Product Specifications
Prod Model: |
AA1700 |
Markets: |
North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
Product Description
Intech Technologies
AA1702 atomic absorption spectrophotometer
Intech technologies is specialized in manufacturing Atomic absorption spectrometry. Our core R&D staff are composed of senior product engineer and application engineer with decades of experience in related field. We keep abreast of the latest technology in analytical science, dedicating in continuously providing more customized Atomic absorption spectrometry of all kinds, which creates popularity among customers.
The current 1702 series product is upgraded based on Agilent Technologies 4510. Main models includ 1702 Flame Atomic Absorption Economical Model; 1702 Flame Atomic Absorption Standard Model; 1702 Multi-element rapid analysis Atomic Absorption Spectrometry, 1702 Graphite Furnace Atomic Absorption Spectrometry, etc. We also provide portfolio of different models upon customer requirements.
Atomic absorption spectrometry, as an important means of measuring trace metallic elements, is characterized by its high sensitivity, veracity, and speediness in making analysis. It's widely used in the fields of biology, food, geology, metallurgy, construction, material science, medicine, environment, petrol chemical, etc.
Products
1702 Multi-element rapid analysis Atomic Absorption Spectrometry
² 4-6 elements can be analyzed simultaneously within one minute, close to ICP speed. Get the result for multi-element upon one sample introduction.
² Independent assortment of test elements, all according to the requirement of the analysis
² Require fewer samples in doing fast analysis.
² Quickly alters gas-flow rate, rotates grating, slit, and element lamp
² The outstanding mechanical and optical system, together with highly functional software, assures the veracity of the measuring
² High stability, broad measuring range, low lower limit, high resolution, high sensitivity
1702 Graphite Furnace Atomic Absorption Spectrometry
u Smallest size among all instrument of the same kind. 700*550*440
u Flame and Graphite Furnace work simultaneously, no need to cut over.
u High precision sample introduction of the Graphite Furnace.
u The flexible dilution system simplifies enormously the operation, enhances efficiency.
u The stable graphite furnace atomization system, applies the PID technology, makes the temperature control more precise.
u Advanced and secured protection system, guaranties the securities of all operating stuff.
1702 Flame Atomic Absorption Spectrometry
u Outstanding stability
u Secured flame system, gas fuel automatically switched off in abnormal situations
u Highly efficient atomization system enhances sensitivity
u The design of all-in-one suspension light path ensures the stability of the optical system.
u Elimination of dual background
u Powerful data processing, more humanized operation interface
Specifications
Mainframe specification |
Optics | Optical single beam |
Wavelength range | 190 to 900 nm |
Mounting | Aberration-corrected Czerny-Turner mounting |
Wavelength accuracy | ±0.2nm |
Wavelength repeatability | ±0.1nm |
Bandwidth | 0.1, 0.2, 0.4,0.7,1.0,2.0 nm (6-step automatic switching) |
Number of HC Lamps | 6-lamp turret(1 for measurement, 4 warming up for next measurement) |
Photometric Mode | Flame&Furnace: Optical single beam. |
Background Correction | High-speed self-reversal method (BGC-SR), high-speed deuterium lamp method (BGC-D2) |
Burner Type | Water-cooled type |
Burner Head | Pure Titanium |
Gas Control - Flow rate/pressure unit | Automatic control and automatic optimization |
Gas Control - Safety Measures | Automatic gas leak check Flashback prevention through gas pressuring monitoring Prevention of raw gas release when the flame dies out |
Software | Software based on Microsoft WindowsTM |
Dimensions & Weight | 700 (W) x 420 (H) x 550 (D) mm, 103 kg (including gas controller, excluding PC and peripherals) |
Power Requirements | AC220, V±10%,50HZ without sharp voltage fluctuations |
Ambient Temperature and humidity range | Temperature: 10 ~ 35°C Humidity: 45% ~ 80% (less than 70% when temperature is greater than 30°C) |
Flame atomic system |
RSD | ≤0.5% |
Characteristic Concentration (Cu) | 0.025μg/ml/1% |
Detection limit(Cu) | 0.004μg/ml |
Atomizer | Efficient glass atomizer |
Graphite furnace atomic system |
RSD | ≤3% |
characteristic quantity(Cd) | 1.0X10-12g |
Detection limit(Cd) | 2.0X10-12g |
Max speed of heating | 2000ºC/S |
Atomization temperature | 3000ºC |
Graphite furnace protection | Short gas,over heating,Current is too large to immediately stop the heating and alarm |
Power | 220V, V±10%,7000W |
Dimension & weight | 280 x 550 x 450 mm ,80kgs |
Graphite furnace visual system |
Built-in miniature camera, Observable sample position in the graphite tube,Dry,ashing,atomization process. |
Sample injection system(Autosampler) |
Sample | 85 vials |
Cup material | Polypropylene |
Standard vails volume | 2mL,10mL |
Injection volume | 1µL-50µL |
Injection RSD | When volume ≥10µL,RSD≤1% |
Min increment | 1µL |
| | |
Standard configuration:
Sr.No. | Product name | Model | Qty |
1 | AA1702 Atomic absorption spectrophotometer | Standard model | 1 |
2 | Graphite furnace controller | Optional | 1 |
3 | Graphite furnace autosampler | Optional | 1 |
4 | Air compressor | Zero oil | 1 |
5 | HCL | Cu | 1 |
6 | Software worksation | Neutral | 1 |
7 | Mistorizer | | 1 |
8 | Burner | 100mm | 1 |
9 | Acetylene regulator | | 1 |
10 | Oxygen regulator | | 1 |
11 | Acetylene tubing | 10M | 1 |
12 | Graphite pipe | | 2 |
13 | Pipettpor | | 1 |
14 | Tools(screwdriver,wrench etc.) | | 5 |
15 | Sealing ring | | 8 |
16 | Beam-focusing board | | 1 |
17 | Data line | | 1 |
18 | Power cord | | 1 |
19 | Fuse | | 7 |
20 | Effluent tubing | | 1 |
21 | Vials | | 200 |
22 | User manule | | 2 |
23 | Power socket | | 1 |
Intech technologies
Professional OEM Supplier in China
International trading department
Wangbin ( Eli )
Mobile:0086-15168623277/18857667708
Tel:0086-0576-85175877
FAX:0086-0576-85175877
Web:www.chnintech.com
Intech Technologies Specialized in industrial process control valves, Ultra pure gas analysis system control valves, Gas preparation control valves, gas distributor, Sampling analysis system design and manufacture; As well as the laboratory instrument with high middle and low pressure gas regulator valve series, Steady flow of gas valve, gases switch, on-off, sample gas storage, purification device, Special gas path, Design and manufacture of standard gas path, etc. According to user requirements, can be on behalf of pneumatic system design or improve the function.
The company is located in coastal city---- Linhai city toumen port industrial zone, Adjacent to the magic beautiful yandang mountain; Have expressway to wear, closer to several airport, traffic is very convenient.
The company relies on a solid industry foundation and pragmatic business philosophy, can provide customers with quality products and warm service; At the same time sincerely welcome customers to visit, guidance, design of processing, calm brand processing; Welcome all the trial project commissioned and industrialization collaboration of scientific research colleges and universities; Company is willing to work with friends at home and abroad to create, development together.