Categories
Price: | US $ 14.75/Piece |
---|---|
Trade Terms: | FOB,CFR,CIF |
Min Order: | 1/Piece |
Pay Type: | L/C,T/T,Money Gram,Western Union |
1.Application
For electric coontrol system of communication power supply, engineering machine, electromotion forklift, motor car, train, watercraft and UPS etc
2.Basic technical data
W-100/125/150-S series DC contactors are suitable for the battery or the rectification power and supplies power,using for handling drawing, the pump motor and other electronic vehicles.
Parameters | Coil voltage of contact circuit (V) |
6 -220V | |
Coil power | 8-12W |
Main rated load current of contact circuit(A) | 100A,125A,150A |
Rated voltage of contact circuit (V) | 6-80V DC |
Dielectric(volt)strength | 50Hz 1000V AC 1min |
Current volt drop of main contact at 100A | Not above 80mV |
Operating time | Pickup(contact makes): 30ms, release (contact breaks): 30ms |
Action characteristic | Pickup(contact makes):66%Us, Release(contact breaks):30%Us,5%Us |
Mechanical life | 100 thousand times |
Electric life | 20 thousand times |
Prod Model: | 125A |
---|---|
Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
-: | - |
Size: | Miniature |
Theory: | Electromagnetic Relay |
Usage: | Car Relay, Household Appliances Relay, Communication Relay, Lathe Relay |
Protective Characteristics: | Sealed relay |
Load: | High Power Relay |
Action Principle: | Electronic Type |