Heat Recovery Ventilation with Heat recovery
AIR-ERV heat recovery ventilation units , designed for saving energy and also improving indoor air quality.
AIR-ERV heat recovery ventilation units provide heat recovery and well conditioned fresh air by air to air plate type exchanger and heat pump.
30°C fresh air in the summer time and 12°C fresh air in the winter time can be obtained by usual heat recovery units,
but these results are not comfortable. You can cbtain 20°C fresh air in the summer time and
12°C fresh air in the winter with high efficiency heat pump.
? 5 standard models with TSEK certifcation
? Conditioned fresh air, with a temperature of 20°C in summer and 25°C in winter
? Compact structure (fresh air fan + exhaust air fan + plate type heat exchanger +evaporator +
condenser + compressor + cooling equipments)
? High quality indoor air with synthetic filter
? The design, providing fast and easy installation and maintenance
? Low noise level and working on required capacity by using direct driven fan with 5 speeds
? The high conductivity and performance, aluminum plate type heat recovery exchangers
DX Controller is supplied with the heat-pump heat recovery unit as standart.There are 4 different modes;
? FAN mode: Only the fans runs and heat is transferred over the plate heat exchanger. Compressor does not run.
? COOL mode: Compressor runs and cools the air by regarding to the room set temperature.
? HEAT mode: Compressor runs and heats the air by regarding to the room set temperature.
? AUTO mode: The unit runs and operates cooling, heating or only fan by regarding to the room set temperature.
Heat Recovery Ventilation with Heat recovery Size and performance
Model | Air Volume (m3/h) | Static Pressure (Pa) | Volts/Hz | Input Power ( W ) | TemperatureEfficiency ( % ) | Noise [dB(A)] | Dimension (mm) |
High | Low | High | Low | High | Low | High | Low | L | W | H |
HRV-02DT | 200 | 150 | 70 | 75 | 220V/50Hz | 70 | 55 | 77 | 30 | 27 | 665 | 580 | 293 |
HRV-03 DT | 300 | 150 | 50 | 50 | 220V/50Hz | 105 | 75 | 77 | 32 | 29 | 745 | 600 | 293 |
HRV-04 DT | 400 | 250 | 75 | 50 | 220V/50Hz | 155 | 105 | 78 | 34 | 30 | 745 | 800 | 293 |
HRV-06 DT | 500 | 300 | 100 | 70 | 220V/50Hz | 190 | 150 | 76 | 35 | 32 | 820 | 900 | 293 |
HRV-08 DT | 800 | 600 | 120 | 100 | 220V/50Hz | 410 | 295 | 76 | 37 | 35 | 1110 | 880 | 413 |
HRV-10 DT | 1000 | 700 | 80 | 80 | 220V/50Hz | 435 | 330 | 75 | 38 | 36 | 1110 | 1135 | 413 |
XIAMEN AIR-ERV TECHNOLOGY CO. Ltd was founded in 1996,
Specialized in R&D and manufacture air to air heat recovery systems.
The company passed ISO9001: 2008 Quality System Certification, achieved CE certification, and had own patents.
We have 5100 square meter building area and completely self-contained facilities. Right now we not only have own brand "Zhonghui" in China,
"AIR-ERV" in international, but also provide OEM services for many large transnational companies.
We have been in the customers to establish a good reputation at home and abroad.
Since we step into the fresh air energy saving field, we constantly perfect ourself and improve the products structure, so as to satisfied different clients request.
Ventilation system: The Energy Recovery Ventilator, includes KRV and ERV series (Patent number: ZL 03 2 69262.5);
Heat Recovery Ventilator; Cabinet and base station ventilator; And heat exchanger wheels.
Air to Air Heat Exchanger Core: We both have total heat paper core and sensible heat aluminium core.
Which are divided into ERA, ERB, ERC, ERD 4 series, they have different air flow: Crossflow, counter flow and counter&cross flow.