| Supplier: | Wuxi Taiwei Electronics Co., Ltd. |
|---|---|
| Price: | Negotiable/Piece |
| Min Order: | 1/Piece |
| Quantity:: | |
| Trade Terms: | FOB |
|
|
| Prod Model: | Aluminum Electrolytic Capacitor LR Radial |
|---|---|
| Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
| T: | Aluminum Electrolytic Capacitor |
| Type: | Aluminum Electrolytic Capacitor |
| Package Type: | Through Hole |
| SPECIFICATIONS Aluminum Electrolytic Capacitor | |||||||||
| Item | Performance Characteristics | ||||||||
| Operating Temperature Range | -40 to + 105°C | ||||||||
| Rated Voltage Range | 6.3 to 50 VDC | ||||||||
| Capacitance Range | 0.47 to 6800 μF | ||||||||
| Capacitance Tolerance | ±20%(120Hz, +20°C) | ||||||||
| Leakage Current (+20°C, max) |
1≤0.01 CV or 3 (μA) After 2 minutes whichever is greater measured with rated working voltage applied |
||||||||
|
Dissipation Factor (tanδ, at 20°C, 120Hz) |
Working Voltage (VDC) | 6.3 | 10 | 16 | 25 | 35 | 50 | ||
| D.F. (%) max | 18 | 16 | 14 | 12 | 10 | 9 | |||
| For capacitance > 1000μF, add 2% per another 1000μF | |||||||||
|
Low Temperature Characteristics (at 120Hz) |
Impedance ratio max | ||||||||
| Working Voltage (VDC) | 6.3 | 10 | 16 | 25 | 35 | 50 | |||
| Z-25°C/ Z+20°C | 4 | 3 | 3 | 3 | 3 | 3 | |||
| Z-40°C / Z+20°C | 8 | 6 | 4 | 3 | 3 | 3 | |||
|
For capacitance > 1000μF, add 0.5 per another 1000μF for - 25°C/ +20°C add 1 per another 1000μF for -40°C / +20°C |
|||||||||
| Load Life | Test conditions | Dφ | Life hours | ||||||
| Duration time :as right | 5-6.3φ | 1000 | |||||||
| Ambient temperature :+105°C | ≥8φ | 2000 | |||||||
|
Applied voltage :Rated DC working voltage After test requirement at +20°C Capacitance change :≤±20% of the initial measured value Dissipation factor :≤200% of the initial specified value Leakage current :≤The initial specified value |
|||||||||
| Shelf Life |
Test conditions Duration time :1000 Hrs Ambient temperature :+105°C Applied voltage :None After test requirement at +20°C :≤200% of the initial specified value Pre-treatment for measurements shall be conducted after application of DC working voltage for 30 minutes |
||||||||
| Other | JISC-5141 EIAJ RC-2372 | ||||||||
| MULTIPLIER FOR RIPPLE CURRENT VS. FREQUENCY | ||||||
| CAP (μF) \ Frequency (Hz) | 50 (60) | 120 | 400 | 1K | 10K | 50K ~ 100K |
| CAP≤10 | 0.47 | 0.59 | 0.76 | 0.85 | 0.97 | 1 |
10|
0.52 |
0.62 |
0.80 |
0.89 |
0.97 |
1 |
|
100|
0.58 |
0.72 |
0.84 |
0.90 |
0.98 |
1 |
|
1000|
0.63 |
0.78 |
0.87 |
0.91 |
0.98 |
1 |
|