| Supplier: | Zhejiang Cen New Energy Technology Co., Ltd. |
|---|---|
| Price: | Negotiable/Piece |
| Min Order: | 2/Piece |
| Quantity:: | |
| Trade Terms: | FOB,CIF,EXW |
|
|
| Prod Model: | CSGRS-4I |
|---|---|
| Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
| Product Name: | Ground Source Heat Pump for Cooling & Heating and |
| Refrigerant: | R410A |
| Compressor: | SANYO |
| Rated Heating Capacity: | 4.3kw |
| Cooling Capacity: | 4kw |
| Hot Water Heating Capacity: | 4.8kw |
| Heat Source: | Ground-source |
| Certification: | CCC |
| Work Environment: | Common Heat Pump |
| Heat Temperature: | 50-70??C |
| Application: | Villa Family |


Application| Water/Ground Source Heat Pump combines Cooling, Heating and Hot Water Production (heat recovery) | |||||||
| Parameters | CSGRS-4I | CSGRS-8I | CSGRS-12II | CSGRS-20II | CSGRS-40II | ||
| Hereunder is the testing result under standard conditions: (1) standard cooling conditions: application side water inlet temperature 12, water outlet temperature 7; source side water inlet temperature 15, water outlet temperature 20. (2) standard heating conditions: application side water inlet temperature 40, water outlet temperature 45; source side water inlet temperature 15, water outlet temperature 10. | |||||||
| Cooling Capacity | kW | 4 | 8 | 12 | 20 | 40 | |
| Heating Capacity | kW | 4.3 | 8.6 | 13 | 22 | 45 | |
| Hot Water Heating Capacity (entire heat recovery ) | kW | 4.8 | 9.5 | 14.5 | 23.5 | 48.5 | |
| input power for cooling | kW | 0.8 | 1.6 | 2.5 | 4.1 | 8.3 | |
| input power for heating | kW | 0.95 | 1.9 | 2.8 | 4.7 | 10.2 | |
| input current for cooling | A | 4.2 | 8.4 | 4.5 | 7.6 | 15.2 | |
| input current for heating | A | 5.1 | 10.2 | 5.3 | 8.7 | 18.2 | |
| Hereunder is the testing result in underground water norminal conditions: (1) underground water norminal cooling conditions: application side water inlet temperature 12, water outlet temperature 7; source side water inlet temperature 18, water outlet temperature 29. (2) underground water norminal heating conditions: application side water inlet temperature 40, water outlet temperature 45; source side water inlet temperature 15, water outlet temperature 7. | |||||||
| underground water norminal conditions | Cooling Capacity | kW | 3.9 | 7.7 | 11.5 | 19.5 | 38.4 |
| Heating Capacity | kW | 4.2 | 8.2 | 12.5 | 21.2 | 43.2 | |
| Hot Water Heating Capacity (entire heat recovery ) | kW | 4.5 | 9.1 | 13.5 | 23.3 | 47.5 | |
| input power for cooling | kW | 0.81 | 1.6 | 2.6 | 4.1 | 8.2 | |
| input power for heating | kW | 0.93 | 1.8 | 2.7 | 4.8 | 9.8 | |
| input current for cooling | A | 4.4 | 8.5 | 5 | 7.7 | 15.3 | |
| input current for heating | A | 4.8 | 10.2 | 5.1 | 9.1 | 18 | |
| Hereunder is the testing result in ground source closed loop norminal conditions: (1) ground source closed loop norminal cooling conditions: application side water inlet temperature 12, water outlet temperature 7; source side water inlet temperature 25, water outlet temperature 30. (2) ground source closed loop norminal heating conditions: application side water inlet temperature 40, water outlet temperature 45; source side water inlet temperature 10, water outlet temperature 5. | |||||||
| ground source closed loop norminal conditions | Cooling Capacity | kW | 3.8 | 7.6 | 11.4 | 19.1 | 38 |
| Heating Capacity | kW | 4.1 | 8.1 | 12.3 | 20.9 | 42 | |
| Hot Water Heating Capacity (entire heat recovery ) | kW | 4.4 | 8.9 | 13.2 | 22.5 | 46.2 | |
| input power for cooling | kW | 0.8 | 1.6 | 2.5 | 4.2 | 8.4 | |
