Features:
Compatible with IV sets of any Brand with high accuracy
Automatic calibration for IV sets of any Brand
Three working modes: Drop counting control, Rate control and time control mode
8 Hours internal battery life in high capacity
Has a unique color LCD and an internal battery with a high capability.
Switch between ml/h and drops/min freely
Three levels of alarm volume: High, medium and low
Three levels of Occlusion pressure: High, medium and low
KVO function: When finish the total volume of an infusion, the pump will alarm and enter KVO state.
Specifications:
Controls: Drop counting and adjusting the delivery rate automatically
Pump Type: Peristaltic finger
Applicable IV Sets: Compatible with IV sets of any standard(including lucifugal IV sets)
Accuracy: ≤ 25drop/min: ± 2%, >25drop/min: ± 3% (With the drop counting control mode)
± 5% (With the rate control mode after the correct calibration)
Delivery Rate Range: 1~400drop/min(1drop/min step)1.0ml/h~1200ml/h (1.0ml/h~99.9ml/h, 0.1ml/h step; >99.9ml/h, 1ml/h step)
Delivery Time Range: 1min~1999min (1 min step)
Volume Limit Range: 0~9999ml (1 ml step)
Total Volume Range: 1~9999ml (1 ml step)
Rapid injection: 600ml/h
KVO Rate: 600ml/h
KVO Rate: W hen the delivery rate≤ 10ml/h, KVO is 1 ml/h. O therwise KVO is 3ml/h.
Alarms: Air-in-line, Infusion complete when limited volume has been set, Empty container, Occlusion, Door is open, waiting time Over, No drop been detected, Operational errors, Low battery, other device failures.
Power Supply: AC power supply: AC 100 to 240V± 10%, 50/60Hz;
Internal LI Battery: 11.1V, 2000mAh. 8 Hours of continuous operation on a new fully charged battery with the rate of 20 drops/min.
Power Consumption: ≤ 25VA
Safety level: ClassI, Type BF
Dimensions: 130mm(L)× 200mm(W) × 230mm(H)
Net Weight: Approximately. 2.5kg
Operating Conditions: Ambient temperature: 5 to 40 Relative humidity: 20 to 90%
Storage Conditions: Ambient temperature: -10 to 55 Relative humidity: 10 to 90%
Accessories: AC power line, Operational manual
Flow Rate | 1ml/h~1300ml/h More than 1000ml/h, 1ml/h step Less than 1000ml/h, 0.1ml/h step |
Standard IV SET | ±5% |
Preset infusion volume | 1ml~9999ml More than 1000ml, 1ml step Less than 1000ml, 0.1ml step |
Occlusion sensitivity | Optional choose from higher to lower |
KVO rate | 1 ~5ml/h (adjustable) |
Power supply | 110~220 + 10%, 50~60Hz + 1Hz |
Power consumption | Less than 20VA |
Battery Life | More than 3 hours continuously at 30ml/h with fully charged battery |
Work Condition | Circumstance Temperature: 10 ~40 degree infusion precision will decrease when temperature ≤18 degree Relative Humidity: 30~93% Atmospheric Pressure: 86~106KPa |
Pump dimension (mm) | 233 x146x269 |
Pump weight | About 3kg |
Applicable scope | Fit for mainline, small volume infusion, quick infusion |
Beijing Careshine Technology Co., Ltd. Has been a professional manufacturer and supplier for high-tech medical equipments since 2001.
Careshine's medical equipments have a considerable market share in China domestic market and a growing increase in international market. The quality management system of Careshine is ISO9001 certified and the products are well received by customers for innovative design, reliable quality, competitive prices and rapid & effective customer service.
Careshine aims to build good business relationships with more international distributors and customers sincerely. Careshine assures dealers and clients to continue provide with more state-of-the-art products through sustained efforts in R&D and management.