Categories
Price: | US $ 100/Piece |
---|---|
Trade Terms: | FOB,CFR,CIF |
Min Order: | 1/Piece |
Pay Type: | L/C,T/T |
Basic Technical Data Of BROATEK Desiccant Air Dryer | |
Heatless Desiccant Air Dryer | Heat Purge Desiccant Airy Dryer |
Intake Temperature: 2~45ºC | Intake Temperature: 2~45ºC |
Inlet Oil Content: ≤0.1PPM | Inlet Oil Content: ≤0.1PPM |
Working Pressure: 0.6~0.95MPa | Working Pressure: 0.6~0.95MPa |
Dew Point Pressure: -20~-40ºC | Dew Point Pressure: -20~-40ºC |
Regeneration air capacity: ≤14% | Regeneration air capacity: ≤7% |
Screw Standard: GB/T7306 | Screw Standard: GB/T7306 |
Power Consumption: 100w | Power Consumption: 80% |
Flange standard: HG20592 | Flange standard: HG20592 |
Desiccant: Activated Alumina | Desiccant: Activated Alumina |
Control Method: Micro PC Automatical | Control Method: Micro PC Automatical |
Installation: Indoor Location, anchor bolt installation | Installation: Indoor Location, anchor bolt installation |
Compression Heat Desiccant Air Dryer | Compressed Air Combined Type Desiccators |
Intake Temperature:120~180ºC | Regeneration air capacity : ≤3% |
Inlet Oil Content:≤0.1PPM | Dew Point Pressure: -40~-60ºC |
Working Pressure: 0.6~0.95MPa | Pressure Loss: ≤0.05MPa |
Dew Point Pressure: -12~-60ºC | Standard Cycle Period: 4~8hours |
Working Cycle: 4~8 Hours | Desiccant lifetime: 3~5years |
Power Consumption: 200w | Screw Standard: GB/T7306 |
Flange standard: HG20592 | Flange standard: HG20592 |
Pressure Loss: ≤0.04MPa | Networking Remote Diagnosis |
Regeneration air capacity : ≤1% | Control Method: Micro PC Automatical |
Control Method: Micro PC Automatical | Installation: Indoor Location |
Heatless Desiccant Air Dryer | |||||||
Model | Capacitym3/ min | Dimension mm | Inlet/outlet | Desiccant | Weight | ||
L | W | H | Size | Weight (kg) | (kg) | ||
BDAH-08 | 0.8 | 500 | 480 | 1320 | R1/2 | 16 | 55 |
BDAH-17 | 1.7 | 600 | 540 | 1680 | R3/4 | 34 | 78 |
BDAH-26 | 2.6 | 739 | 700 | 1660 | R1-1/4 | 52 | 150 |
BDAH-38 | 3.8 | 739 | 700 | 1906 | R1-1/4 | 72 | 235 |
BDAH-55 | 5.5 | 900 | 885 | 1880 | R1-1/2 | 104 | 275 |
BDAH-69 | 6.9 | 950 | 925 | 1760 | R1-1/2 | 138 | 336 |
BDAH-80 | 8 | 1024 | 1000 | 1845 | DN50 | 170 | 375 |
BDAH-100 | 10 | 1024 | 1000 | 1995 | DN50 | 200 | 420 |
BDAH-135 | 13.5 | 1024 | 1000 | 2320 | DN50 | 270 | 480 |
BDAH-170 | 17 | 1200 | 1000 | 2180 | DN65 | 300 | 560 |
BDAH-220 | 22 | 1332 | 1200 | 2345 | DN65 | 440 | 740 |
BDAH-270 | 27 | 1382 | 1200 | 2152 | DN80 | 570 | 900 |
BDAH-320 | 32 | 1466 | 1200 | 2150 | DN80 | 640 | 1020 |
BDAH-370 | 37 | 1466 | 1200 | 2370 | DN80 | 700 | 1140 |
BDAH-450 | 45 | 1633 | 1370 | 2464 | DN80 | 870 | 1450 |
BDAH-550 | 55 | 1730 | 1400 | 2684 | DN100 | 1060 | 1800 |
BDAH-650 | 65 | 1936 | 1400 | 2670 | DN125 | 1340 | 2180 |
BDAH-850 | 85 | 2236 | 1650 | 2823 | DN125 | 1600 | 2500 |
