Categories
Price: | Negotiable/Piece |
---|---|
Trade Terms: | FOB |
Min Order: | 1/Set |
Pay Type: | L/C,T/T |
Prod Model: | K3066I |
---|---|
Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
Voltage generators | ||
Setting Range |
7-phase AC (L-N) | 7 x 0 ... 300 V |
2-phase AC (L-L) | 2 x 0 ... 600 V | |
Power | 7-phase AC (L-N) | 7 x 110VA, at 0 ... 300 V |
2-phase AC (L-L) | 2 x 220VA, at 0 ... 600 V | |
Accuracy |
< 0.07% reading + 0.03% range guaranteed at 0 ... 300 V < 0.02% reading + 0.01% range typical at 0-300V |
|
Resolution | 1mV | |
Current generators | ||
Setting Range |
6-phase AC (L-N) | 6 x 0 ... 30 A |
3-phase AC (2L-N) | 3 x 0 ... 60 A (Group A II B) | |
1-phase AC (3L-N) | 1 x 0 ... 180 A | |
Power | 6-phase AC (L-N) | 6x 450VA , at 0 ... 30A |
3-phase AC (2L-N) | 3x 520VA, at 0 ... 60A (Group A II B) | |
1-phase AC (3L-N) | 1 x 1000 VA, at 0 ... 180A (Max. ) | |
Accuracy |
< 0.07% reading + 0.06% range guaranteed at 0-30A < 0.02% reading + 0.02% range typical at 0-30A |
|
Resolution | 1mA | |
Generators, general | ||
Frequency | Range | 0 ... 1000 Hz |
Accuracy / drift |
Error < 0.001Hz at 10 ... 65Hz, Error < 0.01Hz at 65Hz...450Hz Error < 0.02Hz at 450Hz...1000Hz |
|
Resolution | 0.001Hz | |
Phase | Range | - 360° ... +360° |
Accuracy / drift | Error < 0.2 ° | |
Resolution | 0.1° | |
Timer | Range | Infinite |
Accuracy / drift | Error< 0.1ms | |
DC generators | ||
Voltage ranges | 0 ... 300V/180W | |
Current ranges | 0 ... 20A/300W | |
Accuracy |
< 0.07% reading + 0.03% range guaranteed at 0-300V < 0.04% reading + 0.02% range typical at 0-300V |
|
< 0.14% reading + 0.06% range guaranteed at 0-20A < 0.05% reading + 0.02% range typical at 0-20A |
||
Resolution | 1mA; 1 mV | |
Aux DC Supply | ||
Range | 0...300V/150W | |
Binary inputs | ||
Number | 8 pairs | |
Compatible Voltage | 10V ... 250V DC | |
Binary outputs | ||
Number | 4 Pairs | |
Capacity | 250V/3A AC/DC | |
Synchronization | ||
Synchronization mode | GPS | |
Harmonic | ||
Harmonic overlap times | 2 ... 20 times | |
Power supply | ||
Nominal input voltage | 220VAC± 20% | |
Power | 1000VA | |
Nominal frequency | 47Hz… . 65Hz | |
Environmental conditions | ||
Operation temperature | -5° C ... 55 ° C | |
Storage temperature | -20° C ... 75 ° C | |
Humidity range | 5% ... 90 %, non-condensing | |
Weight | 20 KG | |
Dimensions | 460(D)× 140 (W)× 360 (H) mm | |
PC connection | RJ45, |
Model | Channels | AC Outputs |
K3063i / K3063Li | 10 output channels | 6*30A/3*40A/4*300V |
K3030i / K3030Li | 7 output channels | 3*30A/4*300V |
K3066 | 13 output channels | 6*20A/3*40A/7*130V |
K3063 | 10 output channels | 6*20A/3*40A/4*130V |
K3040 | 7 output channels | 3*40A/4*130V |
K3030 | 7 output channels | 3*30A/4*130V |
Items | IEEE(R) No. |
Synchronization relay | |
Fault transplay | |
GPS Synchronization | |
Overcurrent relays | 50/76 |
Inverse time overcurrent relays | 51 |
Undercurrent relays | 37 |
Ground fault relays | 50 |
Directional overcurrent relays | 67 |
Directional ground fault relays | 67N |
Overvoltage relays | 59 |
Undervoltage relays | 27 |
Directional voltage relays | 91 |
Directional power relays | 32 |
Power factor relays | 55 |
Differential protection (differential circuits) | 87 |
Distance protection equipment (phase by phase) | 21 |
Negative sequence overcurrent relays | 46N |
Motor overload protection | 51/86 |
Automatic reclosing devices | 79 |
Tripping relays | 94 |
Voltage regulating relays | |
Overimpedance relays, Z> | |
Underimpedance relays, Z | |
Time-delay relays |