Product Specifications
| Markets: |
North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
| Sensor: |
Tube/Flange |
| Accuracy: |
?à0.6-1% |
| Measuring Media: |
Liquid |
| Measuring Principle: |
Electrical Principles |
| Main Application: |
Fuel Oil |
| Type: |
Positive Displacement Flow Meter |
| Size: |
Dn10-Dn200 |
Product Description
Product Classification:
LC-A: Cast-iron Oval Gear Flow meter, applied widely in various oil or other medium which is not corrosive to cast iron material;
LC-E: Cast-steel Oval Gear Flow meter, applied in the low-corrosive fluids with high pressure.
LC-Q: Cast-iron Oval Gear Flow meter, the rotors material is aluminum. Applied in the situation when the fluids is low viscosity, low corrosive (such as gasoline)
LC-B, C: Stainless steel Oval Gear Flow meter, applied to strong corrosive fluids such as acid, alkali, salty or organic chemicals.
LC-L: Aluminum oval gear flow meter, it is light type flow meter used to measure low-corrosive fluids (such as water).
General Technical Specification
1. Materials of main parts and the nominal operating pressure
Shell and cover cover plate oval wheel Rotary shaft Sheath of shaft Nominal pressure(MPa)
LC-A Cast steel Cast iron Stainless steel Bronze(with oil) or rolling bearing 1.6
LC-E Cast steel Cast iron\Stainless steel Under DN50 6.3
DN80-100 4.0
DN150-200 2.5
LC-Q Cast iron Cast iron Alloy aluminum, engineering material graphite 1.6
LC-B\C Stainless steel Stainless steel Stainless steel graphite 1.6\2.5
LC-L Cast
Aluminum Cast iron,
Stainless steel Alloy
Aluminum, engineering material Bronze(with oil)\graphite\rolling bearing 1.6
Notes: 1. OCr18Ni12Mo2Ti for type LC-C; OCr18Ni9Ti for type LC-B.
2. Flange is convex under 2.5MPa, and roughness at 6.3 MPa; And both of the above at 4.0 MPa.
2. Accuracy class class 0.5, class 0.2 (normal operating temperature -10° C~+60° C)
3. Measured media temp. (environment temperature -41° C~+50° C)
LC-A\B\C: -20° C~+60° C; 60° C~200° C(with high temp. Radiator installed)
LC-Q\L: -20° C~+60° C;
4. Explosion-proof mark: ExiaIICT5, dIIBT4
Note: If the temperature of the metered liquid is higher than 80° C. The maximum flow fate will be 90% of the primary flow, and the minimum will be 120%.
Silver Automation Instruments are expert in the Manufacturing and sales of industrial process instrumentation. Our products have passed ISO9001 International Quality System.
The main classifications are:
Flow measurement,
Level measurement,
Temperature measurement,
Panel meters & chart recorders;
Our main products are: SDRD & SODA series Radar level sensor, SHD magnetic flow meter, STLU Vortex Flow meter, HH5 Variable area flow meter, SGW Gas Turbine Flowmeter, SLW Liquid Turbine Flowmeter, LC Oval Gear Flowmeter, SH series Pressure transmitters and SX series chart recorders & Temperature instruments. All the products are calibrated before leaving factory.
Our products are widely used in chemical industry, environmental protection, metallurgy, pharmaceutical, paper making, water supply and treatment etc.
The principle of our company is " Managing Our Company Creatively and Satisfying Our Customers".
The advantage of Silver Automation Instruments is
Quite reasonable price, Professional Service & Fast delivery time.
We provide qualified products and excellent services to our customers, and develop together with the friends in automation instruments fields.