BDAH-1100 | 110 | 2280 | 2190 | 3100 | DN150 | 2000 | 3200 |
BDAH-1300 | 130 | 2400 | 2200 | 3200 | DN150 | 2300 | 3500 |
BDAH-1600 | 160 | 2650 | 2400 | 3400 | DN150 | 2900 | 4600 |
BDAH-1900 | 190 | 2738 | 2190 | 3270 | DN200 | 3400 | 5500 |
BDAH-2200 | 220 | 3146 | 2540 | 3490 | DN200 | 4400 | 6900 |
BDAH-2600 | 260 | 3800 | 3000 | 3800 | DN250 | 5200 | 8000 |
BDAH-3000 | 300 | 4000 | 3000 | 3800 | DN250 | 6000 | 8900 |
Inlet Temperature: 2~50ºC Inlet oil content: ≤0.1PPM Working Pressure: 0.6-1.0MPa Pressure Dewpoint: -40~-60ºC Regeneration air capacity: ≤14% Desiccant: Activated Alumina Control Method: Micro Computer-Control Installation Method: Indoor Location, anchor bolt installation. | |||||||
Heat Purge Desiccant Air Dryer | |||||||
Model | Capacitym3/ min | Dimension mm | Electric Heat | Desiccant | Weight | ||
L | W | H | Power(kw) | Weight (kg) | (kg) | ||
BDAP-38 | 3.8 | 739 | 700 | 1906 | 1.8 | 72 | 300 |
BDAP-55 | 5.5 | 885 | 900 | 1880 | 2.6 | 104 | 410 |
BDAP-69 | 6.9 | 925 | 950 | 1760 | 3.6 | 138 | 500 |
BDAP-80 | 8 | 1024 | 1000 | 1845 | 4 | 160 | 580 |
BDAP-100 | 10 | 1024 | 1000 | 1995 | 5.1 | 200 | 655 |
BDAP-135 | 13.5 | 1024 | 1000 | 2320 | 6.5 | 260 | 690 |
BDAP-170 | 17 | 1200 | 1000 | 2180 | 7.5 | 300 | 840 |
BDAP-220 | 22 | 1332 | 1200 | 2345 | 10.8 | 440 | 1130 |
BDAP-270 | 27 | 1382 | 1200 | 2152 | 14.4 | 570 | 1245 |
BDAP-320 | 32 | 1466 | 1200 | 2150 | 16 | 640 | 1345 |
BDAP-370 | 37 | 1466 | 1200 | 2374 | 18 | 700 | 1510 |
BDAP-450 | 45 | 1633 | 1370 | 2464 | 22.5 | 870 | 1820 |
BDAP-550 | 55 | 1730 | 1400 | 2684 | 27 | 1060 | 2200 |
BDAP-650 | 65 | 1936 | 1400 | 2670 | 34.5 | 1340 | 2790 |
BDAP-850 | 85 | 2236 | 1650 | 2823 | 40.5 | 1600 | 3500 |
BDAP-1100 | 110 | 2280 | 2190 | 3100 | 51 | 2000 | 3840 |
BDAP-1300 | 130 | 2400 | 2200 | 3200 | 57 | 2300 | 4450 |
BDAP-1600 | 160 | 2650 | 2400 | 3400 | 72 | 2900 | 5200 |
BDAP-1900 | 190 | 2738 | 2190 | 3270 | 87 | 3400 | 6100 |
BDAP-2200 | 220 | 3146 | 2540 | 3490 | 111 | 4400 | 7600 |
BDAP-2600 | 260 | 3800 | 3000 | 3800 | 132 | 5200 | 8800 |
BDAP-3000 | 300 | 4000 | 3000 | 3800 | 150 | 6000 | 9700 |
BDAP-4000 | 400 | 4300 | 3200 | 3800 | 201 | 8000 | 14200 |
BDAP-5000 | 500 | 4500 | 3200 | 3800 | 252 | 10000 | 15000 |
air-inlet temperature: 2~50ºC Air-inlet oil carried-over:≤0.1PPM Working pressure: 0.6-1.0MPa Dew point: -20~-40ºC Regenerative air capacity: ≤7% Desiccant: Activated alumina Controls: PLC Installation: Indoor with Anchor bolt. | |||||||
Compression Heat Desiccant Air Dryer | |||||||
Model | Capacitym3/ min | Dimension mm | Cooling water | Desiccant | Weight | ||
L | W | H | circulation T/h | Weight (kg) | (kg) | ||
BCAD-135 | 13.5 | 1800 | 1600 | 2400 | 7 | 0.24 | 1000 |
BCAD-170 | 17 | 2000 | 1600 | 2400 | 8.5 | 0.26 | 1200 |
BCAD-220 | 22 | 2200 | 1600 | 2600 | 11 | 0.33 | 1600 |
