Xinchi Electric Co., Ltd. >> Electric Contactors LC1-D Type

Electric Contactors LC1-D Type

Electric Contactors LC1-D Type
Price: Negotiable/Piece
Trade Terms: FOB
Min Order: 10/Piece
Pay Type: L/C,T/T,Western Union,Paypal

Product Specifications

Prod Model: LC1-D
Markets: North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe
Professional Manufacture: 10 Years
Quality Guarantees: 2 Years
Model No: LC1-D LC1-Dn or Other
Certification: CE CCC
Hz: 50/60Hz
Number Of The Contacts: 3p+No 3p+Nc
Operation: Manual Type
Circumstance Temperature: -5°c~40°c
Brand: Suntree/OEM
Theory: Voltage Relay
Size: Miniature
Usage: Start&Control AC Motor

Product Description

Electric Contactors LC1-D type

MC contactor

MC magnetic ac contactor  is suitable for using in the circuits up to the rated voltage 660VAC 50Hz or 60Hz, rated current 9A to 85A, making and breaking and frequent starting, controls the AC motor. Combined with the auxiliary contact group, air delayer, machine interlocking device etc, it is combined into the delay contactor, mechanical interlocking contactor, drat-delta starter, with the thermal relay, it is combined into the electro magnetic starter. This product conforms to the requirement of IEC 60947 4 -1 & GB14048.4 standards

Features                                                                                                                            

  5 Frame Sizes
  1/2HP up to 75HP 480V AC
  Screw Terminals (Lug Terminals Available)
  Direct Mounting Overload Relays
  Optional accessories
  Additional Auxiliary contacts
  Replacement Coils
  Reversing Wiring Sets and Interlocks
  Coil surge Suppressors

General Specifications                                                                                                                                  
Maximum Voltage 600V AC
Rated Frequency 50/60Hz
Operating Temperature -5°C (23°F) to +50°C (104°F)
Degree of protection IP20
Resistance to Vibration (5-300Hz) > 15g

Technical Data

Type

MC
-9

MC
-12

MC
-18

MC
-22

MC
-32

MC
-40

MC
-50

MC
-65

MC
-75

MC
-85

AC3 duty

9A

12A

18A

22A

32A

40A

50A

65A

75A

85A

AC1 duty

20A

20A

25A

32A

50A

60A

80A

100A

110A

135A

AC3 duty

200~
240V

2.5kW
11A

3.5kW
13A

4.5kW
18A

5.5kW
22A

7.5kW
32A

11kW
40A

15kW
55A

18.5kW
65A

22kW
75A

25kW
85A

380~
440V

4kW
9A

5.5kW
12A

7.5kW
18A

11kW
22A

15kW
32A

18.5kW
40A

22kW
50A

30kW
65A

37kW
75A

45kW
85A

500~
550V

4kW
7A

7.5kW
12A

7.5kW
13A

15kW
22A

18.5kW
28A

22kW
32A

30kW
43A

37kW
60A

45kW
64A

45kW
75A

690V

4kW
5A

7.5kW
9A

7.5kW
9A

15kW
18A

18.5kW
21A

22kW
25A

30kW
33A

37kW
47A

45kW
47A

45kW
52A

thermal  current(Ith)

20A

25A

30A

32A

45A

50A

70A

80A

90A

100A

AC
motor

Single
phase

115V

0.5HP

0.5HP

1HP

2HP

2HP

3HP

3HP

5HP

5HP

7.5HP

230V

1HP

2HP

3HP

3HP

5HP

5HP

7.5HP

10HP

15HP

15HP

Three
phase

200V

2HP

3HP

5HP

7HP

7.5HP

10HP

10HP

15HP

20HP

25HP

230V

3HP

3HP

5HP

7.5HP

10HP

10HP

15HP

20HP

25HP

30HP

460V

2HP

7.5HP

10HP

10HP

20HP

25HP

30HP

40HP

50HP

50HP

575V

5HP

10HP

15HP

15HP

20HP

25HP

30HP

40HP

50HP

50HP



LC1-D AC contactor
Application
1)LC1-D series AC Contactor
is suitable for using in the circuits up to the rated voltage 660V AC50Hz or 60Hz,
rated current up to 95A, for making, breaking, frequently starting & controllingthe AC motor.
2)Combined with the auxiliary contact block, timer delay & machine-interlockingdevice etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter.With the thermal relay, it is combined into the electromagnetic starter.
3)The product conforms to IEC60947-4-1 CE stardand.
Standard Control Circuit Voltage
Volts244248110220230240380400415440500600
50HzB5D5E5F5M5P5U5Q5V5N5R5S5Y5
60HzB6D6E6F6M6-U6Q6--R6--
50/60HzB7D7E7F7M7P7U7Q7V7N7R7--

