Raylabel Instrument Co., Ltd. >> Gas-Chromatograph for Analysis Instrument (RAY-GC112A)

Gas-Chromatograph for Analysis Instrument (RAY-GC112A)

Gas-Chromatograph for Analysis Instrument (RAY-GC112A)
Price: US $ 1.00/Piece
Trade Terms: FOB,CIF,EXW
Min Order: 1/Piece
Pay Type: L/C,T/T,Western Union
Specifications
Temperature control
Control range: 7° C - 400° C above room temperature. (increment of 1° C)
Control objects: Column oven, detector, thermal conductive pond and sample injector
Programmed temperature rising: 5 ramps
Rate of programmed temperature rising: 0.1° C -40° C(increment of 0.1° C)
Thermostatic time: 0-655 min(increment of 1 min)

FID
Sensitivity (minimum testability): M£ 5'10-11 g/s (sample: C16)
Optimum testing result: M£ 1'10-11 g/s
Noise: £ 5'10-14 A
Drift: £ 6'10-13 A/h
Linear range: ³ 106

TCD
Sensitivity: ³ 2000mV. Ml/mg
Noise: £ 20mV
Drift: £ 30mV
Linear range: ³ 104

ECD
Temperature range: 350° C Max
Measuring mode: 63Ni
Sensitivity: £ 10-13 g (Benzex)
Linear range: ³ 103

FPD
Sensitivity (minimum testability): £ 2'10-11 g (P)/s (sample P in the parathion methyl)
Optimum testing result: £ 3.8'10-12 g (P)/s.
Sensitivity (minimum testability): £ 1'10-10 g (S)/s (sample: S in the parathion methyl)
Optimum testing result: £ 2.7'10-11 g (S)/s
Linear range: ³ 103 (sample P parathion)
³ 102 (sample S parathion)
Stability: £ 30mV/h
Noise: £ 10mV
Starting time: Not greater than 2 hours

NPD:
Sensitivity (minimum testability): Dt(N)£ 5pg (N)/s (sample: Azobenzene)
Optimum testing result: 0.5ppm
Sensitivity (minimum testability): Dt(P) £ 0.5pg (P)/s (sample: Malethion)
Optimum testing result: 0.2ppm
Drift: £ 810-13 A/h
Noise: £ 510-13 A
Linear range: ³ 103
Max application temperature: 360° C
Characteristics
Brand-new designed microcomputer temperature control system of world advanced control technology. High accuracy of temperature control (optimum: ± 0.05 ), high reliability and anti-interference.
Control and operating parameters (including for detectors) set up by the keyboard. Self-diagnosis system, power-fail protection, file storage and call, limited temperature setting. Accurate display of setting and actual value of temperature control of each path, bridge current of TCD, sensitivity of FID, retention and analysis time.
Four paths of independent control sections: column oven, sample injector, detector and thermal conductive pond.
5-ramp programmed temperature rising control. Auto-drop of temperature of column oven (auto-opening the door behind the oven) to a fast cooling.
Dual FID provided with options of GC 112 A -TCD, GC 112A -ECD, GC 112 A -FPD and GC 112A -NPD, gas sampling valve, transformation oven, absorber and pyrolysis absorber available for selection. Two detectors can be installed at the same time with high sensitivity. Short time to be stabilized and easy to clean and install nozzle.
Packed column and capillary column (0.53 large diameter or small diameter) can be installed easily including a complete set of split sampling connector and tailing connector to be installed free of charge. Optional 0.53mm large diameter capillary direct sampler is available for choice.
Analysis can be conducted in packed or capillary column with multiple sampling methods.
Packed column: on-column sampling, instantaneous vaporized sampling and gas sampling.
Capillary column: split sampling and 0.53mm large diameter capillary direct sampling.? Construction of dual gas path, dual sample injector and dual packed column system can effectively avoid baseline undulation and drift in real time and facilitate programmed temperature rising analysis. Accurate and scaled type gas path control valves will provide a high repeatability and stability.
Advanced functions: auto ON/OFF temperature control system, permanent data storage, file storage and call and over-temperature protection.
Large volume column (300x280x270) can hold capillary column and dual packed column. Built-in heating filament structure is in favor of quartz capillary analysis.
A complete set of accessories including purifier, pressure-reducing valve, gas path tube, wrench and tools, injection needle and connectors of all kinds are provided free of charge and are ready to connect with supply-air system prepared by users.

Prod Model: RAY-GC112A
Markets: North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe
Temperature Control: 7° C - 400° C
Chromatography Type: Gas Chromatography
Ray Type: Gamma Ray Spectrometer
Gaspath System: Three
Spectrometer Detector: SDD
Energy Resolution: ≤7%
Detector: Fid,Tcd,Ecd,Fpd,Npd
Raylabel Ltd., founded in 2005.

We are a professional manufactures laboratory equipments, medical apparatus and school furniture which have a very powerful R&D team and now becoming the professional Lab equipments total solution provider in this field. Our company has obtained ISO9001: 2000 and ISO13485: 2003 certificate of quality management system registration approval. Raylabel products show extremely long life span and stability in the function.

All the sale engineers from Raylabel Ltd., have strong professional experience. Some of them have been more than 15 years. Our company operates its business with the management philosophy of "customer first, service forever". We are proud of the supporting with our perfect quality of products and timely service systems. And we sell our products to all parts of the country and overseas.

Based on the global instrument market awareness and marketing strategies, Raylabel products are increasingly becoming excellent OEM supplier and partner, We will based in China to provide more advanced and high quality products and better service.

Our goal is to be an international lab equipments and school furniture supplier worthy of trust, and we are dedicated to benefiting our customers by minimizing their cost with reasonable prices and maximizing their profits with trouble free products.

Choose "Raylabel", Choose a Most Valuable Business Partner!