BCAD-270 | 27 | 2400 | 1800 | 2700 | 14 | 0.45 | 1800 |
BCAD-320 | 32 | 2400 | 1800 | 2900 | 16 | 0.48 | 2100 |
BCAD-370 | 37 | 2500 | 1900 | 2900 | 19 | 0.56 | 2300 |
BCAD-450 | 45 | 2600 | 2000 | 2900 | 23 | 0.68 | 2700 |
BCAD-550 | 55 | 2600 | 2200 | 3000 | 28 | 0.83 | 3200 |
BCAD-650 | 65 | 2800 | 2400 | 3200 | 33 | 0.98 | 3700 |
BCAD-850 | 85 | 3000 | 2600 | 3200 | 44 | 1.28 | 4500 |
BCAD-1100 | 110 | 3200 | 3000 | 3400 | 55 | 1.65 | 5500 |
BCAD-1300 | 130 | 3400 | 3200 | 3400 | 65 | 1.95 | 6400 |
BCAD-1600 | 160 | 3600 | 3400 | 3400 | 80 | 2.4 | 7500 |
BCAD-1900 | 190 | 3800 | 3600 | 3400 | 95 | 2.85 | 9000 |
BCAD-2200 | 220 | 4000 | 3800 | 3600 | 110 | 3.3 | 10500 |
BCAD-2600 | 260 | 4200 | 4000 | 3800 | 130 | 3.9 | 12000 |
BCAD-3000 | 300 | 4400 | 4200 | 3800 | 150 | 4.5 | 13500 |
BCAD-4000 | 400 | 5000 | 4600 | 3800 | 200 | 6 | 16500 |
BCAD-5000 | 500 | 5600 | 5000 | 3800 | 250 | 7.5 | 20000 |
air-inlet temperature: 120~180ºC Air-inlet oil carried-over:≤0.1PPM Working pressure: 0.6-0.95MPa Dew point: --12~60ºC Regenerative air capacity: ≤1% Desiccant: Activated alumina Controls: PLC Installation: Indoor with Anchor bolt. | |||||||
Combined Type Desiccant Air Dryer | |||||||
Model | Capacitym3/ min | Dimension mm | Water | Desiccant | Weight | ||
L | W | H | Consumption T/h | Weight (kg) | (kg) | ||
BMAD-135 | 13.5 | 1250 | 1350 | 2000 | 1.7 | 260 | 770 |
BMAD-170 | 17 | 1350 | 1500 | 2200 | 2.1 | 340 | 980 |
BMAD-220 | 22 | 1500 | 1600 | 2400 | 2.6 | 440 | 1180 |
BMAD-270 | 27 | 1600 | 1700 | 2500 | 3.2 | 540 | 1400 |
BMAD-320 | 32 | 1680 | 1800 | 2500 | 3.8 | 640 | 1700 |
BMAD-370 | 37 | 1710 | 1850 | 2500 | 4.4 | 740 | 1900 |
BMAD-450 | 45 | 1750 | 1900 | 2650 | 5.4 | 900 | 2150 |
BMAD-550 | 55 | 1850 | 2000 | 2850 | 6.6 | 1100 | 2550 |
BMAD-650 | 65 | 2000 | 2200 | 3000 | 7.8 | 1300 | 2850 |
BMAD-850 | 85 | 2150 | 2300 | 3100 | 10.2 | 1700 | 3100 |
BMAD-1100 | 110 | 2400 | 2600 | 3200 | 13.2 | 2200 | 4250 |
BMAD-1300 | 130 | 2400 | 2700 | 3200 | 15.6 | 2600 | 4950 |
BMAD-1600 | 160 | 2600 | 3100 | 3300 | 19.2 | 3200 | 5500 |
BMAD-1900 | 190 | 2900 | 3500 | 3400 | 22.8 | 3400 | 6400 |
BMAD-2200 | 220 | 3200 | 3700 | 3600 | 26.4 | 4400 | 7700 |
BMAD-2600 | 260 | 3800 | 4200 | 3800 | 31.2 | 5200 | 11500 |
BMAD-3000 | 300 | 4000 | 4500 | 3800 | 36 | 6000 | 12600 |
BMAD-4000 | 400 | 4300 | 4800 | 3800 | 48 | 8000 | 16000 |
BMAD-5000 | 500 | 4500 | 5200 | 3800 | 60 | 10000 | 19000 |
Pressure Lose≤: 0.05MPa Standard Cycle life: 4~8hrs Desiccant life: 3~5years Dew point: -40~60ºC Regenerative air capacity: ≤3% Desiccant: Activated alumina Controls: PLC Installation: Indoor with Anchor bolt. |
Prod Model: | BDAH-2200 |
---|---|
Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
Performance: | Low Noise |
Capacity: | From 0.8~300 M3/Min |