Categories
Price: | US $ 0.1-10/Meter |
---|---|
Trade Terms: | FOB |
Min Order: | 1000/Meter |
Pay Type: | L/C,T/T |
JKLGYJ 10kV 1x120mm2 Overhead Power Distribution abc Stainless Steel Conductor PVC Insulation Cable
Brand Name | Wanma |
Model Number | JKLGYJ 10kV 1x120mm2 |
Model Name | JKLGYJ 10kV 1x120mm2 Overhead Aerial Bundled Cable for Power Distribution |
Manufacturing Standard | IEC60502 |
Core Material | Aluminium |
Core Number | 1 |
Insulation | XLPE |
Rated Voltage | 10kV |
Max. Rated Operating Temperature of Conductor | 90ºC |
Max. Short-circuit Temperature(within 5 secs) | Lower than 250ºC |
Laying Temperature | Over -20ºC ; The cable should be heathed beforehand under -20ºC when laid |
Bending Diameter | For single-core cable:20(D+d)±5%,in millimeter. For mutlicore cable: 15(D+d)±5%,in millimeter. Where D is the actual outer diameter of the cable,d is the actual outer diameter of the conductor. |
Breaking Strength(Cu core cable) | 7*S(N); S is the total crossection area of cable. |
Shipping Way | Shipping or as customer required |
Packing | Wooden drum or Steel drum |
Payment Item | T/T; D/C |
The cable is made by extruding internal screen with waterproof XLPE or black weatherproof high density PE or weatherproof PVC insulation and outer screen over compact Cu or Al conductor.(No internal and outer screen in 1KV aerial insulated cable at rated voltage of 1KV).The cable has excellent mechanical,physical property and electrical property.Simple construction and reliability.It is track resistant and weatherproof.Compared with bare wire; the cable is laying gap is narrow. Which save the line and reduce the voltage drop of line.
Especially, the cable avoid the accident when supplying electricity.
n Application:
The cable is suitable for electricity transmission and distribution of high building,traveling place and places
full of trees.
Application Character:
The type of rated voltage of cable include:a,0.6/1KV; b,10KV; c,35KV
The permissible long-term operating temperature of cable;
for PVC insulation:70ºC
for PE insulation:70ºC
for XLPE insulation:90ºC
Max short-circuit temperature(within 5 secs)
for PVC insulation:160ºC
for PE insulation:130ºC
for XLPE insulation:250ºC
The laying temperature of cable:≥-20ºC
The ambient temperature:-40ºC~+40ºC relative humidity:≤90%
The permissible bending radius of cable:
for cable at rated voltage of 0.6/1KV and below.
When D<25mm.the bending radius is: ≥4D
D≥25mm.the bending radius is:≥6D
The permissible bending radius of cable:
for cable at rated voltage of 10KV,35KV is stipulated as follows:
for single-core cable:20(D+d)±5%
for multi-core cable:15(D+d)±5%
Where:D is the actual outer diameter of cable, in millimeters.
d is the actual outer diameter of conductor, in millimeters.
Type and specification are given in table 1~2
Table 1
Rated voltage | Type | Description | Application |
0.6/1kV | JKV-0.6/1kV JKLV-0.6/1kV JKY-0.6/1kV | 0.6/1KV Cu core PVC insulated aerial cable 0.6/1KV Al core PVC insulated aerial cable 0.6/1KV Cu core PE insulated aerial cable | aerially fixed laid house service wire |
0.6/1kV | JKLY-0.6/1kV JKYJ-0.6/1kV | 0.6/1KV Al core PE insulated aerial cable 0.6/1KV Cu core XLPE insulated aerial cable 0.6/1KV core XLPE insulated aerial cable | aerially fixed laid house service wire |
10kV
35kV | JKYJ JKLYJ JKY JKLY JKLYJ/B | Cu core XLPE insulated aerial cable Al core XLPE insulated aerial cable Cu core PE insulated aerial cable Al core PE insulated aerial cable Al core white colored XLPE insulated aerial cable | When the cable is aerially fixed laid,certain distance shall be kept between the cable and trees.Frequent contacts between cable and trees are permissible when operating cable |
JKLYJ/Q JKLY/Q | Al core light-weight XLPE thin wall insulated aerial cable Al core light-weight PE thin wall insulated aerial cable | When cable is aerially laid,certain distance shall be kept between cable and trees.Only short-time contact is permissible between cable and trees. |
Table 2
Rated voltage | Core number | Nominal cross section |
10kV&35kV | 1,3 | 10-300 |
0.6/1kV | 1,2,3,4 | 16-240 |
Construction Drawing
Nominal Cross-sectional of Conductor | Insulation Thickness | Approx Outer Diameter of Cable | Approx Weight of Cable | Resistance of Conductor | Broken Strength of Cable | |||
Cu | AI | Cu | AI | Cu | AI | |||
mm2 | mm | mm | Kg/Km | Kg/Km | Ω/Km | Ω/Km | N | N |
10 |
|
|
|
|
|
|
|
|
16 |
|
|
|
|
|
|
|
|
25 | 2.5 | 14.0 |
| 150 |
| ≤1.20 |
| 3762 |
35 | 2.5 | 15.0 |
| 200 |
| ≤0.868 |
| 5177 |
50 | 2.5 | 16.3 |
| 250 |
| ≤0.641 |
| 7011 |
70 | 2.5 | 18.0 |
| 320 |
| ≤0.443 |
| 10354 |
95 | 2.5 | 19.8 |
| 410 |
| ≤0.320 |
| 13727 |
120 | 2.5 | 21.2 |
| 490 |
| ≤0.253 |
| 17339 |
150 | 2.5 | 22.8 |
| 600 |
| ≤0.206 |
| 21033 |
185 | 2.5 | 24.4 |
| 710 |
| ≤0.164 |
| 26732 |
240 | 2.5 | 26.2 |
| 880 |
| ≤0.125 |
| 34679 |
300 | 2.5 | 28.8 |
| 1050 |
| ≤0.100 |
| 43349 |
EQUIPMENT FOR PRODUCTION AND TEST
CERTIFICATES OF CE&ISO
Prod Model: | JKLGYJ |
---|---|
Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
Type: | BS-Jklyj |
Rated Voltage: | 0.6/1kv |
Operating Temperature: | 70/90 |
Core Number: | 4 |
Insulation: | PVC/PE/XLPE |
Standards: | IEC 60502 |
Ambient Temperature: | -40~40 |
Laying Temeprature: | Over -20 |
Package: | Drum |
Customized: | Acceptable |
Application: | Overhead |
Voltage: | Low and Medium Voltage Cable |
Current: | AC Cable |
Certification: | Kema |
Insulation Material: | PVC/PE/XLPE |
Sheath Material: | PVC/PE/XLPE |
Model: | BS-Jklyj |
Brand: | Wanma |