| input power for heating | kW | 1.1 | 2.1 | 3.1 | 5.1 | 10.5 | |
| input current for cooling | A | 4.2 | 8.4 | 4.7 | 7.9 | 15.6 | |
| input current for heating | A | 5.7 | 11.1 | 5.8 | 9.6 | 19 | |
| Hereunder is the testing result in water loop norminal conditions: (1) water loop norminal cooling conditions: application side water inlet temperature 12, water outlet temperature 7; source side water inlet temperature 30, water outlet temperature 35. (2) water loop norminal heating conditions: application side water inlet temperature 40, water outlet temperature 45; source side water inlet temperature 20, water outlet temperature 15. | |||||||
| water loop conditions | Cooling Capacity | kW | 3.6 | 7.2 | 10.9 | 18.1 | 36.2 |
| Heating Capacity | kW | 4.7 | 10.3 | 15.6 | 26.4 | 54.6 | |
| Hot Water Heating Capacity (entire heat recovery ) | kW | 5.1 | 11.3 | 17.1 | 29.1 | 60 | |
| input power for cooling | kW | 0.97 | 1.9 | 2.9 | 4.9 | 9.5 | |
| input power for heating | kW | 1.05 | 2.3 | 3.5 | 6 | 12.1 | |
| input current for cooling | A | 5.1 | 10.3 | 5.6 | 9.2 | 17.6 | |
| input current for heating | A | 5.5 | 12.3 | 6.7 | 11 | 22.5 | |
| Power Supply | 220V/50Hz | 380V/50Hz | |||||
| Compressor | Type | Rotor Type | Scroll Type | ||||
| quantity | pc | 1 | 1 | 1 | 1 | 2 | |
| energy adjust | % | 0, 100 | 0, 100 | 0, 100 | 0, 100 | 0, 50, 100 | |
| source side heat exchanger | type | plate-type heat exchanger | |||||
| water flow in underground water type cooling condition | m 3 /h | 0.36 | 0.7 | 1.1 | 1.8 | 3.6 | |
| water flow in underground water type heating condition | m 3 /h | 0.42 | 0.83 | 1.3 | 2.1 | 4.2 | |
| water flow in ground closed loop and water loop cooling condition | m 3 /h | 0.7 | 1.4 | 2.2 | 3.6 | 7.2 | |
| water flow in ground closed loop and water loop heating condition | m 3 /h | 0.66 | 1.31 | 1.96 | 3.3 | 6.6 | |
| Water Pressure Drop | kPa | < 30 | < 50 | ||||
| pipe size | mm | DN20 | DN20 | DN20 | DN25 | DN40 | |
| application side heat exchanger | type | plate-type heat exchanger | |||||
| water flow during cooling | m3/h | 0.69 | 1.38 | 2.1 | 3.5 | 6.9 | |
| water flow during heating | m3/h | 0.7 | 1.4 | 2.3 | 3.8 | 7.7 | |
| Water Pressure Drop | kPa | < 30 | < 40 | ||||
| pipe size | mm | DN20 | DN20 | DN20 | DN25 | DN40 | |
| hot water side heat exchanger | type | efficient shell and tube heat exchanger | |||||
| water flow during heating | m3/h | 0.82 | 1.6 | 2.4 | 4 | 8.2 | |
| Water Pressure Drop | kPa | < 30 | < 50 | ||||
| pipe size | mm | DN20 | DN20 | DN20 | DN25 | DN40 | |
| Protection | high pressure and low pressure protection, anti-freezing protection, high temperature protection, safety valve, overload protection, lack phase protection, reverse phase protection, water flow protection ect. | ||||||
| refrigerant | type | R410A | |||||
| Throttle Type | thermostatic expansion valve | ||||||
| quantity | kg | 0.9 | 1.3 | 2.1 | 3.2 | 3.5× 2 | |
| unit dimensions | Length | mm | 900 | 900 | 956 | 956 | 1315 |
| Width | mm | 510 | 510 | 556 | 556 | 765 | |
| Height | mm | 600 | 600 | 680 | 680 | 1045 | |
| Noise | ≤ dB(A) | 35 | 48 | 52 | 54 | 61 | |
| Weight | kg | 52 | 65 | 75 | 125 | 290 | |
| Remarks: | |||||||
| 1, Hot water side initial water temperature 15, outlet water temperature 55. | |||||||
| 2, The product parameters may have some difference from the final product because of products updating, please refer to | |||||||
| final product label when buy. Our company keeps the right to interpret. | |||||||