than 8 hours
Humidity<90% (Non-Condensing) 
Altitude<2000 M Above Sea Level
Protection Levels for Cabinet IP42
Audible Noise< 60 dBA (At 1 M)
Regulation & StandardsSafe Standard (CE Standard)EN50091-1
EMC Standrad (CE Standard)EN50091-2
Radiation and SafeStandardFCC, CLASS A, CE
EMC/EMITransmission EN50091-2
Radiation EN50091-2, CLASS A
Harmonic Current IEC1000-3-4
Anti - InterferenceEN61000-4-2.3.4.6.8.9.11 Level III, EN61000-4-5 Level IV
PretectionShort Circuit, Lightning, EMC Filter, Galvanic Isolated Transformer
Communication InterfaceDry contact, RS232, RS485 (MODBUS)
Notes: 1. Different specifications required are available.
2. All the specifications mentioned above are subject to change without prior notice.
3. The appearance and color are for referrence only, the object as the standard.

Standard Configuration:
1. Output Isolated Low Frequency Transformer
2. IGBT Rectifier Module with PFC Power Factor Correction
3. Full-bridge IGBT Inverter Module
4. Static Bypass Components
5. Manual Maintenance Bypass Switch
6. Dual Independent Operation Large-scale DSP Control Components
7. Software and Hardware Redundancy Backup Control Components 
8. Heavy Load Type Steel Structure Based on Industrial Environment Design 
9. Touch-Sensitive LCD Operating Panel
10. Expandable Parallet-Redundant Components
11. 3iBMS TM Intelligent Battery Management System 
12. Intelligent Fan Speed Control Redundant Components
13. Dry Contacts, RS-232/ RS485 (MODBUS) Communication Port

Options:
1. Iutput Isolated Low Frequency Transformer
2. Bypass Isolated Low Frequency Transformer 
3. Industrial-grade Bypass Isolated Voltage Stablizer Cabinet
4. Industrial-grade Input/Output Feeder Cabinet
5. ATS (Automatic Transfer System)
6. STS (Static Transfer Switch)
7. Touch-Sensitive and Color LCD Operating Panel for Remote Monitoring
8. E.P.O (Emergency Power Off)
9. Top Cable Entry and Top Cable Exit Connection Components
10.SNMP Communication Card for Network Monitoring 
11. Customized High Current Charging Module 
12.Nickel-Chromium Battery Chraging Module

Prod Model: AHR-60K-3
Markets: North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe
W X D X H (Mm): 550 X 800 X 1800
N.W.(Kg): 650
Color: Ral7035 Anti-Ultraviolet Light Grey
Input AC Voltage: AC380V/400V/415V/480V, 3p3w or 3p4w
Input DC Voltage: DC348V
Xiamen Orientronic Co., Ltd. is a professional and dependable OEM/ODM manufacturer and exporter of high-end UPS for industry and electricity. Our company consists of a head quarter and three factories each specializes in OEM/ODM industrial UPS, SMT PCB assembly services and mold & molding fabrications.

Our OEM/ODM UPS can be classified into five grades: Nuclear grade, electricity grade, maritime grade, industrial grade and general grade. Beside the reliable UPS equipment, we also provide our customers with comprehensive power system solutions to ensure continuous power for rugged industrial infrastructure applications, including oil and gas, transportation, power generation, power transmission and distribution, and process manufacturing.

We dedicate nearly 10% of our turnover to R&D. As a result we are always being one technological step ahead. With a group of innovated, creative and motivated engineers who have more than 20 years experience in the research and development of uninterruptible power supply (UPS) systems, with a skilled dedicated workforce and with the valuable experiences of cooperation with many famous power supply companies in the world, we are honored by our customers as the most powerful and reliable partner for the OEM/ODM industrial UPS. We have the abilities to deliver the best power solutions and quality custom-made industrial UPS products to meet your specific power demands and guarantee to deliver exactly what you need.

We focus on the field of OEM/ODM high-end UPS for industry and electricity. Just because of the focus, we are so professional. We sincerely hope to cooperate with clients from all over the world.