Product Specifications
| Prod Model: |
H-2000 |
| Markets: |
North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
| Control Mode: |
Air Temp,Skin Temp |
| Audible & Visual Alarms: |
Power Failure, Sensor Failure, Higher & Lower Temp |
| Instant Parameter Displaying: |
Set Temp, Air Temp ,Skin Temp,Heater Power Rate |
| Operate Port: |
6 (2 Iris Ports) |
| Tubing Grommets: |
4 |
| Airtemp Control Range: |
20°c~37°c |
| Skintemp Control Range: |
30°c~37°c |
| Skin Temp Sensor Accuracy: |
≤0.3°c |
| Noise Level Within Hood Environment: |
≤55db |
| Infant Bed Tilt Adjusting: |
±10° Step-Less |
| Certification: |
ISO13485 |
| Theory: |
Infant Incubator |
| Group: |
Infant |
Product Description
Infant Incubator (H-2000)
STANDARD COMPOSITION:
Servo Control Mode:Air temp, skin temp;
Instant Parameter Displaying:Set temp, air temp ,skin temp, heater power rate;
Audible & Visual Alarms:Power failure, sensor failure, higher & lower temp, air& skin temp override, fan failure, system failure;
>37°C Preset Mode:Power failure reset memory, alarm silence, keypad lock, self-test function;
Hood with dual slope:6 hand-ports;Left & right cabinets, top-shelf;
RS-232 Output Connector (Use for network system )
SPECIFICATION
POWER
Model H-2000-1E:110 / 120 V ac, 50Hz / 60Hz
Model H-2000-2E:220 / 240 V ac, 50Hz / 60Hz
Power Input:≤400VA
Refer to IEC60601-1, this equipment belongs to ClassI, Type BF Its operation is continuous
ALARM
Power Alarm
Power Failure:Activates if primary power to the Incubator fails or the power wire is accidentally disconnected from the wall receptacle
Fan Alarm
Fan Failure:Activates if Fan motor malfunctions
Sensor Alarm
Air Sensor Failure:Air Sensor malfunction, refer unit to service
Sensor Out of Position:Activated when Sensor is not in correct position to perform calibration or continue operation
Skin Sensor Disconnected:Activated during Skin Control Mode when Skin Sensor is disconnected from Temperature Controller
Skin Sensor Failure:Activated when Skin Sensor malfunctions
Deviation Alarm
High Air Temperature:Activated if displayed Air Temperature is 15°C above set point
Low Air Temperature:Activated if displayed Air Temperature is 25°C below set point
High Skin Temperature:Activated if displayed Skin Temperature is 10°C above set point
Low Skin Temperature:Activated if displayed Skin Temperature is 10°C below set point
Over Temperature Alarm
Over Air Temperature:Activated when displayed Air Temperature was approach 38°C for set temperature ≤37°C, or approach 40°C for set temperature >37°C in Air Mode
Over Skin Temperature:Activated when displayed Skin Temperature was approach 38°C for set temperature ≤37°C, or approach 39°C for set temperature >37°C in Skin Mode
System Alarm
System Failure:Activated if Temperature Control System malfunctions
TEMPERATURE CONTROL RANGE AND CORRELATIVE SPECIFICATIONS
Air Temperature:20°C~37°C,for set temperature ≤37°C, 37°C~39°C, for set temperature >37°C
Skin Temperature:20°C~37°C,for set temperature ≤37°C, 37°C~38°C, for set temperature >37°C
Temperature Rise Time :≤30min
Temperature Variability:±05°C
Temperature Uniformity:≤1°C
Skin Sensor Precision:≤03°C
ENVIRONMENT REQUIREMENT
Environment Temperature
Operation Temperature Range:+20°C ~ +30°C
Store Temperature Range:-40°C ~ +55°C
Environment Humidity
Operation Humidity Range:30%~75%
Store Humidity Range:10%~100%
Atmospheric Pressure Range:700hPa~1060hPa
OTHER SPECIFICATION
Noise Level Within Hood Environment:≤55dB(Environment noise below 45dB)
Carbon Dioxide (CO2) Level within the Hood:Less than 05% when a mixture of CO2 in air is delivered at 750ml/min at a point 10cm above the center of the mattress
Air Velocity Over Mattress:Less than 035m/s
Infant Bed Max Load:10kg
Transfusion Shelf Max Load:2kg
Cabinet Max Load:6kg
FUNCTION OF ""SILENCE KEY
Make the alarm to be silence for 10 minutes by press this key, following:
Deviation Alarm
Sensor Alarm
Fan Alarm
FACTORY DEFAULT SETTINGS
Temperature Control Mode Air Temperature Mode
Air Set Temperature:32°C
Skin Set Temperature:34°C
Temperature Units:°C
NOTE:Open Access Panel or Access Door or the use of supplies or other equipment within the Incubator, which can alter the air flow pattern, may effect temperature uniformity, temperature variability, the correlation of the Incubator temperature reading to center mattress temperature and skin temperature
We, Healicom is one of the leading professional suppliers in medical field in China. Our product range widely covers Surgical equipment, X-ray machine, Lab device, Patient Monitor, ECG, Ultrasound Scanner, Dental Equipment, Hospital Furniture, etc.
Established in 2002, as one of Chinese professional medical equipment companies, we specialize in manufacturing and marketing various hospital equipments (apparatus), medical disposable items and household medical appliances.
Our high efficient groups of professional technical and sales staff are able to provide you complete range of service at any time. Being approved by CE, ISO certificate, etc., our products are enjoying popularity in different countries and districts of Europe, America and Middle East, etc. With large exporting volume per year.
Products are manufactured either by ourselves or by cooperating with some reputed companies in China, so our prices are very competitive in international market. Meanwhile, excellent services and on-time delivery help us win great popularity among customers.
Please do not hesitate to contact us if you are interested in any of our products. We are looking forward to establishing business relationships with companies all over the world.
Service advantage
We own a group of very professional technical and sales staff with the high efficiency, who are able to provide you complete range of service at any time.
1) If you have any questions, We can reply it within 1 day, and solve your problems within 3 work days.
2) We are well-informed the local market demand, so I can recommend the suitable product.
3) If the appurtenance we post you has any problem in first one year, we can change it for free ( including shipping cost), and also we can provide the appurtenance for charge within next ten years.
The capacity to support your volume needs
Being approved with CE, ISO, Certificate, etc., With large exporting volume each year. All products are manufactured ourselves or cooperating produced with some reputed companies in China, so our prices are very competitive in international market.
Trade specialists
Our trade team has an average of ten years of experience in dealing with customers from the Europe, America and Middle East, etc. That means you can be sure we'll understand the needs of your market.
Deliver fast
We deliver your orders fast to:
1) Allow a quick reaction to market changes and promptly respond to the customers'demands.
2) Reduce lead time and planning time
3) Within 15-30 days after received your payments for goods, you can receive your products.
Warmly thank you again for your kindly visit of our website!