CX-VAFM-LZ Main technical parameters of LZ series intelligent metal tube rotameter flowmeter
Product Description:
LZ Type Metallic Tube Rotameter, which is based on the variable area type measurement theory, suitable for measuring liquids and gases. It is of the all-metal structure.There are six types of LZ Type Metallic Tube Rotadameter, which include the indication type, the electric remote transmission type, the decay resistance type, high pressure type, the clamp type and the explosion-proof type. It also has a special specification type which is with the magnetic filter.It has the following functions: Standard analog signal output of 0-10 mA and 4-20 mA and spot indication, accumulation, digital communication, modifying the measured parameters on the spot, different methods of power supply.It is widely used to measure the flow of the gases and liquids in the condition of complex sever surroundings in the industry of petroleum, chemical, power-generating, medicine-making, food, water treatment, etc.
workflow:
installation:
Application Condition:
1. Offer OEM service
2.Customized is acceptable
3. Provide quality assurance with one year warranty.
4.24 hours on line
Company Information:
CIXI Flowmeter Co.,Ltd. Was established in 2008 and since then has been dedicating itself to research and manufacture of various kinds of flowmeters and level meters. With sophisticated experience in technology and management, CIXI Flowmeter has made a performance of products. CIXI Flowmeters are being applied in more and more fields where there's liquid to measure. CIXI Flowmeters have found users in many countries besides China, such as Malaysia, India, Thailand, Vietnam, Singapore, Iran, Irak, Saudi Arabia, Tunis, South African, Ghana, Spain, Danmark, Holland, Ireland, America and so on. Increasing number of users are finding that CIXI Flowmeter are kind of product with super performance and reasonable price.
Our goal is to continue to offer the most complete line of flow meters, level sensors and controllers in the flow and level control industry. We will draw on our technical expertise to provide our customers with a cost-effective products for their flow and level control needs. We will,if necessary,design and manufacture a customized product to meet our customers'needs. Our mission is simple –to –do whatever it takes to offer the best value and quality in the flow and level control industry.
We are expecting sincere cooperation.If you have interest,please feel free to contact us at any time.We are looking forward to hearing from you.
Measurement range | water (20 c) | 1-200000l/h |
air(20c ,0.1013Mpa) |
0.03~4000m3/h | |
Ratio of range |
:10:1 for standard type,20:1 for special type |
|
Precision degree |
standard type 1.5 grade, special type 1.0 grade |
|
Special standard |
standard type:DN15-DN50 4.0Mpa |
|
Special standard: standard |
Special standard: standard type:DN15-DN50 4.0Mpa |
|
Special standard: |
standard type:DN15-DN50 4.0Mpa | |
special grade | :DN15-DN50 25MPa | |
pressure grade ( flowmeter with the jacket ) |
1.6MPa ( it should be agreed with the plant for special type before selection and ordering ) |
|
Pressure loss: |
7KPa-70Kpa | |
Media temperature: |
standard type:-40 c~100 c ,PTFE:0 c~120 c |
|
High temperature type: |
100 c ~450 c |
|
Media viscosity: |
DN15:η<5mPa.s(F15.1-F15.3) DN25:η<30mPa.s η<30mPa.s(F15.4-F15.8) DN50-DN150:<η<30mPa.s |
|
Environment temperature: |
long transmission type: |
-40 c~185c (liquiid crystal will not be damaged), |
normal operation temperature of liquid crystal |
-30 c ~80 c | |
Field pointer type: |
-40 c~100 c | |
Connection pattern: |
Standard type:DIN2501standard flange Special type: random standard flanges or screw threads appointed by the customers |
|
Cable interface: |
1/2NPT internal thread for explosion proof type and M20*1.5 internal thread for other types | |
Power supply: Standard type: |
24VD(two wires system 4-20mA(12VDC-32VDC) | |
Alarm type: |
24VDCthree wires system 4-20mA(18VDC-28VDC) | |
Ac type: |
85-265VAC 50Hz |
|
Battery type: |
3.6V,7.5AH lithium battery, can be used continuously for three years | |
Load characteristic: |
two-wire system:RLmax=50*(-12)Ω=600Ω@24V | |
Alarm type: |
maximum load resistance is 200Ω |
|
AC type: |
maximum load resistance is 200Ω | |
Alarm output: |
Upper limit or lower limit instantaneous flow quantity alarm Switching value alarm;Relay output |
|
Liquid crystal display: |
Range of instantaneous flow quantity display value:0-50000(may include decimal) Range of accumulated flow quantity display value:0-99999999(may include decimal),automatic reset Liquid crystal display:Range of instantaneous flow quantity display value:0-50000(may include decimal) Range of accumulated flow quantity display value:0-99999999(may include decimal),automatic reset |
|
Protection level |
Ip65 |
Prod Model: | CX-VAFM-LZ |
---|---|
Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
Precision Degree: | 1.5 Grade |
Standrad Size: | Dn15-Dn50 |
Standard Pressure: | 4.0MPa |
Ratio Of Range: | 10:1 |
Pressure Loss: | 7kpa-70kpa |
Media Temperature(Standrad): | -40c~100c |
Sensor: | Tube/Flange |
Accuracy: | ?à0.6-1% |
Measuring Media: | Liquid |
Measuring Principle: | Mechanics |
Size: | DN50-100 |
Main Application: | Fuel Oil |