Categories
| Supplier: | Yueqing Sunwor Electric Co., Ltd. |
|---|---|
| Price: | Negotiable |
| Min Order: | 1 /Piece |
| Quantity:: | |
| Trade Terms: | FOB |
|
|
| Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
|---|---|
| Certification: | CE |
| Warranty: | 2 Years |
| Output Type: | Single |
| Output Power: | 101 - 200W |
| Input Voltage: | 110-220V |
| Voltage Regulating Mode: | Frequency Modulation Type |
| Starting Mode: | Self-excited Switching Power Supply |
| Connection Mode: | Series Switching Power Supply |
| Power Supplying System: | Terminal Power Distribution Equipment |
| Model | DR-120-12 | DR-120-24 | DR-120-48 | |
| OUTPUT | DC Voltage | 12V | 24V | 48V |
| Voltage Tolerance | ± 2% | ± 1% | ± 1% | |
| Rated Current | 10A | 5A | 2.5A | |
| Current Range | 0-10A | 0-5A | 0-2.5A | |
| Rated Power | 120W | 120W | 120W | |
| Ripple & Noise | 100mVp-p | 150mVp-p | 240mVp-p | |
| DC Adjustment Range | ± 10% | ± 10% | ± 10% | |
| Setup, Rise Time | 1000ms, 60ms/230VAC at full load1800ms, 60ms/115VACat full load | |||
| Hold Time | 60ms/230VAC12ms/115VAC at full load | |||
| INPUT | Voltage Range | 85-264 VACselected by switch 47-63 Hz, 120-370VDC | ||
| AC Current | 2.6 A/115 V 1.6A/ 230 V | |||
| Efficiency | 81% | 82% | 83% | |
| Inrush Current | Cold start 20A/115V 40A/230V | |||
| Leakage Current | < 1mA/240VAC | |||
|
PROTE CTION |
Over Load | 105%-150% | ||
| Protection type: Shut down O/P voltage, recovers automatically after fault condition is removed | ||||
| Over Voltage | 120%-140% | |||
| Protection type: Shut down O/P voltage, recovers automatically after fault condition is removed | ||||
|
ENVIRON MENT |
Working Temp., Humidity | 10& ordm; C-+60& ordm; C, 20%-90 %RH | ||
| Storage Temp., Humidity | -20& ordm; C-+85& ordm; C, 10%-95 %RH | |||
| Vibration | 10-500Hz, 2G 10min. /1cycle, period for 60min, each along X, Y, Z axes | |||
| SAFETY | Withstand Voltage | I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC | ||
| Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC | |||
| STANDARD | Safety Standard | Design refer to UL508, TUV EN60950-1 | ||
| EMC Standard | Design refer to EN55011, EN55022, EN61000-3-2, -3, EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2 | |||
| NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25& ordm; C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |
|||