Categories
Price: | US $ 196-256unit |
---|---|
Trade Terms: | FOB,CFR,CIF |
Min Order: | 1unit |
Pay Type: | L/C,T/T,D/P,Paypal,Money Gram |
Prod Model: | R2000W |
---|---|
Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
Input Voltage: | 110V/120V/220VAC/230VAC |
Output Voltage: | 110V/120V/220V/230VAC |
Output Frequency: | 60/50Hz |
Output Current: | 36A/18A |
Color: | Black/Ivory |
Output Wave Form: | Pure Sine Wave |
Dimension: | 442*218*179 Mm |
Weight: | 20kg |
Line Transfer Time: | Typical 4-6ms |
Warranty: | 2 Year |
Phase: | Single |
Type: | DC/AC Inverters |
Output Power: | >1000W |
Power Source: | Solar Power and Utility Power and Generator |
General specifications: | ||||||
Input wave form: | Sine wave(Utility or generator) | |||||
Nominal voltage: | 120VAC | 230VAC | ||||
Low voltage trip: | 90V+/-4% | 184V/154V+/4%- | ||||
Low voltage re engage: | 100V+/-4% | 196V/164+/-4% | ||||
High voltage trip: | 140V+/-4% | 253V+/-4% | ||||
High voltage re engage: | 135V+/-4% | 243V+/-4% | ||||
Max input AC voltage: | 150VAC | 270VAC | ||||
Nominal input frequency: | 50Hz or 60Hz(Auto detect) | |||||
Low frequency trip: | 47Hz for 50Hz, 57Hz for 60Hz | |||||
High frequency trip: | 55Hz for 50Hz, 65Hz for 60Hz | |||||
Output wave form: | (Bypass mode) same as input | |||||
Overload protection: | Circuit breaker | |||||
Short circuit protection: | Circuit breaker | |||||
Transfer switch rating: | 30 amp or 40 amp | |||||
Efficiency on line transfer mode: | 95%+ | |||||
Line transfer time: | 10 ms typical | |||||
Bypass without battery connected: | Yes | |||||
Max bypass current: | 30 amp or 40 amp | |||||
Bypass over load current: | 35 amp or 45 amp: alarm | |||||
Inverter specification/output | ||||||
Output wave form: | Pure sine wave or quasi sine wave | |||||
Output continuous power watts: | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 |
Output continuous power VA: | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 |
Power factor: | 0.9-1.0 | |||||
Nominal output voltage rms: | 120/230VAC | |||||
Output voltage regulation: | +-/10% rms | |||||
Output frequency: | 50Hz+/-0.3Hz or 60Hz+/-0.3Hz | |||||
Nominal efficiency: | >88% | |||||
Surge ratings: | 3000 | 6000 | 9000 | 12000 | 15000 | 18000 |
Short circuit protection: | Yes, fault after 10 secs | |||||
Inverter specification/input: | ||||||
Nominal input voltage: | 12V | 24V | 48V | |||
Minimum start voltage: | 10V | 20V | 40V | |||
Low battery alarm: | 10.5V | 21V | 42V | |||
Low battery trip: | 10V | 20V | 40V | |||
High voltage alarm: | 16V | 32V | 64V | |||
Power saver: | Below 25 watts when enabled | |||||
Power saver: | Same switched on/off on remote | |||||
Charger mode specifications: | ||||||
Input voltage range: | 95-127VAC | 194-243VAC/164-243VAC(W) | ||||
Output voltage: | Dependent on battery type | |||||
Charger current: | 35A /70A | |||||
Battery initial voltage for start up: | 0-15.7V for 12V(*2 for 24V; *4 for 48V) | |||||
Over charger protection shutdown: | 15.7V for 12V(*2 for 24V; *4 for 48V) | |||||
Charger curves (4 stage constant current) battery types | ||||||
4 steps digital controlled progressive charge | ||||||
Battery type: | Fast V | Float V(*2 for 24V; *4 for 48V) | ||||
GEL U.S.A. | 14.0 | 13.7 | ||||
A.G.M. 1 | 14.1 | 13.4 | ||||
A.G.M. 2 | 14.6 | 13.7 | ||||
Sealed lead acid | 14.4 | 13.6 | ||||
GEL Euro | 14.4 | 13.8 | ||||
Open lead acid | 14.8 | 13.3 | ||||
Calcium | 15.1 | 13.6 | ||||
De-sulphation | 15.5 for 4 hrs | |||||
Remote control/RS232/USB | Yes, optional | |||||
Size: in mm | 1000/2000/3000 model: 442*218*179 mm3 | |||||
4000/5000/6000 model: 598*218*179 mm3 | ||||||
Net weight: | 1000 | 2000 | 3000 | 4000 | 5000 | 6000 |
18Kg | 20Kg | 22Kg | 35Kg | 38Kg | 40Kg |