Categories
Price: | US $ 300/Set |
---|---|
Trade Terms: | FOB,CIF,others |
Min Order: | 1/Set |
Pay Type: | T/T,Western Union,Paypal |
Prod Model: | LRF-2000SS |
---|---|
Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
Main Application: | Wastewater |
Sensor: | Clamp-on/External |
Type: | Ultrasonic Flow Meter |
Measuring Media: | Liquid |
Accuracy: | <1% |
Size: | Dn30-Dn3000 |
Measuring Principle: | Transit-Time Difference |
High Accuracy measuring
Linearity: better than 0.5%, Repeatability: better than 0.2%, Accuracy: better than ±1%
Wide Measuring Range
Several types transducer for selection, measuring pipe size from DN15mm to DN6000mm
Chinese or English menu
Different version UFM can support Chinese or English display, easy to operate
High Reliability
Adopt low voltage, multi-pulse technology to improve accuracy, useful life and reliability
Strong Anti-interference
Dual-balance signal differential receiver/driver circuit to avoid interference of converter, TV tower, high voltage line etc.
Powerful Recording Function
Automatically record the following data: 1. The totalizer data of the last 512 days/128 months/5 years 2. The time and corresponding flow meter of the last 64 times of power on and off events 3. The working status of the last 32 days
2.Main Feature
Item | Performance and Parameter | |
Convertor | Principle | transit-time ultrasonic flowmeter |
Accuracy | Flow: over 1%-2%(battery-powered supply over ±2% ),Heat: over ±2%,Repeatability: over 0.2% | |
Display | 2×20 character LCD with backlight, support the language of Chinese, English and Italy Convertor dimension:170*180*56cm | |
Operation | Support 16 key light touch keyboard and the Simulation keyboard software | |
Signal Output | 1 way 4~ 20mA output, electric resistance 0~ 1K,accuracy0. 1% | |
1 way OCT pulse output( Pulse width 6 ~ 1 0 0 0 ms,default is 2 0 0 ms) | ||
1 way Relay output | ||
Signal Input | 3 way 4~ 20mA input, accuracy 0. 1%,acquisition signal such as temperature, press and liquid level | |
Connect the temperature transducer Pt100, can finish the heat/energy measurement | ||
Data interface | Insulate RS485 serial interface, upgrade the flew meter software by computer, support the MODBUS, METER-BUS etc. | |
Other Function | Automatically remember the previous flew/energy data of 512 days, 128 months and 10 years | |
Automatically remember the previous flew/energy data of 512 days working condition and check it | ||
Automatically remember the previous 32 times power on/off time and flow rate | ||
Special Cable | Twisted-pair cable, generally, the length under 50 meters; Select the RS485 communication. The transmission distance can over 1000m. | |
Pipe Condition | Pipe Material | Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed. |
Pipe Diameter | 25---6000mm | |
Straight length pipe | Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump. | |
Measuring Medium | Type of Liquid | Water (hot water, chilled water, city water, sea water, waste water, etc.); Sewage with small particle content; Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.); Chemicals (alcohol, acids, etc.); Plant effluent; Beverage, liquid food; Ultra-pure liquids; Solvents and other liquids |
Temperature | Standard Transducer: -30--90ºC; High-temperature transducer: -30--140ºC | |
Turbidity | No more than 10000ppm and less bubble | |
Flow rate | 0--±12 m/s | |
Working Environment | Temperature | Main Unit: -20--60ºC |
Flow transducer: -40--160ºC; Temperature transducer: according to the customer's demands. | ||
Humidity | Main Unit: 85% RH; Flow Transducer: Ip67 | |
Power Supply | DC 24V or AC 85-264V | |
Power Consumption | 1.5W |
Wall-mount | Panel-mount | Explosion-proof |
|
|
|
Wall mounted LRF-2000SW | Panel mounted LRF-2000SS | Explosin-proof LRF-2000SD |
4. Optional transducer
Optional Transduers | Model | Measuring Range | Liquid Temperature | Accuracy | |
Clamp-on | TS-2(small size) | LRF-2000SNB1 | DN15-100mm | -40C°90C° | Better than ±1% |
| TM-1(medium size) | LRF-2000SNB2 | DN50-1000mm | ||
TL-1(large size) | LRF-2000SNB3 | DN300-6000mm | |||
High-tem clamp-on | HTS-1(small size) | LRF-2000SNB4 | DN15-100mm | -40C°160C° | |
| HTM-1(medium size) | LRF-2000SNB5 | DN50-1000mm | ||
Insertion | TC-1(standard) | LRF-2000SNC1 | DN80-6000mm | -40C°90C° | |
| TLC-2(lengthen) | LRF-2000SNC2 | |||
Prover Section | Prover Section | LRF-2000SNG | DN15-1000mm | -40C°90C° | Better than ±0.5% |
No matter in past , present or future
We only focus on production of ultrasonic flowmeters
Single minded commitment makes us professional
Solemn promise
Every effort is made to ensure the product is shipped in perfect condition.
All products can be exchanged or returned for any quality problem
100% money back guarantee for any of sold product if it is in original condition
Lifetime free technical and maintenance support
Continuous effort is made to be a most trustable manufacturer!