LC1-D AC contactor Technical Data

Type
LC1-D09LC1-D12LC1-D18LC1-D25LC1-D32LC1-D40LC1-D50LC1-D65LC1-D80LC1-D95
Rated working current (A)AC39121825324050658095
AC43.557.78.51218.524283744
Standard power ratingsof 3-phase motors 50/60Hz in category AC-3220/230V2.2345.57.5111518.52225
380/400V45.57.5111518.522303745
415V45.5911152225374545
500V5.57.5101518.52230375555
660/690V5.57.5101518.53033374555
Rated heat current (A)2020324050608080125125
Electrical lifeAC3 (x104)100100100100808060606060
AC4 (x104)20202020201515151010
Mechanical life (x104)1000100010001000800800800800600600
Number of the contacts3P+NO3P+NC+NO
3P+NC

LC1-D AC contactor Dimensioned


TypeABCDEab
LC1-D09~1247768211313334/3550/604.5
LC1-D1847768711813834/3550/604.5
LC1-D2557869512614640484.5
LC1-D32578610013115140484.5
LC1-D40~657712911614516540100/1106.5
LC1-D80~958712912717519540100/1106.5


LC1-D AC contactor
Application
1)LC1-DN series AC contactor is suitable for frequency 50/60Hz, rated insulation voltage up to1000V,
rated operation current 9~150A under AC-3 duty. It is mainly used for making/breaking electric circuits at a long distance & for frequent
starting/stopping & controlling AC Motors.
2)It isused in combination with thermal relay to compose a magnetic motor starter.
3)The products com-ply with IEC60947-4-1 standard.
Standard Control Circuit Voltage
Volts244248110220230240380400415440500600
50HzB5D5E5F5M5P5U5Q5V5N5R5S5Y5
60HzB6D6E6F6M6-U6Q6--R6--
50/60HzB7D7E7F7M7P7U7Q7V7N7R7--


LC1-DN AC contactor Technical Data

Type
LC1-DN09LC1-DN12LC1-DN18LC1-DN25LC1-DN32LC1-DN38LC1-DN40
Rated working current Ie (A)
AC-3 Ue≤440V
9121825323840
Rated hear current Ith (A)25253240505060
Rated insulation voltage Ui (V)6906906906906906901000
Rated operating voltage Ue (V) Max6906906906906906901000
Rated operational power in AC-3 Pe (KW)220/230V2.2345.57.5911
380/400V45.57.5111518.518.5
415/440V45.59111518.522
500V5.57.5101518.518.522
660/690V5.57.5101518.518.530
Rated operational power in AC-4 Pe (KW)220/230V1.51.52.23444
380/400V2.23.745.57.57.59
415/440V2.233.75.57.57.59/11
500V345.57.59911
660/690V45.57.510111115
Frequency of operation (I/h)
1200120012001200100010001000
Electrical endurance (x104)AC-3100100100100808080
AC-420202020202015
Mechanical endurance (x106)
1515151515156
Operating voltage range of coilClose voltage:(0.85~1.1)Us Open voltage:(20%~75%)Us
Power consumption of coil (VA)Atracting77777720
Starting707070707070200
Rated insulation voltage of auxitiary contacts (V)690690690690690690690690
Conventional thermal current of auxitiary contacts (A)1010101010101010
Auxitiary contacts speecificationAC-15:360VA DC-13:33W

TypeLC1-DN50LC1-DN65LC1-DN80LC1-DN95LC1-DN115LC1-DN150
Rated working current Ie (A)
AC-3 Ue≤440V
50658095115150
Rated hear current Ith (A)8080125125200200
Rated insulation voltage Ui (V)100010001000100010001000
Rated operating voltage Ue (V) Max100010001000100010001000
Rated operational power in AC-3 Pe (KW)220/230V1518.522253040
380/400V223037455575
415/440V25/303745455980
500V303755557590
660/690V3337454580100
Rated operational power in AC-4 Pe (KW)220/230V5.57.57.59911
380/400V1111151518.522
415/440V1111/15151518.522
500V1518.522223037
660/690V18.52225253045
Frequency of operation (I/h)
10001000750750750750
Electrical endurance (x104)AC-3606060606060
AC-4151515151515
Mechanical endurance (x106)
664444
Operating voltage range of coilClose voltage:(0.85~1.1)Us Open voltage:(20%~75%)Us
Power consumption of coil (VA)Atracting202020202222
Starting200200200200300300
Rated insulation voltage of auxitiary contacts (V)690690690690690690690
Conventional thermal current of auxitiary contacts (A)10101010101010
Auxitiary contacts speecificationAC-15:360VA DC-13:33W
LC1-DN AC contactor Dimensioned


