Categories
| Supplier: | Chance Electric Limited |
|---|---|
| Price: | US $ 5.8/Piece |
| Min Order: | 1/Piece |
| Quantity:: | |
| Trade Terms: | FOB,CFR,CIF |
|
|
| Prod Model: | S-75W-12V |
|---|---|
| Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
| Certificate: | CE. RoHS |
| Output: | 12V |
| OEM: | Yes |
| Size: | 159*98*38mm |
| Testing Time: | 24 Hours |
| Output Type: | Single |
| Output Power: | 51 - 100W |
| Input Voltage: | 110-220V |
| Voltage Regulating Mode: | Frequency Modulation Type |
| Connection Mode: | Series Switching Power Supply |
| Starting Mode: | Self-excited Switching Power Supply |
| Warranty: | 2 Years |
| Power Supplying System: | Level 1 Power Distribution Equipment |
| Certification: | RoHS |

| Model | S-75-5 | S-75-12 | S-75-15 | S-75-24 |
| DC output voltage | 5V | 12V | 15V | 24V |
| Output voltage rang(Note:2) | ±2% | ±2% | ±1% | ±1% |
| Rated output current | 15A | 6.3A | 5A | 3.1A |
| Output current range | 0-15A | 0-6.3A | 0-5A | 0-3.1A |
| Wave and noise(Note:3) | 70mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
| Inlet stability(Note:4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% |
| Load stability(Note:5) | ±1% | ±0.5% | ±0.5% | ±0.5% |
| DC output power | 75W | 75.6W | 75W | 74.4W |
| Efficiency | 71% | 78% | 78% | 82% |
| Adjustale range for DC voltage | +10%,-5% | +10% | +10% | +10% |
| Input current | 1.6A/115V 0.8A/230V | |||
| AC Inrush current | Cold-start current 30A/115V 60A/230V | |||
| Leakage current | <3.5mA/240VAC | |||
| Overload protection | 115%~135% Type: pulsing hiccup shutdown Reset: auto recovery | |||
| Temperature coefficient | ±0.03%/°c(0~50°c) | |||
| Setup, rise, hold up time | 200ms, 100ms, 30ms/115V 300ms, 50ms, 80ms/230VAC | |||
| Vibration | 10-500Hz, 2G 10min,/1cycle, Period for 60min, Each axes | |||
| Withstand voltage | Input and output internal 1.5KVAC, Input and enclosuer 1.5 KVAC, Output and enclosuer 0.5 KVAC | |||
| Working temperature and humidity | -10°c~+60°c, Refer to output derating curve, 20%~90% RH | |||
| Store temperature and humidity | -20°c~+85°c, 10%~95%RH | |||
| Weight | 0.5Kgs | |||
| Satety standards | UL 1012 TUV EN6050(IEC, UL 1950) Approved | |||
| EMC standards | CISPR22(EN55022), IEC801-2,3,4 IEC555-2 Verfication | |||
| Note: 1. The testing condition for the parameter above is: 230VAC input, rated load, 25°c 70% RH.Temperatuer. 2. Error: include the setting error, line stability and load stability.(Note:5). 3. Wave test: adopting "A12" double wire for 20 MHz, and 0.1 UF&47UF capacitor short-circuit for interrupting. 4. Inlet voltage stability test: wht is overload, the lowest voltage of inlet is up to the highest voltage. 5. Load stability test: The load is from 0% to 100%. | ||||
Manufacturers Directory | Hot Products | China Products | Companies List| Resources Directory | News | Sitemap | Disclaimer | About Us | Contact Us | Cautop|
Copyright 2003-2024 China Manufacturer Directory.