Categories
| Supplier: | Wenzhou Tosun Electric Co., Ltd. |
|---|---|
| Price: | US $ 9-12/Piece |
| Min Order: | 100/Piece |
| Quantity:: | |
| Trade Terms: | FOB,CFR,CIF |
|
|
| Prod Model: | TSM8-125 3P |
|---|---|
| Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
| Rated Voltage: | up to AC 690V |
| Structure: | MCCB |
| Breaking Capacity: | Low Voltage Circuit Breakers |
| Poles Number: | 3 |
| Certification: | TUV |
| Operation: | Manual Type |
| Installation: | Fixed |
| Arc-extinguishing Medium: | Air |
| Speed: | Normal Type Circuit Breaker |
| Function: | Overload, Short-Circuit, Undervoltage |
Application1. TSM8 Moulded Case Circuit Breaker is suitable for circuit AC 50/60 Hz, rated voltage up to AC 690V, rated operating current to 1600A.
2. It features normal structure, reliable performance, complete accessories & high breaking capacity, used for power distribution and preotecting the circuit and electrical quipment against overload and short circuit.
3. It complies with IEC60947-2.
| Rated Current of Release(a) | Thermodynamic Release(ambient tem+40ºC) | Operational Current of Magnetic Release(A) | |
| 1.05ln(cold state) | 1.30ln(heat state) | ||
| ln<=63 | >=1 | >=1 | 10ln±20% |
| 63 | >=2 | >=2 | 10ln±20% |
| 250 | >=2 | >=2 | 5-10ln±20% |
| Type | Rated Current(A) | Number of Poles | Rated Insulating Voltage(V) | Ultimate Short Circuit Breaking Capacity (KA) | Rated Short-circuit Service Breaking Capacity lcs (%icu) | Operation performance (endurance) | ||
| AC380V (400) | AC660V (690) | Load | Unload | |||||
| TSM8-125L | 12.5,16,20,25,32, 40,50,63,80,100,125 | 1,2,3,4 | 500 | 25 | - | 50% | 3000 | 7000 |
| TSM8-160 | 16,20,25,32,40,50, 63,80,100,125,160 | 3,4 | 690 | 35 | 8 | 75% | 4000 | 6000 |
| TSM8-160M | 50 | 10 | 75% | |||||
| TSM8-250L | 100,125,160,180, 225,250 | 800 | 35 | 14 | 100% | 2000 | 6000 | |
| TSM8-250M | 65 | 18 | 75% | |||||
| TSM8-250H | 85 | 20 | 75% | |||||
| Type | Rated Current(A) | Number of Poles | Rated Insulating Voltage(V) | Ultimate Short Circuit Breaking Capacity (KA) | Rated Short-circuit Service Breaking Capacity lcs(%icu) | Operation performance (endurance) | ||
| AC380V (400) | AC660V (690) | Load | Unload | |||||
| TSM8-400L | 225,250,315,350, 400 | 3,4 | 800 | 35 | 18 | 100% | 2000 | 6000 |
| TSM8-400M | 65 | 22 | 100% | |||||
| TSM8-400H | 100 | 30 | 75% | |||||
| TSM8-630L | 400,500,630 | 35 | 20 | 100% | 1000 | 4000 | ||
| TSM8-630M25 | 50 | 22 | 100% | |||||
| TSM8-630H | 65 | 25 | 100% | |||||
| TSM8-800L | 630,700,800 | 35 | 20 | 100% | 1000 | 4000 | ||
| TSM8-800M | 50 | 22 | 100% | |||||
| TSM8-800H | 65 | 25 | 100% | |||||
| TSM8-1250L | - | 3 | 50 | 20 | 100% | 1000 | 4000 | |
| TSM8-1600L | - | |||||||
Components
Under-voltage releaseUS: AC50/60 Hz 400V,230A
When the operation voltage is 35%-70% of the rated voltgae, the under-voltage release should make the breaker trip correctly.
When the operation voltage is 85%-110% of the rated voltage, the under-voltage release shouldd make the breaker close.
In case of the operation voltage less than 35% of the rated voltage, the under-voltage should prevent the breaker from closing.
Note: Only the under-voltage release is energized in advance, can the breaker be recramped and turned-on, otherwise the breaker will be damage
Us: AC50/60Hz 230V 400V; DC110V 220V
The shunt release should make the brealer trip reliably when the operation voltage is 70%-110% of the rated control voltage.
Auxiliary Contact / Alarm Contact
Auxiliary contact and alarm contact: Auxiliary contact is as same as Alarm contact,
Technical Parameter
| Rated Heating Current Ith(A) | Rated Operating Current le(A) | Suited Frame Inm(A) | |
| AC 380V | DC 200V | ||
| 3 | 0.3 | 0.15 | 125,160 |
| 3 | 0.4 | 0.15 | 250,400 |
| 3 | 0.4 | 0.15 | 630,800,1250,1600 |