Categories
| Supplier: | Wuxi Taiwei Electronics Co., Ltd. |
|---|---|
| Price: | Negotiable/Piece |
| Min Order: | 1/Piece |
| Quantity:: | |
| Trade Terms: | FOB |
|
|
| Prod Model: | Aluminum Electrolytic Capacitor LP Snap-in |
|---|---|
| Life: | 2000 Hrs |
| Type: | Aluminum Electrolytic Capacitor |
| Package Type: | Through Hole |
| Capacitance: | >100uf |
| SPECIFICATIONS Aluminum Electrolytic Capacitor | ||||||||||||
| Item | Performance Characteristics | |||||||||||
| Operating Temperature Range | -40 to + 85°C | -25 to + 85°C | ||||||||||
| Rated Voltage Range | 10 to 100 VDC | 160 to 450 VDC | ||||||||||
| Capacitance Range | 410 to 68000 μF | 41 to 2100μF | ||||||||||
| Capacitance Tolerance | ±20% (120Hz, +20°C) | |||||||||||
| Leakage Current (+20°C, max) |
1≤0.02 CV After 5 minutes with rated working voltage applied |
|||||||||||
|
Dissipation Factor (tanδ, at 20°C, 120Hz) |
Less than the value under table (%) | |||||||||||
| μF \ VDC | 10-16 | 25-35 | 50-63 | 80-100 | 160-250 | 315-450 | ||||||
| 41-390 | - | - | - | - | 15 | 20 | ||||||
| 410-3900 | 25 | 20 | 20 | 20 | 15 | 20 | ||||||
| 4100-8200 | 35 | 30 | 30 | 25 | - | - | ||||||
| 10000-22000 | 40 | 35 | 30 | - | - | - | ||||||
| 21000-41000 | 45 | 40 | 35 | - | - | - | ||||||
| 56000-68000 | 50 | 45 | - | - | - | - | ||||||
|
Low Temperature Characteristics (at 120Hz) |
Impedance ratio max | |||||||||||
| Rated voltage (VDC) | 10 | 16 | 25 | 35 | 50 | 63 | 100 | 160 | 200-250 | 400-450 | ||
| Z-25°C / Z+20°C | 5 | 5 | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 8 | ||
| Z-40°C/ Z+20°C | 15 | 15 | 15 | 12 | 12 | 12 | 12 | - | - | - | ||
|
Load Life |
Test conditions Duration time :2000 Hrs Ambient temperature :+85°C Applied voltage :Rated DC working voltage After test requirement at +20°C Capacitance change :≤±20% of the initial measured value Dissipation factor :≤200% of the initial specified value Leakage current :≤The initial specified value |
|||||||||||
| Shelf Life |
Test conditions Duration time :1000 Hrs Ambient temperature :+85°C Applied voltage :None After test requirement at +20°C :Same limits as Load life. Pre-treatment for measurements shall be conducted after application of DC working voltage for 30 minutes |
|||||||||||
| Other | JISC-5141 EIAJ RC-2312 | |||||||||||
| MULTIPLIER FOR RIPPLE CURRENT VS. FREQUENCY | |||||
| CAP(μF)\Frequency(Hz) | 50(60) | 120 | 1K | 10K | 5K ~ 100K |
10|
0.8 |
1 |
1.36 |
1.48 |
1.53 |
|
100|
0.8 |
1 |
1.25 |
1.35 |
1.38 |
|
1000|
0.8 |
1 |
1.11 |
1.25 |
1.28 |
|
Manufacturers Directory | Hot Products | China Products | Companies List| Resources Directory | News | Sitemap | Disclaimer | About Us | Contact Us | Cautop|