Zhejiang KRIPAL Electric Co., Ltd. >> 400A 300mA Earth Leakage Circuit Breaker

400A 300mA Earth Leakage Circuit Breaker

400A 300mA Earth Leakage Circuit Breaker
Supplier: Zhejiang KRIPAL Electric Co., Ltd.
Price: Negotiable/Piece
Min Order: 100/Piece
Quantity::
Trade Terms: FOB,CFR,CIF
contact supplier

Product Specifications

Prod Model: UKM30L-400S
Markets: North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe
Samples: Provided
Arc-extinguishing Medium: Air
Breaking Capacity: Low Voltage Circuit Breakers
Poles Number: 3
Certification: CCC
Operation: Manual Type
Installation: Fixed
Speed: High-Speed Circuit Breaker
Structure: Earth Leakage Circuit Breaker

Product Description

Earth Leakage Circuit Breaker - ELCB

Prouduct Description:

Rated current In(A): 250, 300, 350, 400,

Number of poles: 3, 4

Rated voltage Ue(V): AC690

Arc distance(mm): 0

Rated limit short capitily lcu/lcs(KA): 50/25

Rated residual actuation: 1/2LΔ N

Rated residual short capitily lcu/lcs(KA): 1/4lcu

Rated residual operation current (non delay): 30mA, 300mA, 500mA (adjustable)



The Earth Leakage Circuit Breaker can be used in the electric power system of AC 50Hz, rated voltage up to 400V, rated current up to 400A for the distribution of power, protection against faults such as overload, short circuit, Leakage etc. As well as control of infrequent operation of motor.

For the function of protection against leakage (of residual current), this Earth Leakage Circuit Breaker can indirectly protect people against the fatal danger of getting electric shock. It can also prevent from fire disaster due to permanently existing ground fault but not being checked up with overcurrent protection device.

For both rated value of residual action current and leakage protection actuation time are adjustable, the breaker can be used in the power distribution system serving as optional protection when leakage occurs.

The CEarth Leakage Circuit Breaker can also serve as protection unit against direct contact when rated residual current is set at 30mA and the relevant protection unit doesn't work.


Founded: In 1987;

People of the staff: 500;

Engineers: More than 30

QA/QC: More than 20

Certificate: CCC, CB, CE, UL, TUV, Semko, KEMA, SAA, ISO9001

The land space of the company: Amounts to 20000m2

What we do: Products' Design, mold building, production of parts (injection & punching), assembling, and products' Inspection

Main products: Isolator switch, changeover switch, waterproof switch socket, industrial plug socket, cable float level switch, terminal junction box, solar photovoltaic inverter, circuit breaker contactor relay and etc.

Main market: Europe, Australia, Middle-east, Asia, Southeast Asia, America, Africa

Send your message to this manufacturer

  • Inquiry about 400A 300mA Earth Leakage Circuit Breaker

Other Products From This Manufacturer