Yueqing Champn Electric Co., Ltd. >> S10 Power Transformer (S10, S11)

S10 Power Transformer (S10, S11)

S10 Power Transformer (S10, S11)
Price: Negotiable/Piece
Trade Terms: FOB,CIF
Min Order: 1/Piece
Pay Type: L/C,T/T

Product Specifications

Prod Model: S10, S11
Markets: North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe
Phase: Three
Coil: Core-type Transformer
Cooling Method: Oil-immersed Type Transformer
Winding Type: Two-winding Transformer
Application: Electronic

Product Description

Specifications
1.110KV Power Transformer
2. Oil immersed
3. IEC Stndard
4. ISO Certificate
5. Type Test Report
110KV Power Transformer
I. Characteristics:
1.110KV Series Oil immersed Power Transformer has optimized design using advance technologies in order to offer low noise, low partial discharge, high resistance to short cuircuit capacity. Advance design software are used for electromagnetic calculation and design ensure sufficient safety margin during short circuit period. This is based on in-depth theoretical and experimental studies on magnetic, thermal, mechanical strength and short circuit strength. To ensure reliability of the transformer, the insulation are decided based on calculation of the electric field distribution in inner coils will ensure voltage gradient and at coil end it will ensure low partial discharge.
2. Potential distribution is effectively improved by application sofware to calculate the impact and gradient potential distribution. The potential calculation is also done between various parts of the coil including between the coil and coil and earthing.
3. Low Partial Discharge, improves service life.
4. Low noise
Lower the noise level by choosing high quality steel core material, right flux density and the self-vibration frequency of the core, application of high resistance to short-cuicuit of the body structure,
Improves the connection method of tanl and active part.
5. Low temperature rise
Apply reasonable oil flow distribution structure by calculation of oil flow distribution, reduce the winding hot spot temperature rise and the average temperature rise in order to increase overload of each part, extend the life of transformers.
2. Main Technical Specifications
Rated
Capacity
(kVA)
Rated Voltage Connection
Symbol
Loss
(kW)
No-load Current (%) Short-Circuit
Impedance (%)
HV
(kV)
MV
(kV)
LV
(kV)
No-load Load
6300 110±8
×1.25%
35
37
38.5
6.3
6.6
10.5
11
YNyn0
d11
9.6 44.7 0.95
HV-MV
10.5

HV-LV
17~18

MV-LV
6.5
8000 11.5 53.2 0.95
10000 13.7 62.7 0.89
12500 16.2 74.1 0.89
16000 19.4 90.3 0.84
20000 22.9 106.4 0.84
25000 27 126.4 0.78
31500 32.2 149.2 0.78
40000 38.6 179.6 0.73
50000 45.5 213.8 0.73
63000 54.2 256.5 0.67
Our company supplys different kinds of products. High quality and favaroble price. We're pleased to get your Inquiry and we will come back to as soon as possible. We stick to the principle of "quality first, service first, continuous improvement and innovation to meet the customers" for the management and "zero defect, zero complaints" as the quality objective. To perfect our service, we provide the products with the best quality at the reasonable price.