Guang Zhou Biao Ji Packing Equipment Co., Ltd. >> GC9800 Gas Chromatography

GC9800 Gas Chromatography

GC9800 Gas Chromatography
Price: Negotiable/Piece
Trade Terms: FOB,CFR,CIF
Min Order: 1/Set
Pay Type: L/C,T/T

Product Specifications

Prod Model: GC9800

Product Description

1. Gc9800 Gas Chromatography Carry out the quantitative analysis and peculiar smell testing for residual solvent on food packaging cases after printing.
2. Test the pureness and quality of organic solvents.

Features
---Economic, practical and with high price-performance ratio.
---The design of the cellular integral structure is convenient for installation.
---It can be connected to the chromatogram data work station so as to greatly improve the working efficiency.
---It has eight-step temperature rise.
---The configuration can be made as per your requirements and five detectors can be chosen and used according to the analytic requirements.
Hydrogen flame ionization detector (FID) for organic compounds analysis with high sensitivity
Thermal conductivity detector (TCD) used to analyze permanent gas, water and low-carbon mix.
Flame photometric detector (NPD) applicable for analysis of pesticide residue, sulphur and phosphorous.
Electron capture detector (ECD) applicable for analysis of pesticides and chlorine solvent.
Nitrogen and phosphorous detector (NPD) applicable for the detection of trace amount of nitrogen and phosphorous
---With the flexible design of the packed column and capillary column injection ports.
Packed column and capillary column sample injectors can be selected as per actual situations.
---Wide column box (300mm× 300mm× 200mm)
In order to meet complicated analytic task, it makes use of various chromatographic columns so as to offer convenience and widen the range of the analytic samples.

The advanced noise suppression system can fully eliminate the fan noise under the chromatogram working state, so as to provide you a comfortable and quiet working environment.
---The sampling device is completely vitrified with two modes of rapid vaporizing and column sample injection.
---Brand-new pressure stabilization and various air circuit system
The air circuit has three different forms: Single, double and triple. It can match six-way valve, blow back, and precut equipment and so on according to the users' demands. It adopts new type pressure regulation system to ensure the re-productivity of equipment.
---Reforming furnace can be equipped to implement microanalysis of CO and CO2.
---Cracking furnace can be equipped to do double eight-step temperature rise with microcomputer control, man-machine conversation and simple application.
---Advanced temperature control system
---Adopt microcomputer control and man-machine conversation to indicate needed temperatures of various temperature column boxes.
---Control scope: (room temperature +10° C) - 400° C, eight-step temperature rise.
---The speed is 0 - 30° C/min (with increase 0.1° C/min), and the temperature control precision is 0.1%.
The control point number is eight points of A type and control scope (room temperature +10° C) is - 400° C.
---Overheat protection function
It can freely set any temperature within 400° C and is provided with double fail-safe design of software program protection and hardwired connection.

Reference of technical specification

Thermal conductivity detector (TCD)
Hydrogen flame ionization detector (FID)
Electron capture detector (ECD)
Flame-photometric detector (FPD)
Nitrogen and phosphorous detector (NPD)

Sensitivity
S≥ 5000mv. Ml/mg (benzene)
M≤ 1× 10-11/sec
M≤ 2× 10-13G/ml (r-666)
Ms≤ 5× 10-11g/sec (thiophene)
MP≤ 1× 10-11g/sec (1605)
Mn: 1× 10-13G/sec
MP: 1× 10-13G/sec

Noise
≤ 0.02mv
≤ 1× 10-14A

≤ 2× 10-12A

Datamation (chromatogram data workstation)
It adopts chromatogram data workstation, can provide multifunctional methods of single, double and quaternary channels and can perform inter-channel processing. In addition, it can save the analytic data and provide special analytic methods.
Cooperation

We are the lab solution provider for the food, pharmaceutical, packaging, printing industries, research institution and college with qualified instruments and service. The machines are running well in over 3000 laboratories to guarantee the highest quality and save cost for customers. We gain increasing good reputation from worldwide customers recent years.

R&D department

With over 1000m2 laboratory and developing center. The experts and technical team come from chemical, electronic, mechanical and software field abroad and domestic. We've been continuously researched and development for new products and the improved current products, and supply with the first technical service for you. It is our honored as the technical innovation enterprise and gain the government support.

Service & Support

24 sales group serve for international and domestic customers. Local agent and office provide instant support. Technical and after-sale service team help you to solve all the problems for easy operation and friendly using. We are thankful for customers' support and staff dedication to continued success.