Price: | Negotiable/Piece |
---|---|
Trade Terms: | FOB,CFR,CIF |
Min Order: | 1/Piece |
Pay Type: | L/C,T/T,D/P,Paypal,Money Gram |
Prod Model: | Fluke 1621 |
---|---|
Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
Power: | One 9 Volt Alkaline (Lr61) |
Product Dimension: | 113 X 54 X 216 mm |
Weight: | 850g |
Category: | 600 V Cat II |
Earth Ground Resistance: | 0.15~2.00k Ohm |
Test Voltage: | 3.7kv |
Protection Type: | IP40 |
2 Pole And 3 Pole Mode: | Available |
Measuring Rate: | 2 Measure/Sec |
Intrinsic Error: | Yes |
General Specifications | ||
Measuring functions | 3-pole earth ground resistance, 2-pole ac resistance of a conductor, Interference voltage | |
Intrinsic error | Refers to the reference temperature range and is guaranteed for one year | |
Measuring rate | 2 measurements/second | |
Battery1 | One 9 volt alkaline (LR61) | |
Battery condition | LO-BAT is displayed if voltage drops below 6.5 V | |
Voltages | Between jacks H/C2 and E/C1 | 250 Veff maximum (effective voltage) |
Between jacks S/P2 and E/C1 | 250 Veff maximum | |
Climatic class | VDE/VDI 3540 RZ (conforming to KWG as per DIN 40040, 4/87) | |
Temperature performance2 | Working | -10°C to +50°C (+14°F to +122°F) |
Operating | 0°C to +35°C (+32°F to +95°F) | |
Storage | -20°C to +60°C (+68°F to +140°F) | |
Reference | +23°C ±2°C (+73°F ±4°F) | |
Temperature coefficient | ±0.1% of range per degree Kelvin | |
Safety | IEC/EN 61010-1, c, pollution degree 2 | |
Dimensions | 113 x 54 x 216 mm (4.5 x 2.1 x 8.5 in), including holster | |
Weight | 850 g (1.9 lb), including standard accessories, volume approximately 600 cm3 | |
Electrical Specifications | ||
Maximum deviations | E1Influence factor | Position |
E1Deviation influence | 0% | |
E2Influence factor | Supply voltage | |
E2Deviation influence | 0% | |
E3Influence factor | Temperature E3 | |
E3Deviation influence | 2.3% | |
E4Influence factor | Serial interference voltage (20 V) | |
E4Deviation influence | 0.6% | |
E5Influence factor | Probe- and auxiliary probe resistance | |
E5Deviation influence | 10% | |
Test voltage | 3.7 kV | |
Protection type | IP 40; IEC/EN 60529 | |
Electromagnetic compatibility | Emission | IEC/EN 61326 Class B |
Immunity | IEC/EN 61326 Annex C | |
RE Resistance measurement | Measuring method | Current-voltage measurement with improved cross-talk attenuation, no compensation of measuring lead resistance, with probe (3-pole) or without probe (2-pole), as per IEC/EN 61557-5 |
Open circuit voltage | 23 to 24 V AC | |
Short circuit current | > 50 mA AC | |
Measuring frequency | 128 Hz | |
Maximum permissible overload | 250 Veff | |
Measuring time | 8 seconds (average from when START is pressed) | |
Limit input | Tester retains set value even if instrument is turned off (assuming battery power supply is sufficient) | |
Automatic changeover of resolution | RH | < 7 kΩ |
Resolution | 0.01 Ω | |
RH | < 50 kΩ | |
Resolution | 0.1 Ω | |
RH | > 50 kΩ | |
Resolution | 1 Ω | |
Interference voltage display DC + AC | Vmax | 30 Veff |
Common mode rejection | > 80 dB at 50 Hz and 60 Hz | |
Ri | 680 kΩ | |
Measuring uncertainty | < 10% for pure AC and DC signals | |
Measuring Range | ||
0.15 Ω to 20 Ω | Resolution | 0.01 Ω |
Display range | 0 to 19.99 Ω | |
200 Ω | Resolution | 0.1 Ω |
Display range | 20 to 199.9 Ω | |
2 kΩ | Resolution | 1 Ω |
Display range | 200 to 1999 Ω | |
Intrinsic Uncertainty | ±(6% of measured value + 5D) | |
Operating uncertainty IEC 615573 | ±(18% of measured value + 5D) | |
1. If the tester is not going to be used, or is being stored for a long period, remove the battery and store separately from the tester to avoid damage from battery leakage. 2. The four temperature ranges for the tester exists to satisfy European Standards requirements; the instrument can be used over the full working temperature range by using the temperature coefficient to calculate accuracy at the ambient temperature of use. 3. Covers all deviations caused by influence quantities E1-E5. If the deviation E4 caused by high probe or auxiliary probe resistance is higher than specified flashes. Measured values are outside of the specified operating uncertainty. |