Type0912182532384050658095115150
b76.676.676.676.676.676.6127127127127127158158
c878787949494116116116123.8123.8132132


LC1-F AC contactor
Application
LC1-F series
AC contactor is applicable in the circuits up to the rated voltage 1000V AC 50Hz or 60Hz,rated
curent 780A, for long distance breaking circuit and frequently starting or control the motor.
It also can be used for the control of distribution circuits of rated current from 200A TO 1600A.

LC1-F AC contactor Technical Data

Type
LC1-F115LC1-F150LC1-F185LC1-F225LC1-F265LC1-F330LC1-F400LC1-F500LC1-F630
Rated operation current (A)AC-3115150185225265330400500630
Standard power ratings of 3-phase motors AC-3(KW)220V3040556375100110147200
380V557590110132160200250335
415V5980100110140180200280375
440V5980100110140200250295400
500V7590110129160200257335400
660V80100110129160200280335450
1000V6565100100147160185335450


3TB AC contactor
Application
The contactor is suitable for using in the circuit up to the rated voltage 660V AC 50Hz or 60Hz,
rated current 630A, for making and breaking, and for frequent starting and controlling the motor.
After combined with the mechanical interlocking device, it becomes 3TD Series convertible contactor
for Controlling, starting, breaking and Reversing of the motor.
The products comply with IEC947 & VDE0660.

3TB AC contactor Technical Data

Type
3TB-403TB-413TB-423TB-433TB-44
Rated insulation voltage660660660660660
Rated operational current(380V)AC-3912162232
AC-43.34.37.78.515.6
Rated outputs of three-phase
motors at 50Hz
AC-3230/220V2.43.346.18.5
400/380V45. 57.51115
500V5.57 .5101121
690/660V5.57.5111123
1000V-----
AC-4400/380V1.41.93.547.5
690/660V2.43.366.613
(×106)Mechanical endurance1010101010
Switchina frequencyAC-31.01.01.01.01.0
AC-40.20.20.20.20.2
(×106)Mechanical enduranceAC-310001000750750750
AC-4250250250250250
Coil voltage lolerance(0.8~1.1)Us
Power consumption of coil
(50Hz)
Closed1010101010
Cos0.290.290.290.290.29
Closing6868686868
Cos0.820.820.820.820.82
Convention althermal current2020303045
Conventional thermal current
of auxiliary contacts
1010101010
Rated operational current
of auxiliary contacts
AC-15
380/220V
6/106/106/106/104/6
Weight0.430.430.490.490.7
The number of AC coil voltageCoil for 50Hz ACCoil for 50Hz/60Hz AC
24BO24C1
42DO42D1
110FO110G1
220MO220P1
240UO240R1
380QO--


3TH AC contactor
The auxiliary contactors is the auxiliary suited by controlled circuit with voltage is AC 50/60Hz,660V
and DC 660V.They control all kinds of magnetic coil and amplify or transfer signal to relative
controlled element simultaneously. They are characterized by high performance & long service life.

3TH AC contactor Technical Data

Rated Voltage
Rated operational current(A)Controllable motor power AC3(KW)
le=AC11, AC14DC11
110V-0.9-
220V100.452.2
380V6-4
440V-0.254
660V2-4
m
TypeType of contact
NONC
3TH3041
31-OA32
22-OA23
13-OA14
04-OA--
3TH40/3TH80 40-OA41
31-OA32
22-OA23
13-OA14
04-OA--
3TH42/3TH82 80-OA8-
71-OA71
62-OA52
53-OA54
44-OA4-


3TF AC contactor
1)3TF Series AC Contactors are latest products in 1990's.The series products are suitable for
frequency of 50/60Hz,rated insulation voltage up to 690-1000V,rated opreational current up to 9A-400Aat raetd operational voltage up to 380V under the utilization category AC-3.
2)3TF Sersies AC Contactors are mainly used for making breaking electric circuits at a ling distance
and for frequent starting stopping and reversing control of AC motors
3)They comply with IEC947,VDE0660, MGB14048.

