Hangzhou Huier Cable Co., Ltd. >> 12 Core 12ta Stranded Tc PVC Insulated Alarm Cables and Wires

12 Core 12ta Stranded Tc PVC Insulated Alarm Cables and Wires

12 Core 12ta Stranded Tc PVC Insulated Alarm Cables and Wires
Price: US $ 0.15-0.2/Meter
Trade Terms: FOB,CIF,EXW
Min Order: 300/Roll
Pay Type: L/C,T/T
Description: 22 AWG 4/C SOL FPL-CL2
Compliance: UL Standards 13 & 1424; NEC Articles 725 & 760
Construction:
Conductor: 22 AWG Solid Bare Copper
No. of Conductors :4 
                             Insulation 
Type :                Polypropylene
Color               Blk, Red,Ylw,Grn
Thickness          0.006" nom.
Diameter             0.036" nom.
Lay Length              N/A
                                Jacket
Type                         PVC
Color                        Red
Thickness           0.015" nom.
Diameter              0.122" nom.
Properties:
Temperature Rating        -20 to 75 oC
Operating Voltage           300 Volts max.
Capacitance                       15 pf/ft nom.
Impedance                       100 Ohms nom.
DC Resistance             17.0 Ohms/M' at 20oC
Flame Rating                  UL 1685 Vertical Tray


Our product range:
1.Coaxial cable, indoor optical cable
2.Network cables: Cat3, Cat5 UTP, Cat5 FTP, Cat5e UTP, Cat5e FTP, Cat5e SFTP, Cat6 UTP, Cat6 FTP, Cat6 SFTP, Figure 8 cables with messenger
3.Local communication cables: telephone cables, indoor telephone cables, speaker wire, CCTV wire
Fire Alarm Cable Information

Fire Alarm Wire and Cable is somtimes abbreviated to FPLR and FPLP that stands for riser and plenum. Fire alarm cable is used for many sound and security systems including audio, PA and intercom systems. It comes in awg sizes 22 through 18 in as many conductors as 12 in riser and plenum wires.

The riser fire alarm cable comes in s shielded and unshielded version which may be needed depending on the application. The plenum fire alarm cable also comes in the shielded and unshielded version because both could possibly be needed in certain situations.

We also stock the contractor grade fire alarm cables in shielded, unshielded, riser and plenum which only comes in a red jacket with solid copper conductors. Please call for pricing on the contrator grade material.

Power-Limited Fire Alarm System Cables
Three types of power-limited fire alarm cables are currently in use. These are: FPL, FPLR and FPLP.
Type FPL power-limited fire alarm cable is listed by the NEC as being suitable for general purpose fire alarm use. This listing excludes installation in risers, ducts, plenums and other space used for environmental air unless the cable is installed in conduit. All FPL cables are listed as being resistant to the spread of fire and must pass both UL test 1424 and vertical flame test UL 1581.
 
Type FPLR power-limited fire alarm riser cable is listed as being suitable for use in a vertical run in a shaft or from floor to floor. All FPLR cables are listed as having fire-resistant characteristics capable of preventing fire from traveling floor to floor. Riser cables must pass both UL test 1424 and the vertical riser flame test UL 1666.
  
Type FPLP power-limited fire alarm plenum cable is listed by the NEC as being suitable for use in ducts, plenums and other space used for environmental air. All FPLP cables are listed as having adequate fire-resistant and low smoke-producing characteristics and must pass both UL test 1424 and UL tunnel test 910.
Power-Limited Wiring Methods and Materials
Power-limited circuit conductors and cables described in section 760-71 of the NEC must be installed in the following ways:
Installed in raceways or exposed surfaces.
 
Protected against physical damage.
  
In metal raceways or rigid nonmetallic conduit where passing through a floor or wall to a height of 7 feet above the floor, unless adequate protection can be afforded by the building construction.
 
In rigid metal conduit, rigid nonmetallic conduit, intermediate metal conduit or electrical metallic tubing where installed in hoistways.
 
 
 
Listing Requirements
Conductor and cables for power-limited fire alarm circuits shall be listed for the purpose and meet the following requirements:
Conductors are solid or stranded copper. 
 
Conductors in a multiconductor cable shall not be smaller than 26 AWG. Single conductors shall not be smaller than 18 AWG.
The voltage rating shall not be marked on the cable. Voltage ratings marked on the cables may be misinterpreted to suggest that they can be used for Class 1, electric light and power applications. There are exceptions for cables with multiple listings or in cable substitutions.


Cable Substitutions

Cable Type
Cable Substitutions
FPLPCMP
FPLRCMP, FPLP, CMR
FPLCMP, FPLP, CMR, FPLR, CMG, CM

 
 
Conductors of Different PLFA Circuits
Cable and conductors of two or more PLFA circuits, communications circuits or Class 3 circuits are permitted in the same cable, enclosure or raceway.
 
Conductors of one or more Class 2 circuits are permitted with conductors of PLFA circuits, provided that the insulation of the Class 2 circuit conductors is at least that required by PLFA circuits.
 
Special Cable Constructions
The increased demand for addressable fire alarm systems and the need to conform to the Americans with Disabilities Act (ADA), have created many changes in fire cable constructions. In response to this new demand, Signal Cable Company now supplies a wide variety of low and mid-capacitance cables.
 
Low and Mid-Capacitance Cables
Capacitance refers to a cable's unique ability to store an electric charge and to resist sudden changes in the magnitude of that charge (voltage). It is found not only between the two wires of a twisted pair, but also between adjacent conductors in the same cable. The capacitance between two adjacent conductors is called the mutual capacitance and is expressed in picofarads per foot (pf/ft). In high frequency digital transmissions, mutual capacitance distorts the square wave shape of the signal, causing errors in data transmission. The larger the capacitance, the higher the distortion and error rate.
 
