Price: | US $ 350-600/Piece |
---|---|
Trade Terms: | FOB,CFR,CIF |
Min Order: | 1/Piece |
Pay Type: | L/C,T/T,Western Union |
Measure range | Water (20ºC) 6L to 200000L/h, Air (0.1013MPa 20ºC) 0.05m3 to 4000m3/h |
Ratio of measuring range | 10:1 for standard, 20:1 for special |
Accuracy | 1.5 for standard, 1.0 for special |
Temp of mediums | -80ºC to 120ºC for standard type, 400ºC for high temperature type, ≤85ºC for PTFE lining type |
Temp of working environment | -40ºC to 120ºC |
Viscosity of mediums | DN15: η≤5mPa.s(F15.0-F15.4) η≤30mPa.s(F15.5-F15.9) DN25:η≤250mPa.s DN50-DN150:η≤300mPa.s |
LCD display | LCD display with backlight can show instantaneous flow, accumulated flow (positive, negative and net), velocity, working status and etc. |
Prod Model: | HT-036 |
---|---|
Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
Pressure Loss: | 7kpa-70kpa |
Measurement Range: | Water(20ºC):6-200000L/H |
Ratio Of Range: | 10:1 for Standard, 20:1 for Special |
Media Temperature: | Standard: -80ºC~140ºC |
Temperature Of Operation Environment: | H1:-40ºC~100ºC, H2:-80ºC~250ºC |
Connection Pattern: | Standard Flange: |
Cable Interface: | M20*1.5, Pg11, 1/2 NPT |
Power Supply: | Standard:24VDC (10.8VDC-36VDC) |
Output Signa: | Standard: Two Wires System4~20mA |
Protection Level: | IP65 |
Sensor: | Tube/Flange |
Type: | Variable Area Flow Meter |
Measuring Media: | Liquid |
Measuring Principle: | Mechanics |
Accuracy: | Standard 1.5, Special 1.0 |