3TF AC contactor Technical Data

Type
Rated thermal
current(A)
Rated operation current(A)Controllable power of motor(KW)Type of auxliliary
contact
AC-3AC-4
380V660V380V660V380V660V
3TF30209745.51.42.4NO
NC
1NO+1NC
2NO+2NC
3TF3120127.55.57.51.93.3
3TF32301612.57.5113.56
3TF33302216.5101546.6
3TF3455322415227.513
3TF3555382418.522915.5
3TF40209745.51.42.4
3TF4120127.55.57.51.93.3
3TF42301612.57.5113.56
3TF43302216.5101546.6
3TF4455322415227.513
3TF4555382418.522915.5
3TF4680454022371220.82NC+2NO
4NC+4NO
3TF4780636030551424.3
3TF48100756037551729.5
3TF49100858045752136
3TF501601109555902746.9
3TF51160140120751103560
3TF52200170160901503866
3TF532102051651101605086
3TF5430025023013222058100
3TF5530030026016025066114
3TF5640040038020035581140
3TF68630630600335560160278


Household AC Contactor
Application
1)The product is mainly applicable to a power system of AC 50Hz (or 60Hz), rated working voltage up
to 230V, and in a line of application class AC-7a with rated working voltage up to 230V and rated working current up to 20A.
It is used to remotely close or/and switch off the line.
The product is widely used in dwelling houses, hotels and so on.
2)The product is in conformity with the standards: GB 17885 IEC 1095.
Normal operation and mounting requirement
1)Circumstance temperature -5°C ~ +40°C, average temperature within 24h not exceeding +35°C.
2)Altitude above sea level less than 2000 m.
3)Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
4)Installation class II
5)Pollution class 2.
6)Installation method DIN Rail mounting type.
7)Product shall be vertically mounted onto standard Din rail 35mm.


Household AC Contactor Technical Data
Ratings
Utilization
category
Ui (V)Ui (V~)Conventional
heating current (A)
Ie (A)Controlled
power (kW)
AC-1, AC-7a AC-7b5002306363/2513/3.8
AC-1, AC-7a AC-7b5002304040/158.4/2.4
AC-1, AC-7a AC-7b5002303232/126.5/1.9
AC-1, AC-7a AC-7b5002302525/8.55.4/1.9
AC-1, AC-7a AC-7b5002302020/74/1.2
Making and breaking capacity
Utilization
category
Making and breaking conditionsElectrification
time (s)
Interval
time (s)
Operating
cycle times
Ic/IeUr/UeCOS
AC-1, AC-7a1.51.050.80.051050
AC-7b81.050.450.051050
Conventional operating performances
Utilization
category
Making conditionsBreaking conditionsElectrification
time (s)
Interval
time (s)
Operating
frequency
Ic/IeUr/UeCOSIc/IeUr/UeCOS
AC-11.01.050.81.01.050.80.05106000
AC-7a1.01.050.81.01.050.80.051030000
AC-7b6.01.00.451.00.170.450.051030000
(16A~25A) 1P, 2P Household AC Contactor Dimensioned

Xinchi Electric Co., Ltd. is the best one, which stands out above the rest in China intelligent low voltage electrical field, meanwhile it is a grouping company in the "city of electrical".There are four branch companies subordinate to it:Yueqing Xinchi Electric Sci-Tech Co., Ltd, Yueqing Imp&Exp Co., Ltd, HK Yangming Electrical Technology Co., Ltd and Wenzhou Litto smart Co., Ltd.Moreover.There are 320 workers, the annual output value breakthrough one hundred million, and the export value arrive at ten million.
We always pay attention to manufacture and sell automatic industrial and control system, modular intelligent electrical equipments, such as circuit breakers, residual circuit breakers, contactors, isolators, solid state relay, control and protect switch, automatic transfer switch, electrical fire detecting system, surger protect device, multifunctional meter and new energy system fittings etc.
Especially DC circuit breaker, DC isolating switch, DC fuse, busbar chamber, waterproof switch and other products with leading technical level in this field...We are the first domestic company with CE, CB, IEC, Nemko, SAA, TUV, ISI and CCC certification.Our products are widely used by domestic famous enterprises, and it has become a OEM partner of many international famous brands.

We have fully implement the IS09001:2008 quality management system.It adopts advanced production equipment and precision detecting equipment, introduces high-tech process and high technology talents to provides powerful guarantee for product development, quality upgrading and management innovation of the company.
In order to seek after the excellence, Xinchi will continue to carry on the spirit of "practice, honesty, innovation, active", insist on the policy of " technology promotes industry, Brand promotes industrial", and we believe in "Technology innovation, famous in the world", working hard to let"XINCHI electric brand"walk towards to the world.

Send your message to this supplier

  • Xinchi Electric Co., Ltd.