Function:
Mainly used in the measurement and digital indication on frequency value in an electric circuit. Switching value output
(higher and lower limit alarms) modules, analog value transmitting output module, RS485 communication module are
Optional offered. It can conveniently realize the setting of many parameters including higher and lower limit alarm value,
Alarm return difference, communication address and communication baud rate, transmitting output specification, transmitting
Output range by the keyboard of instrument.
Basic parameters:
Measuring range: 30.00~99.99Hz
Input voltage: AC 30V~500V
Accuracy rating: ± 0.1Hz
Display resolution: 0.01Hz
Aux. Power Supply(POWER): AC/DC 85~264V
Alarm Output: Relay contact output, contact rating AC250V/1A
Communication interface: RS485 serial communication, applying MODBUS_RTU communication protocol.
Transmitting output: Can be set freely as DC0~10mA, 0~20mA or 4~20mA,
The electrical isolation between the signal input and auxiliary power supply
Transmitting output load resistance: ≤ 400Ω
Switching value input: Two-channel of passive contact input ( can customize four channels)
Terminal arrangement and wiring connection:
( Attention: If it is not the same with the wiring schema of the diagram behind case, please accord to the one of diagram behind case)
POWER: Auxiliary power input port of instrument, Auxiliary power supply is AC 220V± 10% (please note if you need special power supply).
INPUT: Signal input port of instrument, HI represents"+" port of DC input signal, fire wire terminal of AC voltage input signal and inlet wire terminal
Of AC current input signal.
LO: "-" port of DC input signal, the other one wire of AC voltage input signal; The outlet wire terminal of AC current signal input
OUT: The alarm contact output port of meter
Shape
|
Panel dimension
|
Case dimension
|
Hole cutout dimension
|
W
|
H
|
W
|
H
|
D
|
W
|
H
|
120×120suqare
|
120
|
120
|
110
|
110
|
80
|
112
|
112
|
96×96suqare
|
96
|
96
|
90
|
90
|
80
|
92
|
92
|
80×80suqare
|
80
|
80
|
74
|
74
|
80
|
76
|
76
|
72×72suqare
|
72
|
72
|
66
|
66
|
80
|
68
|
68
|
48×48suqare
|
48
|
48
|
44
|
44
|
70
|
45
|
45
|
Technical parameters
Measuring range
|
3.00-99.99HZ
|
Accuracy
|
±0.5%FS±2digit
|
Samping rate
|
About 3 times/sec
|
Overload
|
Consistent:1.2times
|
Measuring display mode
|
RMS measure,4 digit LED nixiettube display
|
Input circuit consumption
|
<0.5VA
|
Auxiliary power
|
AC220±10%,50/60HZ
|
Auxiliary power consumption
|
Wenzhou CNSCKJ Meter Technology Co., Ltd. Specialized in manufacturing various digital display meter, which is member enterprise of the National Electrician instrument& Meter Standardization Committee. The products manufactured by our company strictly complied with IEC 51 publication rev4 issued by international electrician Committee and IEC1010 Standard, and meet the National Standard Requirement GB/T7676-1998. CNSCKJ company have passed through ISO9001: 2000 Certificate and CE Certificate.
(1) We are one of organizations chiefly editing the national standard, Mounted Digital Display Electric Measuring Instrument:
(2)We are involved in the edition of national standards, low-voltage Reactive Power Compensation Switching Device and General Specification for Digital Motor Combined Protection Equipment;
(3)We participate in the revision work of industrial standard, low -voltagea Reactive Power Compensation Control Device
(4) We play an essential role in editing the national standard diagram collections for electrical design, commonly-used Pump Control Circuit Diagram and Commonly-USD Blower Control Circuit Diagram, and the reference diagram collections for eletrical design, Fire-fighting Equipment Power Supply Monitoring System.
Under holding up the enterprise tenet: Survive on quality, Create brand with the credit, CNSCKJ sincerely wish friends at home and abroad to cooperate with for brilliant tomorrow!