Categories
Price: | Negotiable/Piece |
---|---|
Trade Terms: | FOB |
Min Order: | 1/Piece |
Pay Type: | T/T |
Prod Model: | BY-12-4 |
---|---|
Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
Lights: | LED |
Type: | Electrostatic Spraying Equipment |
Certification: | SGS |
Method Type: | Automatic |
Application: | Car Spraying |
Insidedimension | 15000× 5000× 5000 mm (L× W× H) |
Outsidedimension | 15144× 6896× 5600 mm ( L× W× H ) |
Pits | 2 rows of pits in the ground for outlet, dimension of each pit is 13850× 760mm (L× W), with galvanized grilles made by twisted steel and flat bar above. |
Front door | Folding door, 4-folds, 4000× 4500mm (W× H), galvanized steel frame, with polystyrene (EPS) inside, colour: white. |
Emergency door | 2 units, 800× 2000 mm (WXH), colour: white. |
Room body | Profiled bar beams in the roof to strengthen the room body; wall panel thickness: 70mm, width: 1150mm, tongue and groove structure, 0.476mm colour steel with polystyrene(EPS) insulation inside, colour: white. |
Light system | Ceiling Lights: 18Units× 4Pcs=72Pcs× 36W, Side Lights: 22Units× 4Pcs=88Pcs× 36W, up and down interleaving installation, with electronic ballasts. |
Generator cabinet | Intake from side upper, exhaust from back upper, quadrate steel frame, outside is white coated steel, inside is galvanized steel, filled with heat preservation material inside. |
Intake and exhaust system(2 sets) | Inlet: 2 sets, in total 4× 7.5KW double-intake centrifugal fans, model YDW4.5M, air capacity is 21000m3/h for each fan; |
Outlet: 2× 11KW double-intake centrifugal fans, with motor outside, belt-drive, model TAE-710H, air capacity is 36000m3/h for each fan. Equip manual dampers for exhaust. | |
Heating system(2 sets) | 2 units RIELLO RG5S diesel burners, heating productivity: 520000 Kcal/h, stainless steel heat exchanger, pneumatic dampers actuate from spraying to baking cycle. |
Purification system | Pre-filter, high efficiency filter(ceiling filter), exhaust fiberglass fiter, activated carbon filter. |
Roof | 50mm thick EPS heat preservation panels. |
Control system | Spraying, heat spraying, baking, time setting, lighting switch, failure indicator, thermostat, power supply switch, emergency stop, ampere meter, voltmeter, hours meter, temperature limit controller, pressure gauge. Exhaust star-delta motor start. |
Total power | 60KW |