Addressable fire alarm systems using advanced electronics allow the fire alarm panel to communicate with each base individually using a sophisticated polling process. In some instances, more than 100 devices can be located on a single pair of wires. Due to this need for faster and clearer signal transfer, the capacitance of the cable has become a concern.
 
New Changes in 2008 NEC Code Article 760
Added the requirements for fire alarm system conductors to comply with 300.8 [see NC 760.24]
 
Added cable ties as a means of support [see NEC 760.24]
 
Relocated equipment on removing accessible portions of abandoned cables and added requirements on the durability of tags used to identify cable(s) intended for future use [see NEC 760.25]
 
Revision to specify the intended objective of identifying fire alarm circuits at terminal and junction locations [see NEC 760.30]
 
Added requirements for NPLFA and PLFA power sources to be supplied by an individual branch circuit [see NEC 760.41, 760.121]
 
Added 300.7 to compliance requirements for installation for PFLA cables and conductors [see NEC 760.130(B)]
 
Revised to include mixed circuit classes in a cable tray [see NEC 760.139]
 
Added requirements that NPLFA cables used in wet locations must be listed for use in wet locations or have a moisture-impervious metal sheath [see NEC 760.176]
 
Added requirements for PLFA cables used in wet locations must be listed for use in wet locations or have a moisture-impervious metal sheath [see NEC 760.179]
 
Review of Cable Requirements
All installations must follow guidelines established by the National Electric Code. Below are some basic practices to remember when installing power-limited fire alarm systems. For a more in-depth review of requirements and installation guidelines, refer to the NEC.
All cables must be UL listed. Check all cables for the proper markings.  Refer to NEC Article 760.
 
Comply with local wiring requirements.
 
Only use conductors made of copper.
  
Test wiring for grounds, short circuits and open faults before the system is placed in operation.
  
Always use the proper gauge of wire to avoid line loss.
 
Avoid interference when routing wiring.
 
Installation shall be made to prevent the spread of fire from floor to floor.
 
A minimum of 6 inches of free conductor is required in each electrical box to facilitate termination.
 
All wiring must be terminated with UL listed devices.
 
Local Codes
Most states and cities adopt the NEC. A few states and cities amend the NEC recommendations regarding cable requirements. Any variances in code are easy to obtain through local officials. Check the local codes to determine if the NEC has been adopted in your area.
 
 


Established in 2004, Hangzhou Huier Cable Co., Ltd is a Sino-Foreign Joint Venture. It is located in a strong economic province-Hangzhou, Zhejiang, which is 200 kilometers from Shanghai and Ningbo sea port. The traffic is very convenient. It's only two hours' drive to Shanghai Pudong Airport, one hour to Hangzhou Xiaoshan International Airport and two hours to the world-famous Mount Huang.
 
We have standard workshops of 25000 square meters with advanced inspection & production equipments. At present, our annual production is 150000 kilometers of all environmental series of 75ohm & 50 ohm coaxial cable, video-monitoring cable, cable & optical cable specially used for railways and ships and 100000 standardizing boxes of various shielded network data cables.
 
We always follow ISO9000 quality system & ISO14001 environment management system strictly. Through UL and ETL, all products have certifications of RoHS test and CE authentication. We own about one hundred patents, and register brands in Russia, the Philippines, USA and Madrid. We have excellent cable engineers and designers who can provide services like intelligent building settlement and technical support for our customers. Though in emergency, please trust the reputation of Huier on the ability of production, storage & transportation and on-time delivery. We will send the whole inspected cables to you as soon as possible. At present, Our Huier products are exported to North America, South America, Europe, Southeast Asia, Australia etc.
 
Prod Model: Fire Alarm Cable
Markets: North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe
Type: Bare
Conductor Type: Stranded
Application: Underground
Conductor Material: Copper
Insulation Material: PVC
Certification: RoHS
Brand: Customer Made
Established in 2004, Hangzhou Huier Cable Co., Ltd is a Sino-Foreign Joint Venture. It is located in a strong economic province-Hangzhou, Zhejiang, which is 200 kilometers from Shanghai and Ningbo sea port. The traffic is very convenient. It' S only two hours' Drive to Shanghai Pudong Airport, one hour to Hangzhou Xiaoshan International Airport and two hours to the world-famous Mount Huang.

We have standard workshops of 25000 square meters with advanced inspection & production equipments. At present, our annual production is 150000 kilometers of all environmental series of 75ohm & 50 ohm coaxial cable, video-monitoring cable, cable & optical cable specially used for railways and ships and 100000 standardizing boxes of various shielded network data cables.

We always follow ISO9000 quality system & ISO14001 environment management system strictly. Through UL and ETL, all products have certifications of RoHS test and CE authentication. We own about one hundred patents, and register brands in Russia, the Philippines, USA and Madrid. We have excellent cable engineers and designers who can provide services like intelligent building settlement and technical support for our customers. Though in emergency, please trust the reputation of Huier on the ability of production, storage & transportation and on-time delivery. We will send the whole inspected cables to you as soon as possible. At present, Our Huier products are exported to North America, South America, Europe, Southeast Asia, Australia etc.

Established in 2013, Hangzhou Belief Import&Export Co., Ltd is an import and export company covering the industry of cable, lighting, metal, chemical, equipment, garment etc. With the advantage of location, we' Re building a good platform for our customers to purchase more and better products in Greater China.

Send your message to this manufacturer

  • Hangzhou Huier Cable Co., Ltd.

More >

Other Products From This Manufacturer