Categories
Price: | Negotiable/Piece |
---|---|
Trade Terms: | FOB,CFR,CIF |
Min Order: | 10000/Piece |
Pay Type: | L/C,T/T,Paypal,Western Union |
Number of poles | 1p,2p,3p,4p |
Rated current(In) | 6,10, 16,20, 25, 32,40,50,63 |
Tripping curve | B,C,D |
Rated frequency | 50/60Hz |
Rated voltage | 230/400V |
Mechanical life | 10000 |
Installation temperature | no obvious impact and vibration |
Utilization category | A |
Rated limiting short-circuit current | 3000-6000 |
1.Specifications | |||
Standard | IEC/EN 60898-1 | ||
Electrical features | Rated current In | A | 1,2,4,6,10,16,20,25,32,40,50,63 |
Poles | P | 1,2,3,4 | |
Rated voltage Ue | V | 220/380 230/400 240/415 | |
Insulation voltage Ui | V | 500 | |
Rated frequency | Hz | 50/60 | |
Rated breaking capacity | A | 4500/6000/10000 | |
Rated impulse withstand voltage(1.2/50) Uimp | V | 6000 | |
Dielectric test voltage at ind. Freq. for 1min | kV | 2 | |
Pollution degree | 2 | ||
Thermo-magnetic release characteristic | B,C,D | ||
Mechanical features | Electrical life | t | 8000 |
Mechanical life | t | 20000 | |
Contact position indicator | Yes | ||
Protection degree | lP20 | ||
Reference temperature for setting | |||
of thermal element | C | 30 | |
Ambient temperature | C | From -5~+40 | |
(with daily average < 35 ) | |||
Storage temperature | C | -25~+70 | |
Installation | Terminal connection type | Cable /Pin-type busbar | |
Terminal size top /bottom for cable | mm2 | 25 | |
AWG | 18~3 | ||
Terminal size top/bottom for busbar | mm2 | 25 | |
AWG | 18~3 | ||
Tightening torque | N*m | 2 | |
ln-Ibs | 18 | ||
Mounting | On DIN rail EN 60715(35mm)by means fast clip device | ||
Connection | Product Description Provides protection against Short-circuit/Overload current and function of isolation. High breaking current withstand capacity Applicable to terminal and pin/fork type busbar connection Equipped with finger protected connection terminals Fire resistant plastic parts endures abnormal heating and strong impact Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity Independent of power supply and line voltage, and free from external interference, voltage fluctuationFrom top and bottom |
Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
---|---|
Breaking Capacity: | Low Voltage Circuit Breakers |
Operation: | Manual Type |
Speed: | Normal Type Circuit Breaker |
Arc-extinguishing Medium: | Air |
Structure: | MCB |
Certification: | CE |
Poles Number: | 1,2,3,4 |