Kerric (Guangdong) Laboratory Equipment Research and Manufacture Co., Ltd. >> Lab Supplies Fume Hood

Lab Supplies Fume Hood

Lab Supplies Fume Hood
Price: US $ 1500-2850/Piece
Trade Terms: FOB,CFR,CIF
Min Order: 1/Piece
Pay Type: L/C,T/T,Western Union
Lab Supplies Fume Hood Item Name: Fume Cupboard Design Basis: China industrial standardJB/T6412-1999 Shell: 1.2mm thickness high quality cold-rolled steel with 0.5mm thickness of static epoxy resin power coated Lining: Chemical & Heat Resistant, Fire Retardant, Smooth Finish, Easily Cleanable Panels Made out of durable Phenolic integral work walls (5 mm thick). Sash Opening Minimum: 50mm; Maximum: 700mm Average face velocity0.5m/s Front Top Panel Easily openable hinged Top Panel for easy access to Flow Control Valve and Electrical Lighting fixtures for maintenance. Work top: Chemical resistant, splash & spillage proof dished 20mm ORNICES Ceramic Work top with built-in rounded edges rim on all four sides Windows: 5mm toughened glasses Window handle: 1.5mm carbon steel Illumination: 30W fluorescent lamp group, at least 300LUX Sink: Imported PP pool Faucet: Use brass body laboratory faucet with international ceramic valve core featured slowly down water pressure.   Exhaust duct: glass steel tube or PVC tube, corrosion resistance Base: 1.2mm thickness cold rolled steel sheet with 0.5mm thickness of epoxy resin powder finish Socket: 15amp switch with three sockets Technical data: noise: ≤ 60dB (international) Fume Hood Operating Guidelines       .Minimize release of contaminants into the work ara by reducing pedestrian traffic in front of hoods, particularly during hazardous experiments. Also minimize nearby disturbances, such as doors opening or closing, people walking by, and any quick motion in order to prevent cross drafts. Do not block airfoil: Many labs place absorbent paper on the floor of the hood and over the airfoil to catch spills. The airfoil provides airflow across the floor of the hood, especially when the sash is closed. If you use absorbent paper in the hood, please do not block the airfoil. Place bulky equipment away from sidewalls to allow airflow around the equipment. Place any bulky equipment towards the rear of the hood and raise it about 2 inches off the surface with blocks or bricks. This will allow airflow around and under the equipment. Equipment placed near the hood face will cause great variation in airflow. This equipment must be moved towards the rear of the hood, but do not place this equipment against the rear wall of the hood, as it will block airflow to the rear baffles. Work as far inside the hood as possible, at least 4 to 6 inches from the front edge with the sash face between you and task at hand. All equipment should be a minimum of 9-12 inches away from the hood face. Keep sash face clean and clear. To encourage use of sash as added protection against splashes, sprays, etc. keep sash face clean. If sash face must be blocked with paper for certain experiments, please take it down after the experiment is complete. Do not use the hood as a storage cabinet for chemicals or equipment. Materials stored in fume hoods should be kept to a minimum and stored in a manner that will not interfere with airflow. This can be accomplished by equipping the hood with perforated shelves on the side walls and/or allowing at least 3 inch spaces between containers or equipment so air can flow around them to the back exhaust slot. Place any heat-generating equipment in the rear of the hood. Heating devices in the hood produce convection currents that can disrupt airflow. Do not use a hood for any function it was not designed for, such as acid, radioisotopes, etc. The generation of acid vapors requires specially designed fume hoods with wash-down systems. Failure to use a wash-down system will result in the deposit of explosive perchloric acid crystals that may detonate in the hood ductwork. Close sash when finished with hood work or when leaving experiments or chemicals unattended! This simple procedure has contained many fires and explosions within a hood. Certificates:
No.                Fume hood
parameter
KTF _ 1508
1  (L*W*Hmm)size 1500*800*2350
2 (mm)work top height 850
3 (mm)sash opened height 740
4 (mm)operation area (H) 1150
5 (mm)operation area (D) 680
6 (mm)operation area (L) 1280
7 (m3/h)exhaust air 1700
8 (Pa)static press loss less than 90
9 (mm)Exhaust diameter φ 250
10 (m/s)Face Average speed 0.5 ± 10%
11 (dB)Noise less than 65 dB
12 (Lx)work surface illumination 400LUX
13 (V)supply voltage AC 380V/50H z
14 (V)Electric outlet voltage AC 220V/50Hz
15 (A)Electric outlet ampere (current) 13A
16 (kw)adaptation blower power 0.18 ~ 11K w
17 Anti-electric shock protection Class Class I
18 Protection cover class IP40
19 (V)insulation voltage 450VAC
20 (V)impact voltage 6KV
21 net weight(kg) 235
Prod Model: K-S-F-002
Markets: North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe
Size: 1500*800*2350mm
Mateial: All Steel or Steel- Wood
Brand: Kerric
Application: Chemistry, Physics, Biology, Medicine, etc
Kind: Fume Hood
Folded: Unfolded
Usage: Shop, Industrial
Color: as You Require
Concerning design, production, marketing and installation of scientific laboratories, accessories, Kerric covered an area of more than 200 hectares, with standard factory building of 19, 600 square meters. Its Quality System is certified as complying with ISO9001-2000. Occupying an area of more than 200 hectares, with standard factory building of 19, 600 square meters, experience gained in installing hundreds and thousands of laboratories for public and private research and the conformity of products with the principal standards provide a guarantee for the customer. KERRIC has been expanded to further optimize the technology and adapting requirements of tomorrow's laboratory. Contact us today and experience how world-class products, global design experience and a passion for excellence result in truly superior laboratory environments.

Main Business Lines:

Designing, Planing, Integration, Consultation, Manufacturing, Installation & Service for all Laboratory Requirement;

Laboratory Furniture;

Fume Hood, Enclosure & Ventilation Products;

Laboratory Air Flow Control System

Fume Hood and Air Flow Control System Performance, Testing, Calibration & Commisining

Comprehensive Supply of Lab Accessories

We welcome your questions, requests for information and ideas for improving our products and services.