Categories
Price: | US $ 18.8/Piece |
---|---|
Trade Terms: | FOB,CFR,CPT |
Min Order: | 200/Piece |
Pay Type: | L/C,T/T,Paypal,Money Gram,Western Union |
Prod Model: | s-400 |
---|---|
Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
Protection Function1: | Overload Protection Overheat Protection Input Over |
Output Type: | Single |
Output Power: | 301 - 400W |
Input Voltage: | Full Range |
Voltage Regulating Mode: | Frequency Modulation Type |
Connection Mode: | Series Switching Power Supply |
Starting Mode: | Self-excited Switching Power Supply |
Warranty: | 2 Years |
Power Supplying System: | Level 1 Power Distribution Equipment |
Certification: | CSA |
Model | S-400-5 | S-400-12 | S-400-15 | S-400-24 | S-400-36 | S-400-48 | |
output | DC voltage | 5V | 12V | 15V | 24V | 36V | 48V |
Voltage tolerance | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | |
Rated current | 60A | 33A | 27A | 16.5A | 11A | 8.3A | |
Current range | 0~60A | 0~33A | 0~27A | 0~16.5A | 0~11A | 0~8.3A | |
Rated power | 300W | 396W | 405W | 396W | 396W | 398.4W | |
Ripple&noise | 100mvp-p | 150mvp-p | 150mvp-p | 150mvp-p | 180mvp-p | 200mvp-p | |
DCvoltage ADJ.range | -9%~+10% | ±10% | ±10% | ±10% | ±10% | ±10% | |
input | Voltage range | 90~132VAC/180~264VAC(selected by switch),255~373VDC | |||||
frequency | 47~63HZ | ||||||
AC current | 7.5A/115VAC,4.5A/230VAC | ||||||
efficiency | 78% | 80% | 80% | 82% | 82% | 83% | |
Inrush current | Cold start current30A/115VAC,60A/230VAC | ||||||
Leakage current | < 3.5mA/240VAC | ||||||
protection | overload | Rated output power105%~135% start over load protection | |||||
protection type :rated current limit ,auto-recovery after fault condition is removed | |||||||
Over voltage | 6.8~8.2V | 15.6~17.8V | 18.6~20.8V | 30.6~33.2V | 42.6~44.2V | 54.8~56.6V | |
Protection type:hiccup mode,auto-recovery after fault condition is removed | |||||||
Over temperature | ≥55°Cfan on,≤50°Cfan off,≥85°C start over temperature protection | ||||||
Protection mode:cutoff output,auto-recovery after temperature become normal | |||||||
environment | Working temp,humidity | -10°C~+60°C,20%~90%RH | |||||
Storagetemp,humidity | -20°C~+85°C,10%~95%RH non-condensing | ||||||
Withstand vibration | 10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes | ||||||
safety | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
Isolation resistance | I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC | ||||||
Fitstandard | Safety standard | Compliance to UL1012 | |||||
EMC standard | Compliance to EN55022,CLASSA | ||||||
others | Dimension | 215*115*50mm(L*W*H) | |||||
Weight/packing | 1.0kg/24pcs/25kg/0.049 m³/1.72CUFT | ||||||
note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25°Cof ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |
Model | S-400-5 | S-400-12 | S-400-15 | S-400-24 | S-400-36 | S-400-48 | |
output | DC voltage | 5V | 12V | 15V | 24V | 36V | 48V |
Voltage tolerance | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | |
Rated current | 60A | 33A | 27A | 16.5A | 11A | 8.3A | |
Current range | 0~60A | 0~33A | 0~27A | 0~16.5A | 0~11A | 0~8.3A | |
Rated power | 300W | 396W | 405W | 396W | 396W | 398.4W | |
Ripple&noise | 100mvp-p | 150mvp-p | 150mvp-p | 150mvp-p | 180mvp-p | 200mvp-p | |
DCvoltage ADJ.range | -9%~+10% | ±10% | ±10% | ±10% | ±10% | ±10% | |
input | Voltage range | 90~132VAC/180~264VAC(selected by switch),255~373VDC | |||||
frequency | 47~63HZ | ||||||
AC current | 7.5A/115VAC,4.5A/230VAC | ||||||
efficiency | 78% | 80% | 80% | 82% | 82% | 83% | |
Inrush current | Cold start current30A/115VAC,60A/230VAC | ||||||
Leakage current | < 3.5mA/240VAC | ||||||
protection | overload | Rated output power105%~135% start over load protection | |||||
protection type :rated current limit ,auto-recovery after fault condition is removed | |||||||
Over voltage | 6.8~8.2V | 15.6~17.8V | 18.6~20.8V | 30.6~33.2V | 42.6~44.2V | 54.8~56.6V | |
Protection type:hiccup mode,auto-recovery after fault condition is removed | |||||||
Over temperature | ≥55°Cfan on,≤50°Cfan off,≥85°C start over temperature protection | ||||||
Protection mode:cutoff output,auto-recovery after temperature become normal | |||||||
environment | Working temp,humidity | -10°C~+60°C,20%~90%RH | |||||
Storagetemp,humidity | -20°C~+85°C,10%~95%RH non-condensing | ||||||
Withstand vibration | 10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes | ||||||
safety | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
Isolation resistance | I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC | ||||||
Fitstandard | Safety standard | Compliance to UL1012 | |||||
EMC standard | Compliance to EN55022,CLASSA | ||||||
others | Dimension | 215*115*50mm(L*W*H) | |||||
Weight/packing | 1.0kg/24pcs/25kg/0.049 m³/1.72CUFT | ||||||
note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25°Cof ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |