Price: US $ 1680-1800/Piece
Trade Terms: FOB,CIF,CIP
Min Order: 1/Piece
Pay Type: T/T

Water Cooled Chiller for Frozen Food

Chiller/water chiller/industrial chiller/cooling machine/water cooling chiller/air cooled chiller
 
We are real manufacturer for industrial water chiller with factory in Shanghai, China!!!
Winday Industrial is a professional industrial water chiller manufacture in Shanghai, China.
Successfully passed ISO9001 certification, CE certification, and has been successfully registered trademark  "WINDAY".

STRONG POINTS:

1
Compressor brand is Copeland USA.Scroll compressor. Or Danfoss/Daikin/Sanyo optional is customer appointed
2Evaporator is plate type or copper shell and tube type,copper tube wall thickness is 0.7mm
3Condenser is  Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger
4Pump and water systems are stainless steel SUS304
5High quality level electronic parts, Schneider/Siemens/LS
6Designed chiller running life 10 years(running 8hr per day), 6 years(running 24hr per day). Warranty 1 year, 24 hours online after-sales servies team
7Environment friendly refrigerant R410a/R407c/R134a, at least using R22
8Plywood export box packing
9OEM available
 


Chiller Features:
1. Equipped with brand new Copeland scroll compressor.
2. Equipped with shell and tube evaporator, instead of coil evaporator. Easy to clean compared with coil type.
3. Condenser is made of high efficient copper and the thickness is 0.7mm.
4. Equipped with Emerson throttle valve and expansion valves, to maximize the cooling ability and ensure high stability;
5. Equipped with high quality pumps, good stability of equilibrium, watertight, ensure stable and sustainable flow of chilled water;
6. Equipped with a stainless steel water tank.
7. Equipped with PUNP full-featured PID microcomputer control system.
8. Equipped with standard protection, including compressor overload protection, compressor overheating protection, pump overload protection, cooling fan overload protection, high-pressure protection for cooling system, low pressure protection for cooling system, too high/too low protection for water flow,  anti-freeze protection, anti-frequent startup protection, power default phase protection, power reverse protection, phase dislocation protection overvoltage protection, low-voltage protection.
9. Reserved pipe connection is easy for installation, Only need to connect the pipe and power supply for machine usage.
10. Equipped with castors for flexible movement and convenient
11. This unit has a single, double or four-machine combination, improve work efficiency of the unit.
12. Optional for cryogenic unit, environmentally friendly refrigerant unit.
Performance characteristics
1 high efficiency and energy saving, the heat transfer coefficient is 6000-8000W/m2.0C.
2 stainless steel manufacture, long service life, can reach more than 20 year
3 change laminar flow is turbulent, improves the heat exchange efficiency, reduces the thermal resistance.
4 heat transfer speed, high temperature (400 DEG C), resistant to high pressure (2.5Mpa).
5 has the advantages of compact structure, small occupation area, light weight, easy installation, saving construction investment.
6 flexible design, complete specifications, practical strong pertinence, save money.
7 conditions of application widely, applicable to large pressure, temperature range and a variety of medium heat exchange.
8 low maintenance cost, easy to operate, the cleaning cycle is long, easy cleaning.
9 the use of nano thermal film technology, significantly increase the heat transfer coefficient.
10 the broad field of application, and can be widely used in factories and mines, thermal power, petrochemical industry, city central heating, food and medicine, electronic energy, light industry machinery and other fields.
Detail specification:
1.Compressor brand is copeland and Danfoss in USA.Scroll compressor.
2.Evaporator is copper shell and tube type,copper tube wall thickness is 0.7mm.
3.Condenser is  Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger
4.Pump is stainless steel.

Water chiller parameters (output tem 3ºC)
Model UNITWD-T 
3WC/S5WC/S6WC/S8WC/S10WC/S12WC/S15WC/S20WC/S25WC/S30WC/S
Cooling capacityBtu32755.2052203.6080523.2081717.40108501.6.40124810.96164629.00227921.60248905.40327210.80
RT2.734.356.706.809.0310.3913.7118.9820.7227.24
Kw9.6015.3023.6023.9531.8036.5848.2566.8072.9595.90
×10³Kcal/h8.3013.2020.3020.6027.3031.4041.3057.5062.9082.60
 Total PowerKW2.504.104.606.407.208.4011.3015.3016.1022.50
Total CurrentA4.407.209.6011.5012.7015.0020.1027.3028.7040.10
       Compressor Qtyset1.001.001.001.001.001.001.001.002.002.00
Input powerKW2.103.504.505.706.407.3010.2013.8014.6020.30
 Operation CurrentA3.706.2088.1010.1011.4013.0018.1024.6026.0036.20
CondenserTypeHigh efficiency copper dry type shell-and-tube heat exchanger 
  Cooling Water FlowL/min30.0052.0066.0081.00110.00122.00164.00221.00248.00330.00
Water Pipe Connectionlnch1'1"1"2"2"2"2"2.5"2.5"3"
  Evaporator Type  Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger 
  Freezing water FlowL/min26.0042.0060.0068.0090.00106.00129.00190.00210.00268.00
Water pipe connectionlnch1"1"1"2"2"2"2"2.5"2.5"3"
Freezing Water PumpType High efficiency,low noise 
Input PowerKw0.370.370.750.750.751.501.501.502.202.20
 Input Currentm0.951.281.361.5813.003.503.503.503.503.50
Lift of Outside of MachineBar9.009.0012.0012.0018.0018.0018.0018.0022.0022.00
 Flow ratel/min100.00100.00100.00200.00200.00200.00360.00360.00650.00650.00
Refrigerant Type R22/R134A/R407C/R410A/R507/R404 
    Water tank Indicating VolumeLiter50.0060.0060.00110.00110.00110.00200.00250.00270.00300.00
Safety protection  high and low pressure protection,overload protection,overtemperature protection,phase sequence protection,etc. 
Dimensions (L*W*H) Lengthmm6708708701300130015001700170018001800
Widthmm450550550650650650650650750750
  Highmm1000100010001350135013501350140014501450
 Total WeightKG130.00160.00170.00300.00350.00430.00730.00800.00900.001150.00

Water chiller parameters (output tem -5ºC)
Model UNITWD-T 
3WC/SM15WC/SM16WC/SM18WC/SM110WC/SM112WC/SM115WC/SM120WC/SM125WC/SM130WC/SM1
Cooling capacityBtu19857.8432141.0438930.9249849.3268785.9278817.20100551.64142007.44157566.16200659.72
RT1.652.683.244.155.736.568.4511.8213.1216.71
Kw5.829.4211.4114.6120.1623.1029.4741.6246.1858.81
×10³Kcal/h5.168.209.8112.5917.5219.8025.3635.8839.6450.55
 Total PowerKW2.764.334.836.267.769.4312.5316.5817.2323.42
Total CurrentA5.108.849.8812.3815.2518.1325.2426.4332.8147.04
       Compressor Qtyset1111111222.00
Input powerkw3.704.205.396.937.8110.9514.9815.6221.8920.30
 Operation CurrentA7.568.9110.7413.6114.6921.8022.9929.3743.6036.20
CondenserTypeHigh efficiency copper dry type shell-and-tube heat exchanger 
  Cooling Water FlowL/min23.1037.3066.0057.1077.6088.30115.60162.10176.60231.10
Water Pipe Connectionlnch1'1"1"2"2"2"2"2.5"2.5"3"
  Evaporator Type  Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger 
  Freezing water FlowL/min17.9028.9060.0045.2062.6071.5091.30129.30143.00182.70
Water pipe connectionlnch1"1"1"2"2"2"2"2.5"2.5"3"
Freezing Water PumpType High efficiency,low noise 
Input Powerkw0.390.580.780.780.781.531.531.531.531.53
 Input Currentm0.951.281.361.5813.003.503.503.503.503.50
Lift of Outside of MachineBar16.0020.0022.0022.0019.0018.0026.0025.0019.0019.00
 Flow ratel/min100.00100.00100.00200.00200.00200.00360.00360.00650.00650.00
Refrigerant Type R22/R134A/R407C/R410A/R507/R404 
    Water tank Indicating VolumeLiter85.0090.0060.00190.00190.00190.00210.00255.00255.00255.00
Safety protection  high and low pressure protection,overload protection,overtemperature protection,phase sequence protection,etc. 
Dimensions (L*W*H) Lengthmm1045104514151415141516651665195019501950
Widthmm740740550860860950950950950950
  Highmm1100110010001100110012001200129011901190
 Total WeightKG130.00150.00220.00230.00310.00360.00450.00650.00750.00850.00

Water chiller parameters (output tem -15ºC)
Model UNITWD-T 
3WC/SM25WC/SM26WC/SM28WC/SM210WC/SM212WC/SM215WC/SM220WC/SM225WC/SM230WC/SM2
Cooling capacityBtu19857.8418458.9222071.2127841.9238214.4043468.8857355.7293147.6086391.84114302.00
RT1.651.541.932.233.183.624.787.767.199.52
Kw5.825.416.818.1611.2012.7416.8127.3025.3233.50
×10³Kcal/h5.164.685.867.129.5410.9814.5023.5022.0028.90
 Total PowerKW3.545.426.177.308.9111.0014.9614.6616.3220.42
Total CurrentA6.807.509.4012.8712.6517.7921.8126.8435.7440.18
       Compressor Qtyset1111111222.00
Input powerkw3.233.905.146.617.429.5213.4614.8018.9220.30
 Operation CurrentA6.558.3411.5911.0116.1518.3723.4032.3036.7436.20
CondenserTypeHigh efficiency copper dry type shell-and-tube heat exchanger 
  Cooling Water FlowL/min22.6024.4066.0037.8050.6057.4074.80116.40114.90149.70
Water Pipe Connectionlnch1'1"1"2"2"2"2"2.5"2.5"3"
  Evaporator Type  Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger 
  Freezing water FlowL/min17.9017.8060.0027.2037.1042.4055.8090.9084.80111.70
Water pipe connectionlnch1"1"1"2"2"2"2"2.5"2.5"3"
Freezing Water PumpType High efficiency,low noise 
Input PowerKw0.390.610.610.780.781.601.601.601.601.60
 Input Currentm0.951.281.361.5813.003.503.503.503.503.50
Lift of Outside of MachineBar16.0020.0022.0022.0019.0018.0026.0025.0019.0019.00
 Flow ratel/min100.00100.00100.00200.00200.00200.00360.00360.00650.00650.00
Refrigerant Type R22/R134A/R407C/R410A/R507/R404 
    Water tank Indicating VolumeLiter85.0090.0060.00190.00190.00190.00210.00255.00255.00255.00
Safety protection  high and low pressure protection,overload protection,overtemperature protection,phase sequence protection,etc. 
Dimensions (L*W*H) Lengthmm1045104514151415141516651665195019501950
Widthmm740740550860860950950950950950
  Highmm1100110010001100110012001200129011901190
 Total WeightKG130.00150.00220.00230.00310.00360.00450.00650.00750.00850.00



Air-cooled chiller parameters(output tem 3ºC)

ModelUNITWD-T 
3AC/S5AC/S6AC/S8AC/S10AC/S12AC/S15AC/S20AC/S25AC/S30AC/S
Cooling capacityBtu28865.5246676.1659780.4072505.0097787.92110548.80144737.04202092.76221029.36289405.84
RT2.43.895.286.048.149.2012.0516.8318.4024.10
Kw8.4613.6818.6021.2528.6632.4042.4259.2364.7884.82
×10³Kcal/h7.2311.7415.9918.3224.6527.8336.6051.0255.6573.05
Total PowerKW3.255.306.068.1010..212.2316.3519.3022.0530.26
Total CurrentA5.339.0611.4014.7118.0520.5429.3637.4340.2956.71
CompressorQty11111111222.00
Input power2.624.355.106.518.569.6213.3816.3219.1526.5220.30
Operation Current4.708.109.9112.7016.0017.7025.9032.6035.0051.7036.20
CondenserTypeEfficiency copper and Blue hydrophilic aluminum Finned heat exchanger 
FansInput powerKw0.260.5266.000.960.961.141.601.521.522.24
Water Pipe ConnectionLnch0.651"2.002"2"2.8"3.5"4.8"4.8"5"
EvaporatorTypeHorizontal shell-and-tube/Coil type high efficiency copper heat exchanger 
Freezing water FlowL/min24.0038.7060.0060.7081.7092.40121.20168.80184.80242.40
Water pipe connectionLnch1"1"1"2"2"2"2"2.5"2.5"3"
Freezing Water PumpTypeHigh efficiency,low noise 
Input PowerKw0.390.580.780.780.781.531.531.531.531.53
Input CurrentM0.951.281.361.5813.003.503.503.503.503.50
Lift of Outside of MachineBar15"20"22"22"20"17"25"24"18"18"
Flow rateL/min100.00100.00100.00200.00200.00200.00360.00360.00650.00650.00
RefrigerantType R22/R134A/R407C/R410A/R507/R404 
Water tank Indicating VolumeLiter85.0090.0060.00190.00190.00190.00210.00255.00255.00255.00
Safety protectionHigh and low pressure protection,overload protection,overtemperature protection,phase sequence protection,etc. 
Dimensions (L*W*H)LengthMm1150115014151505150515051755206020602820
WidthMm740740550850850850900102510251025
HighMm1375137510001475147515501780191019102010
Total WeightKG130.00200'230'350'350"400"420"520"735"1035"
Note:
1, the table refrigeration conditions: cold water inlet temperature 12 ºC, cold water temperature 7 ºC, ambient temperature 35 ºC, the use of ambient temperature range -7 ºC ~ 43 ºC;
2, crew safe operating range: Chilled water inlet temperature 9 ~ 20 ºC;
3, the series unit uses imported from Europe hermetic compressors, superior performance, strong anti-strike capability liquid;
4, standard power supply: 380V / 3N-50HZ, voltage fluctuation allowed ± 10%, frequency fluctuation ± 2%;
5, host the actual head of the pump head minus head losses within the host. (1mH2O = 9.8KPa)
6, In addition to the specifications and requirements, We can provide non-standard products according to customer requirements.

Air-cooled chiller parameters(output tem -5ºC)

Model UNITWD-T 
3AC/SM15AC/SM16AC/M18AC/SM110AC/SM112AC/SM115AC/S M120AC/S M125AC/S M130AC/S M1
Cooling capacityBtu17401.2026681.8429697.3642513.5261279.5268717.6889189.68114165.52136650.60178447.60
RT1.452.222.633.545.105.727.439.5111.3814.86
Kw5.107.829.2412.4617.9620.1426.1433.4640.0552.30
×10³Kcal/h4.386.747.9510.7015.4617.2822.5028.8034.5044.98
 Total PowerKW3.405.327.428.4010.5012.5216.5020.4022.8330.56
Total CurrentA5.339.0611.5014.7118.0520.5429.3637.4340.2956.71
       Compressor Qty11111111222.00
Input powerkw2.784.306.648.839.9213.4617.4019.8326.8520.30
 Operation CurrentA4.848.3912.7215.8617.5024.0529.5935.0048.0936.20
CondenserTypeEfficiency copper and Blue hydrophilic aluminum Finned heat exchanger 
FansInput powerkw0.260.5166.000.960.961.141.601.521.522.24
Water Pipe Connectionlnch0.651"2.002"2"2.8"3.5"4.8"4.8"5"
  Evaporator Type  Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger 
  Freezing water FlowL/min15.7024.3060.0038.7055.8062.3081.30104.00111.50124.50
Water pipe connectionlnch1"1"1"2"2"2"2"2.5"2.5"3"
Freezing Water PumpType High efficiency,low noise 
Input PowerKw0.390.580.780.780.781.531.531.531.531.53
 Input Currentm0.951.281.361.5813.003.503.503.503.503.50
Lift of Outside of MachineBar16"21"17"17"16"18"26"25"25"19"
 Flow ratel/min100.00100.00100.00200.00200.00200.00360.00360.00650.00650.00
Refrigerant Type R22/R134A/R407C/R410A/R507/R404 
    Water tank Indicating VolumeLiter85.0090.0060.00190.00190.00190.00210.00255.00255.00255.00
Safety protection  high and low pressure protection,overload protection,overtemperature protection,phase sequence protection,etc. 
Dimensions (L*W*H) Lengthmm1150115014151505150515051755206020602820
Widthmm740740550850850850900102510251025
  Highmm1375137510001475147515501780191019102010
 Total WeightKG130.00200'230'350'350'410'420'540'735.001035.00
Note:
1, the table refrigeration conditions: freezing glycol water inlet temperature 0 ºC, cold water temperature -5 ºC, ambient temperature 35 ºC, the use of ambient temperature range -7 ºC ~ 43 ºC;
2, this series of units used in low temperature conditions, to use 25% of the glycol for antifreeze coolants;
3, the series unit uses imported from Europe hermetic compressors, superior performance, strong anti-strike capability liquid;
4, standard power supply: 380V / 3N-50HZ, voltage fluctuation allowed ± 10%, frequency fluctuation ± 2%;
5, host the actual head of the pump head minus head losses within the host. (1mH2O = 9.8KPa);
6, In addition to the specifications and requirements, We can provide non-standard products according to customer requirements.

Air-cooled chiller parameters(output tem -15ºC)
Model UNITWD-T 
3AC/SM25AC/SM26AC/M28AC/SM210AC/SM212AC/SM215AC/S M220AC/S M225AC/S M230AC/S M2
Cooling capacityBtu28865.5246676.1625965.3221461.4830946.8435143.6047085.6076155.8470355.4493966.48
RT1.081.792.163.073.644.015.066.688.109.91
Kw3.86.297.6110.812.814.117.823.528.534.9
×10³Kcal/h3.215.216.549.2911.0112.1315.3120.2124.5130.01
 Total PowerKW2.74.305.996.878.28.9012.2016.7317.6923.92
Total CurrentA4.97.908.7111.814.415.921.628.531.042.3
       Compressor Qty11111111222.00
Input powerKW2.624.355.216.997.859.1414.7515.6918.2520.30
 Operation CurrentA4.708.1011.7612.0716.7620.0232.3433.5340.0436.20
CondenserTypeEfficiency copper and Blue hydrophilic aluminum Finned heat exchanger 
FansInput powerkw0.260.5266.000.960.961.141.601.521.522.24
Water Pipe Connectionlnch0.651"2.002"2"2.8"3.5"4.8"4.8"5"
  Evaporator Type  Horizontal shell-and-tube/Coil type high efficiency copper heat exchanger 
  Freezing water FlowL/min21.0038.7060.0021.0030.3134.4645.9774.5668.9391.95
Water pipe connectionlnch1"1"1"2"2"2"2"2.5"2.5"3"
Freezing Water PumpType High efficiency,low noise 
Input PowerKw0.390.580.780.780.780.781.531.531.531.53
 Input Currentm0.951.281.361.5813.003.503.503.503.503.50
Lift of Outside of MachineBar15.0020.0022.0017.0016.0018.0025.0025.0019.0019.00
 Flow ratel/min100.00100.00100.00200.00200.00200.00360.00360.00650.00650.00
Refrigerant Type R22/R134A/R407C/R410A/R507/R404 
    Water tank Indicating VolumeLiter85.0090.0060.00190.00190.00190.00210.00255.00255.00255.00
Safety protection  high and low pressure protection,overload protection,overtemperature protection,phase sequence protection,etc. 
Dimensions (L*W*H) Lengthmm1150115014151505150517551755222022202820
Widthmm7407405508508509001200102510251125
  Highmm1375137510001475147517801780197020702070
 Total WeightKG130.00200'230'350'350'400'450'540'750'1050'
Note:
1, the table refrigeration conditions: freezing glycol water inlet temperature -10 ºC, cold water temperature -15 ºC, ambient temperature 35 ºC, the use of ambient temperature range -7 ºC ~ 43 ºC;
2, this series of units used in low temperature conditions, to use 25% of the glycol for antifreeze coolants;
3, the series unit uses imported from Europe hermetic compressors, superior performance, strong anti-strike capability liquid;
4, standard power supply: 380V / 3N-50HZ, voltage fluctuation allowed ± 10%, frequency fluctuation ± 2%;
5, host the actual head of the pump head minus head losses within the host. (1mH2O = 9.8KPa);
6, In addition to the specifications and requirements, We can provide non-standard products according to customer requirements.
Prod Model: WD-6WS
Markets: North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe
Cooling Capacity: 1-120usrt
Refrigerant Type: R22/R134A/R407c/R410A/R507/R404
Dimensions: 870*550*1000mm
Total Weight: 170kg
Type: Water-Cooled
Certification: SGS
Condition: Used
Winday Industrial is a professional R&D manufacturing and trading company of industrial refrigeration equipment and refrigeration system design, installation and service. Foreign trading started in June 2012, and producing plant located in Jinshan Industrial Park, covering an area of 5, 000 square meters. "Wen Dai" takes the word from a famous poet "Reach the top and hold all mountains in a single glance, " which describing Mount Tai of Shandong province, representing company aim "making progress & ensuring stability", also on behalf of product quality performance "efficient stability, progressive energy saving". Equipment manufacturing process achieves excellence, strict control and examination; Refrigeration program design achieves repeated research, experiment, scrutiny, feasibility studies, and strive to provide customers with an optimized cooling system integration solutions and equipment.

Products include industrial refrigeration units: Water-cooled chillers, air-cooled chillers, water (air) coold cryogenic chillers, water-cooled screw unit high energy efficiency, air-cooled screw unit, screw-type cryogenic refrigeration units, water source heat pump units, efficient heat pump, screw-type heat recovery units, inverter air-cooled industrial chillers, industrial chillers integration.

Currently, Winday Industrial has become a business partner of a major national research institutions, renowned universities, Fortune 500. Chillers are widely used in chemical industry, chemical fiber, plastics, food, pharmaceutical, military, printing, plant thermostat, water land source use, and other industries.

Winday Industrial has successfully passed ISO9001 certification, CE certification, and registered trademark "", "WINDAY".

Send your message to this manufacturer

  • Shanghai Winday Industrial Co., Ltd.

More >

Other Products From This Manufacturer