LXLCR Removable Woltman Water Meter(dry type)
Set of moving device that fitted into a closed conduit driven directly by water flow. Its turbine rotor
rotates about the axis which is perpendicular to water flow.
Application:--Measuring the volume of cold (hot) water passing through the pipeline
Features:-Selected sensitive read-type pluses;
-Resistance to interference;
-Keep its fundamental function;
-Consumption can be collected by remote transit with accurate and reliable reading;
-Can be connected with compter , for management;
-All technical figures are conformed with GB/T778.1~3-1996 which is equivalent to ISO4064 Standard Class B.
Working condition: Water temperature: 0.1ºC~40ºC ( 0.1ºC~90ºC for hot water meter)
Water pressure: ≤1Mpa (1.6MPa for special requirement)
Technical parameters:Type | Size (mm) | Class | qs Overload Flow | qp Permanent Flow | qt Transitional Flow | qmin Min. Flow | Min. Reading | Max. Reading |
m3/h | m3 |
LXLCR-50 | 50 | A | 30 | 15 | 4.5 | 1.2 | 0.0002 | 999,999 |
B | 3.0 | 0.45 |
LXLCR-65 | 65 | A | 50 | 25 | 7.5 | 2.0 | 0.0002 | 999,999 |
B | 5 | 0.75 |
LXLCR-80 | 80 | A | 80 | 40 | 12 | 3.2 | 0.002 | 999,999 |
B | 8.0 | 1.2 |
LXLCR-100 | 100 | A | 120 | 60 | 18 | 4.8 | 0.002 | 999,999 |
B | 12 | 1.8 |
LXLCR-125 | 125 | A | 200 | 100 | 30 | 8 | 0.002 | 999,999 |
B | 20 | 3 |
LXLCR-150 | 150 | A | 300 | 150 | 45 | 12 | 0.002 | 999,999 |
B | 30 | 4.5 |
LXLCR-200 | 200 | A | 500 | 250 | 75 | 20 | 0.002 | 999,999 |
B | 50 | 7.5 |
LXLCR-250 | 250 | A | 800 | 400 | 120 | 32 | 0.002 | 9,999,999 |
B | 80 | 12 |
LXLCR-300 | 300 | A | 1200 | 600 | 180 | 48 | 0.02 | 9,999,999 |
B | 120 | 18 |