Key Specification
WM series low voltage withdrawable electric cabinet is suitable for power generation and supply systems with power levels of 3-phase AC 50Hz, rated working vlotage 400V(690V) andrated current up to 4000A, satisfying power distribution, motor centralized control and apacitance compensation.
The cabinet has its function unit adopted with modular design, enabling flexible and convenient unit combination, which can achieve and replace all proposals and functions owned by modified MNS, standard GCS, modified GCS as well as GCK available in the market.
Dimension of Cabinet
Height * Width * Depth
2200mm 600mm 800/1000mm
800mm 800/1000mm
1000mm 800/1000mm
Main Characteristics
1. Main circuit plug: It is of stainless material, with stable and reliable performance, the waffled plug with four copper sheets as a gang, each has a separate contact spring fixation structure with strong withstand overload current capability.
2. Sencond conncetor: more convenient and more attracive.
3. Hinge: Used at drawer doors and fixed doors, installation of embedded type(without welding studs), all with high-precision allumen hinges, can improve the overall outlock of the cabinet, to ensure consistency of protection degree.
Applicable Standards:
GB3906-97 "AC metal closed switchgear 3-35kV"
GB/T11022 "Technical Requirements on High Voltage Switch Device & Control Device Standards"
IEC60298 "AC Metal Enclosed Switch and Control Device above 1kV, below 50kV"
DL404-97 "ordering technical qualification of in-door AC high-voltage switch cabinet"
Working Conditions of Cabinet
Environment temperature:-10°C--40°C
Environment humidity: the daily average value should be no greater than 95%, the monthly average value should be no greater than 90%
Altitude: lower than 1000m
Earthquake proof degree: earthquake intensity no more than 8 degrees
The around atmosphere should not contain distinct pollutions such as corrosive or flammable gas or steam
No severe contamination or frequency severe vibration, and the design of rigid grade under condition should meet the requirements of grade 1
If the working conditions can not meet the environmental requirements of GB3906,please negotiate with the manufacturer
Notes: 1. Electric heater should put in operation when relative humidity exceeds 70%
2. When working site is beyond the altitude of 1000m,it should conform to JB/Z101-71
Technical parameter
items | Unit | parameter |
Rate voltage | kV | 12 |
Rate frequency | Hz | 50 |
Rated main bus bar current | A | 630 ,1250,1600,2000,2500 ,3150 |
Rated branching bus bar current | A | 630 ,1250,1600,2000,2500 ,3150 |
Short-time withstand current(4S) | kV | 20,25,31.5,40 |
Peak withstand current(peak.) | kV | 50,63,80,100 |
Rated short drop out current | kV | 20,25,31.5,40 |
Rated short circuit open and cut(Peak) | kV | 50,63,80,100 |
Rated insulation level | 1min power frequency withstand voltage | ph-ph,ph-ground | kV | 25,30,42 |
breaker gap | kV | 27,34,48 |
Rated lighting impulse withstand voltage(Peak) | ph-ph,ph-ground | kV | 40,60,75 |
breaker gap | kV | 46,70,85 |
Suzhou Silverstone Electric Specialises in Power Transmission, Distribution, Electrical Automation Solutions, Power Quality Solutions, Hydro Power, Solar Power, Power Generation and Substation EPC Consultant.
We manufactures and trades
Power Transformer
--Dry type Transformer (up to 35kV)
--Oil Immersed Transformer (up to 230kV)
GIS (Gas Isolated Switchgear)
--Up to 145kV Compact Gas Insulated Switchgear (GIS)
--Up to 230kV Gas Insulated Switchgear (GIS)
MV Switchgear
--Metal clad AC Enclosed Switchgear
--Packaged Type AC Metal Enclosed Switchgear
--Gas Insulated Switchgear
LV Switchgear
--LV Withdrawable Switchgear
--LV Fixed Switchgear
MV Circuit Breaker
--Vacuum Circuit Breaker
--SF6 Circuit Breaker
--MV Earthing Switch
--Load Break Switch
Reactor
--Dry-type Air Core Reactor Series
--Dry-type Core Series Shunt Reactor
--HV Oil-immersed Shunt Reactor
HV&LV Busbar Trunking System
--Busbar Trunking System (Busway)
--Common Enclosure Busbar
HV Circuit Breaker & Disconnector
--HV Circuit Breaker
--SF6 Circuit Breaker
--HV Disconnector
--Outdoor AC discontector
--HV Earthing Switch
--Outdoor AC Earthing Switch
Capacitor
--All film high voltage shunt capacitor
--High-voltage shunt capacitor banks
--Atlernating filter capacitor complete equipments
Power Protection & Automation
Reactive Compensation
High Voltage Frequency Reactor
Medium voltage variable frequency drives
Medium voltage soft starter
STATCOM (Static synchronous compensator)
Static var compensator with Magnetically controlled reactor
TSC (Thyristor switched capacitor banks)
Active power filter