Technical  Features
 Four new comprehensive upgrades----Faster more accurate more convenient
1. Inside heating
    No pre-heating step outside,operate easily.
2. Durable pump tubing
    Maintenance free micro pump,accurate sample volum,accurate results,imported high performance pump tubing,using life is for 1000 tests.Reduce replacement frequency,easier operation.
3. Filter for avoiding blockage
    With filter device for sample,avoid blockage,reduce failure rate greatly.
4. Pressure monitor
    With pressure testing device,monitor pressure at all times,results are more credible.
 
6 Items of Test Technology Ensuring Accurate Results
 
(1)Accurate Principle of Methodology 
    Adopts classical and accurate principle of methodology - Ion exchange liquid chromatography, It is the gold standard of HbA1C analysis, and it is the only analysis method to really separate HbA1C   directly by measuring the piecemeal absorbance through continuous test on line,? and obtain the correct area percentage with integration. 
 
(2) Accurate separation 4-gradient elution 
  The novel 4-gradient elution for HbA1C can separate accurately glycated hemoglobin with 4-gradient elution of corresponding concentration reagent aiming at HbA1C instead of routine ?elution   process produced by high and low concentration mixture. 
 
(3)High Separation Liquid Chromatographic Column 
  High separation liquid chromatographic column made of imported resin with volume of Φ 9mm x 45mm and weight of 2.5g which is 15-20 times greater than general micro chromatographic column.   High efficiency chromatographic column for 300 tests ensure the accuracy of test results. 
 
(4) High Sensitivity 415nm LED Integral Photometer
High sensitivity 415nm LED integral photometer has the characteristics of correct wavelength, stable light source, full aluminum alloy structure, high anti-interference performance, multi-lens focusing, micro cuvettes and high sensitivity. It can record accurately analysis curve. 
 
(5)Supply with Original Calibrator 
The international standard value tracing is adopted. The authoritative reference material for quality control is used to transfer the numeric value. Each set of reagent is supplied with two sets of calibrator for proper calibration so as to ensure that the test results are correct and reliable and thoroughly to avoid individual error caused by factor calibration.
 
(6) Precision Chromatographic Column and Thermostatic Apparatus
Precision chromatographic column and reagent thermostatic control apparatus ensure that Chromatographic column and reagent are not affected by environment temperature and effectively guarantees the repeatability and correctness of the test results.
 
 6 Items of Human Oriented Design, Convenience, Speed and Reliability
 
(1)Real-time summarized chromatogram, Intelligence process detection 
The advanced embedded micro processing system + intelligence control software can  really display testing curve and the real redisplay of testing process and can monitor and alarm for test results, absorbency, signal potential, peak time and reagent consumption. It can be operated with high proficiency.
 
(2) Full-auto 25-position Sample Turntable, Optional Selection of Batch Test or    Emergency Test 
With full-auto 25-position sample turntable, it is unnecessary to use complicated rank sampling device and built-in hemolysis device. Batch test can be automatically carried out. Emergency test can be carried out at any time. 
 
(3)Full-open Structure, perfect flow path, low failure and easy maintenance
  Full-open structure, Perfect solenoid valve flow path, it is unnecessary to use complicated sample mechanical 6-way and rotating distribution control valve. It is reliable for use and easy for maintenance. 
 
(4)5μl whole blood, three-step test, for both labs and clinics 
  5μl whole blood, simple pretreatment, the whole blood sample can be tested on instrument after whole blood sample is added with hemolytic agent through three-step simple operation. Both venous blood and peripheral finger blood can be tested. 
 
(5)With gas solution and bubble-removal technology, the error can be eliminated overall. 
  Since the instrument is equipped with reagent solvability gas eliminating device and applies the cuvette bubble auto detection eliminating technology, the air bubbles which affect the test results can be eliminated overall without the complicated degassing device. 
 
(6)Saccharification concentration, area percentage and average glucose can be synchronously reported. 
  The instrument can output the data including IFCC concentration value, NGSP area percentage and ADAG average glucose on the test report synchronously to meet the requirement of world standardization. It may memorize 1000 test curve reports and is equipped with RS232 communication interface and can connect directly to HIS/LIS system.

Model Full-auto glycated hemoglobin HbA1c Analyzer

Basic Parameters
Testing Method   Low pressure ion exchange liquid chromatography
Testing Item   glycated hemoglobin HbA1c
Testing Scope   3% ~ 18%
Testing Parameters   Precision (CV) ≤3%, Accuracy (V) ≤1.50%
Testing Time   4 minutes (including reporting)
Sample type   venous blood (EDTA anticoagulation),Peripheral finger blood
Sample volume5μl whole blood for each sample

Functional Parameters
Photometer  415nm LED Integral flow colorimeter
Sampling mode Full-auto 25-position sample turntable (20 sample positions, 2 quality control positions, 1 emergency position, 1 cleaning position, 1 zero position)
Testing mode     auto test for batch, single test for emergency
Calibration    Optional selection of 2 points or 4 points calibration, optional selection of manual or automation, Equipped with 2 groups of high and low level calibrators
Thermostatic control   Column and reagent thermostatic control: 25 ± 0.5ºC
Reagent matching one piece of column and reagent consumable/300 pieces of testing samples
Reagent allocation  Each standard package includes A, B, C, D eluent, calibrator, hemolytic agent, pump tubing

Output Parameters
Display     320x240 LCD Graphic Display, displaying real-time testing curve
Printer58mm Thermal printer, printing testing curve and report
Report Output    IFCC concentration value, NGSP area percentage, ADAG average glucose
Data storage   1000 test report (including testing curve)
Communication interface  RS232 communication interface, connecting to HIS/LIS system

Working Parameters
Power Supply     AC220V±22V 50Hz 215VA
size     408mm×390mm×230mm
Weight     9kg
Working Environment    Temperature 12ºC-30ºC,Relative humidity ≤85%

 
 
Prod Model: DB-GHA6601
Markets: North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe
Testing Scope: 3% ~ 18%
Testing Parameters: Precision (CV) ≤3%, Accuracy (V) ≤1.50%
Photometer: 415nm LED Integral Flow Colorimeter
Power Supply: AC220V±22V 50Hz 65va
Size: 408mm×390mm×230mm
Weight: 8kg
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Glycated Hemoglobin Hba1c Analyzer
Debonnie Medical Equipment Co., Ltd provides professional export service for Medical Instruments and Equipments.

We cooperate with the most professional manufacture (with ISO/CE/FDA certificates) and technical teams, providing customized services to meet all kinds requirements for medical equipments and services.

Debonnie----Owns one stop service platform which is Professional, High-efficient, Flexible, convenient, as well as superior quality product, complete service and the most competitive prices, will be your most thoughtful and reliable cooperation partners in China.

Send your message to this manufacturer

  • Debonnie Medical Equipment Co., Ltd.

More >

Other Products From This Manufacturer