General Service and maintenance Replacement of defective devices Support of commissioning process and installation Performance and efficiency measurement - Evaluation and assessments - Capacity measurement of pumps - Monitoring of regulating valves Energy efficiency audits | Water and waste water industry - hot water, cooling water, potable water, sea water etc.) Petrochemical industry Chemical industry -chlorine, alcohol, acids, .thermal oils.etc Refrigeration and air conditioning systems Food , beverage and pharmaceutical industry Power supply- nuclear power plants, thermal & hydropower plants), heat energy boiler feed water.etc Metallurgy and mining applications Mechanical engineering and plant engineering-pipeline leak detection, inspection, tracking and collection. |
Measurement principle | Ultrasonic transit-time dfference correlation principle |
Flow velocity range | 0.01 to 12 m/s, bi-directional |
Reaolution | 0.25mm/s |
Repeatability | 0.2% of reading |
Accuracy | ±1.0% of reading at rates >0.3 m/s);±0.003 m/s of reading at rates<0.3 m/s |
Resonse time | 0.5s |
Sensitivity | 0.003m/s |
Damping of displayed value | 0-99s(selectable by user) |
Liquid Types Supported | both clean and somewhat dirty liquids with turbidity <10000 ppm |
Power Supply | AC: 85-265V DC: 24V/500mA |
Enclosure type | Wall-mounted |
Degree of protection | IP66 according to EN60529 |
Operating temperature | -20ºC to +60ºC |
Housing material | Fiberglass |
Display | 4 line×16 English letters LCD graphic display, backlit |
Units | User Configured (English and Metric) |
Rate | Rate and Velocity Display |
Totalized | gallons, ft³, barrels, lbs, liters, m³,kg |
Thermal energy | unit GJ,KWh can be optional |
Communication | 4~20mA(accuracy 0.1%),Frequency(1-9999Hz), Relay, RS232, RS485 (Modbus),Logged data |
Security | Keypad lockout, system lockout |
Size | 244*196*144mm |
Weight | 2.4kg |
Degree of protection | IP65. IP67 or IP68 according to EN60529 |
Suited Liquid Temperature | Std. Temp.: -35ºC~85ºC for short periods up to 120ºC |
High Temp.: -35ºC~200ºC for short periods up to 250ºC | |
Pipe diameter range | 20-50mm for type S, 40-1000mm for type M, 1000-6000mm for type L |
Transducer Size | Type S 52(h)*28(w)*26(d)mm |
Type M 60(h)*34(w)*32(d)mm | |
Type L 80(h)*40(w)*42(d)mm | |
Material of transducer | Aluminium for standard temp. sensor,and peek for high temp. sensor |
Cable Length | Std: 10m |
Prod Model: | TF1100-EC |
---|---|
Enter Attribute Here (e.g.: Size): | Enter Value Here (e.g.: 12 Inches) |
Accuracy: | ?à0.6-1% |
Main Application: | Fuel Oil |
Sensor: | Clamp-on/External |
Size: | Dn20-6000 |