| Supplier: | Beijing Beifen-Ruili Analytical Instrument (Group) Co., Ltd. |
|---|---|
| Price: | Negotiable |
| Min Order: | 1 /Piece |
| Quantity:: | |
| Trade Terms: | EXW |
|
|
| Prod Model: | WFX-110B/120B/130B |
|---|---|
| Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
| Main Specification | Wavelength range | 190-900nm |
| Wavelength accuracy | ± 0.25nm | |
| Resolution | Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%. | |
| Baseline stability | ≤ 0.004A/30min | |
| Background correction |
The D2 lamp background correction capability at 1A is better than 30 times. The S-H background correction capability at 1.8A is better than 30 times. (only for WFX-110B/120B) |
|
| Light Source | Lamp turret |
6-lamp turret (WFX-110B/120B), 4-lamp turret (WFX-130B) auto alignment, fully automated scan and peak-picking. |
| Lamp current adjustment |
Automatic adjustment and display. Wide pulse current: 0~25mA, Narrow pulse current: 0~10mA |
|
| Lamp power supply mode |
400Hz square wave pulse 100Hz Narrow square wave pulse + 400Hz wide square wave pulse (WFX-110B/120B) |
|
| Optical System | Monochomator | Single beam, Czerny-Turner design grating monochromator |
| Grating | 1800 l /mm | |
| Focal length | 277mm | |
| Blazed Wavelength | 250nm | |
| Spectral Bandwidth | 0.1nm, 0.2nm, 0.4nm, 1.2nm automatic change. | |
| Flame Atomizer | Burner | 10cmsingle slot all-titanium burner |
| Spray chamber | Corrosion resistant all-plastic spray chamber. | |
| Nebulizer |
High efficiency glass nebulizer with metal sleeve, sucking up rate: 6-7mL/min |
|
| Emission burner | Provided with WFX-110B/120B | |
| Detection and Data Processing System | Detector | R928 Photomultiplier with high sensitivity and wide spectral range. |
| Software | Windowsoperating system | |
| Analytical method | Working curve auto-fitting; standard addition method; automatic sensitivity correction; automatic calculation of concentration and ontent. | |
| Repeat times | Maximum 20 times of repeat measurement, automatic calculation of mean value, standard deviation and relative standard deviation. | |
| Multi-task function | Sequential measurement of multi-elements in one sample | |
| Condition reading | With model function | |
| Result printing | Measurement data and final analytical report printout, editing with Excel. | |
| Standard RS-232 serial port communication | ||
|
Characteristic Concentration and Detection Limit |
Normal Air-C2H2 flame |
Cu: Characteristic concentration≤ 0.025mg/L, Detection limit≤ 0.006mg/L; |
| Oxygen-rich Air-C2H2 flame |
Ba: Characteristic concentration ≤ 0.22mg/L Al: Characteristic concentration ≤ 0.4mg/L (for WFX-110B) |
|
| Function Expansion | Hydride vapor generator can be connected for hydride analysis. | |
| Dimensions and weight | 1020 (L) × 490(W) × 540 (H) mm (main unit), unpacked 80kg | |