Categories
Price: | Negotiable/Piece |
---|---|
Trade Terms: | FOB,EXW,CIF |
Min Order: | 10/Piece |
Pay Type: | T/T,Western Union |
MODEL | HML-8N350-36 | |
OUTPUT | RATED CURRENT | 350mA |
DC VOLTAGE | 3 ~ 36V | |
RATED POWER | 12.6W | |
RIPPLE& NOISE(max. ) Note. 2 | 200mVp-p | |
VOLTAGE TOLERANCE Note. 3 | ± 5.0% | |
LINE REGULATION | ± 1.0% | |
LOAD REGULATION | ± 2.0% | |
SETUP, , RISE TIME Note. 6 | 500ms, 250ms / 230VAC 500ms, 250ms / 115VAC at full load | |
HOLD UP TIME(Typ. ) | 50ms/230VAC 24ms/115VAC at full load | |
INPUT | VOLTAGE RANGE Note. 4 | 90 ~ 264VAC 127 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY (Typ. ) | 75% | |
AC CURRENT | 0.3A/115VAC 0.15A/230VAC | |
INRUSH CURRENT(max. ) | COLD STAR 35A/115VAC 70A/230VAC | |
LEAKAGE CURRENT | 0.25mA /240VAC | |
PROTEC- TION |
CURRENT LIMIT | ± 5% rated output current |
Protection type : Constant current limiting type | ||
OVER VOLTAGE | 27-31V | |
Protection type : Shut off o/p voltage, clamping by TVS diode | ||
ENVIRON-MENT | WORKING TEMP. | -30~+70%(Refer to output load derating curve) |
WORKING HUMIDITY | 20~90% RH-nondensing | |
SHORAGETEMP, HUMIDITY | -40~+80, 10~95% RH | |
TEMP. CONEFFICIENT | ± 0.03%(0~50) | |
VIBRATION | 10~500Hz, 2G 10min. /1 cycle, period for 60min. each long X, Y, Z axes. | |
SAFETY & EMC | SAFETY STANDARDS | UL1310 Class 2, IP67 approved ; design refer to TUV EN60950-1, EN61347-2-13 |
WITHSTAND VOLTAGE | I/P-O/P: 3KVAC | |
ISOLATION RESISTANCE | I/P-O/P: > 100M Ohms / 500VDC / 25 / 70% RH | |
EMI CONDITION & RADIATION |
Compliance to EN55022(CISPR22)Class B | |
HARMONIC CURRENT | Compliance to EN61000-3-2 Class A, EN61000-3-3 | |
EMS IMMUNITY | Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11; ENV50204, EN55024, light industry level, criteriaA | |
OTHERS | MTBF | 732Khrs min. MIL-HDBK-217F (25) |
DIMENSION | 79*36*23mm (L*W*H) | |
PACKING | 0.157Kg; 50pcs/7.85Kg | |
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. |