Shenzhen Airfact Network Environment Co., Ltd. >> Internet Data Center (IDC01)

Internet Data Center (IDC01)

Internet Data Center (IDC01)
Price: US $ 1-2/Piece
Trade Terms: FOB,DDP,FCA
Min Order: 1/Piece
Pay Type: T/T

Product Specifications

Prod Model: IDC01
Markets: North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe
Server Cabinet Size:600x1000x2000mm: Server Cabinet Size:600x1100x2000mm
Server Cabinet Size:800x1000x2000mm: Server Cabinet Size:800x1100x2000mm
Certification: RoHS
Type: Refrigeration Compressor
Usage: Air Conditioner
Control Type: Digital
Display Type: LCD
Material: Stainless Steel

Product Description

1. The cooling of data centers and network rooms has emerged as a significant challenge as the density of computing equipment increases. Server consolidation projects, along with the shrinking physical size of servers and storage systems, have resulted in high power density and high heat density. Even though the typical per-enclosure power consumption in a data center remains on the order of 1 Kw, equipment may be configured that draws over 15 Kw per enclosure. Furthermore, the introduction of high density enclosures into a data center creates the potential for "hot spots" within the room that the cooling system may not be able to address.

2. AIRFACT Ltd provides reliable, energy-saving solutions of air conditioning system for IDC rooms and racks after sever years of developing and on site testing. These solutions could be applied to solve the cooling situation with the high energy-consuming and high power density enclosures. Applying integrating IDC room which contains about 20 racks of the integration system of air conditioners, power distribution, UPS, control system with cabinet and sealing component to decrease the investment and shorten the construction duration dramatically. These products is also suitable for normal low density IDC but with high density zone to solve the central cooling problem. The cooling in row solution is more suitable for the middle and big size of IDC with more than 20 high energy consuming. Such solution could better prevent the mix between cooling air and hot air to increase the cooling efficiency. The module design is also much easier to expand when demanded in the future
AIRFACT IDC cooling solution provides the possibility for the better efficiency and lower costs as the density increasing.

3. Solution for Smaller Data Centers and 'Hot Spots'
If the project owner has knowledge of the IT equipment associated with the planned high-density pod (e. G. Total power requirements, plug requirements, rack U-height requirements and communications cabling requirements), then the owner can easily choose smaller sized pods or smaller data centers. A smaller data centers normally are included standard design components such as air conditioners, power distribution, UPS, control system and racks. Further more, all such components must be expandability and redundancy in module, In addition, standard dimensions play a key role in predictably isolating hot and cold air flows. Standard dimensions include hot / cold aisle widths, rack height, and standard (short) airflow travel distances.

4. Working Principle and Application
This system is integrated with a cluster of IT racks with a high density air conditioning system and high density power distribution system in a premanufactured, pre tested unit. The principle of this system is the capture of Diagram 2 Diagram 3, all IT equipment exhaust air by enclosing the hot aisle, and then immediately cooling this air using a rack-based air conditioner. The capture of the hot air combined with the short air path allows very high density cooling with high efficiency. The performance of this system is completely independent of the site (even in locations where only comfort air is available) and can be installed without a raised floor. Some examples of application are shown in bellowing

5. Function and Characteristics
A. Ensure operational security of the IDC rooms, and energy consumption reduction based on precision monitoring module, powerful Data Acquisition System and performance management system
B. Monitoring items: Voltage, current, three-phase balance, three-phase load capacity, harmonic ratio, statues of branches load and etc.
C. Class C lightning protection
D. RS485 interface
AIRFACT was established in Australia in 1959. The company mainly undertakes precision machining business in its early stage. The company develop and growth rapidly and won a good reputation in the industry within a few years.

In 1964, with the increased in new technology, AIRFACT started involved in air-conditioning manufacturing, and with the establishment of factory producing commercial air-conditioning in Australia, which embarked the development of precision machining and air-conditioning industry.

To be more competitive, AIRFACT cooperated with world's leading German compressor manufacturer BITZER in 1994.

In 2000, AIRFACT has successfully won the tender of air-conditioning system of Sydney Olympic Games, which helped to establish its brand in Australia

In 2003, AIRFACT has moved to Shenzhen Industrial Zone in China as a joint-venture enterprise. The new factory covers an area of 18, 000 square meter including with Office Building, Researching & Development Center, Product Testing Center, Flow Process Line, Pre-treatment Line, Powder Coating Line, Assembly Line and Dormitory etc.

In early 2005, AIRFACT started its trial production. All design, production and testing were according to European Standard and passed the ISO9001 certification.

In 2006, AIRFACT has stepped into precision machining industry. Through continuous improvement in management, AIRFACT can gain a foothold in the industry. With production speed, cost effectiveness, quality and services, AIRFACT is able to set its unique competitiveness in the industry.

In 2008, AIRFACT began its own brand of cabinets and went into international market. AIRFACT cooperated with world's leading air purifier manufacturer, Lifa Air, and provide high quality products to global customers.

In 2009, AIRFACT has developed a heat exchanger and air-conditioner for cabinets and has passed the ISO14001 and CE certificate.

In 2011, AIRFACT has successfully developed High Power Heat Density Internet Data Center which provided total solution for network communication equipment.

Currently, there are over 350 workers with production capacity over 300 million RMB per year.

AIRFACT offers various communication cabinet and related products which are widely used in computer data network, communication network, aerospace system, computer integrated wiring, transmission and distribution, radiated television, receiving system, automatic control system, industrial control system, monitoring system as well as many other fields.

Send your message to this supplier