Power Distribution Box, Cable Branch Box
Product Specifications
| Prod Model: |
power distribution cabinet, power distribution |
| Markets: |
North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
| Dfw10-2(II/III) With Sfg/Fln36 Lbs: |
1150mm/L*1100mm/W*1700mm/H |
| Dfw10-12 With Gis: |
1250mm/L*1100mm/W*1650mm/H |
| Type: |
Power |
| Brand: |
Jny |
| Structure: |
Floor Stand |
| Size: |
1set |
| Application Range: |
Compact Secondary Substation |
| Operation Voltage: |
Middle Voltage |
| Shell Protection Grade: |
IP33 |
| Certification: |
Cnas |
Product Description
1 General Introduction
1.1 Feature on Structure
The DFW series cable distribution cabinet (called the product in the following) using the SF6 load switch or vacuum circuit breaker as a control switch(can select this configuration or not )and including the flood-protection & shielded cable terminals which made by silicone rubber that can be touched when the cable is living. The product have a strong short-circuit making capacity and breaking capacity while active-power load or no-load. We also can configurate arrester & earth fault indicator according to customer's requirements. In the product of this series: every connecting line of RMU can configurate load switch or vacuum circuit breaker, every branch circuit can quit or join the operating freely, and the other ring network circuit would't be affected; Fuse can be assembled on the load switch , while the short-circuit occurred in one branch circuit, the fuse will break the fault circuit and heat the tripper of load switch to break the circuit causing the fault circuit be isolated, so that the continuity of un-fault branch circuit will be guaranteed. 1.2 Application
The cable distribution cabinet is widely used in the cable branching of 10kV power system. When the product is combined with the power cable, it can be provided with flexible configuration, convenient installation, high safety and reliability, simple maintenance, and is convenient to feed and distribute power to the users. The products are widely used in secondary substation, industrial park, housing district, business district, airport, railway, and the other distribution network. It's very suitable for renovation project of city railroad power-grid that can save more investment on electric equipment & cables and improve the reliability of distribution also. 1.3 Service Condition
Operation site:outdoorAmbient temp.: -45ºC ~ 55ºCAltitude: ≤3000mNo recurrent violent vibration or perennial corrosion
1.4 Standards used
IEC_62271Common specifications for high-voltage switchgear and controlgear standards.IEC 60502Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1.2 kV) up to 30 kV (Um = 36 kV) .2 Technical Parameters
2.1 Type Meaning
2.2 Main Technical Parameters
2.2.1 Without switching devices
| Rated voltage | 12kV | Circuit resistance | ≤40μΩ |
| Rated current | 630A | Conductor work temperature | ≤95ºC |
| Rated frequency | 50Hz | Protection Degree | IP33 |
| Partial discharge | ≤10pc/13kV | Humidity test | 11kV/100h |
| Rated short-time withstand current | 20kA/2s | Applicable cable type | AC polythene cable |
| Rated peak value withstand current | 50kA | Applicable cable cross-section area | 35~ 400mm2 |
| Power-frequency withstand | 45kV/1min | Applicable ambient temperature | -45ºC~55ºC |
| Lightning impulse withstand voltage | 105kV | Applicable altitude | ≤3000m |
2.2.2 With switching devices
| Rated voltage | 12kV | Circuit resistance | ≤120μΩ |
| Rated current | 630A | Conductor work temperature | ≤95ºC |
| Rated frequency | 50Hz | Protection Degree | IP33 |
| Partial discharge | ≤ 10pc/ 13kV | Rated breaking current of ring closure | 630A |
| Rated short-time withstand current | 20kA/2s | Rated breaking current of short-circuit | 20kA |
| Rated peak value withstand current | 50kA | SF6 gas pressure | ≤0.45bar @20ºC |
| Power-frequency withstand voltage | 42kV(rms)/1min | SF6 leakage rate per year | ≤0.05% |
| Lightning impulse withstand voltage | 75kV | mechanical life of Load-switch | 2000/5000 times |
| Power-frequency withstand voltage to secondary circuit | 2kV/1min | Applicable cable type | AC polythene cable |
| Negative polarity DC withstand voltage | 52kV/ 15min | Applicable cable cross-section area | 35~ 400mm2 |
| Breaking times of rated current | 100 times | Applicable ambient temperature | -45ºC~55ºC |
| Rated breaking current of cable | 10A | Applicable altitude | ≤2500m |


Note:The data and illustrations are not binding. We reserve the right to modify the contents of this document without prior notice following technical and product developments.With regards to purchase orders, the agreed particulars shall prevail. JNY does not accept any responsibility whatever for potential errors or possible lack of information in this document.© Copyright 2014 JNY. All rights reserved.
SHENZHEN GOLDEN ENERGY WIRING CO.,LTD.
Xitian Industrial Park, Guangming District, Shenzhen City, P.R.China
Tel: +86 0755-21385209
Fax: +86 0755-86265801
Mob: +86 13925284622
http://www.szjny.com
China National High-Technology Enterprise, ABB OEM Factory
Over 10 Years History, More Than 8.3 Million USD Registered Capital
System Certification ISO9001: 2008, IS014001: 2004, OHSMS18001
Shenzhen Golden Energy Wiring Co., Ltd (hereinafter referred to as JNY) is an integrated high-tech enterprise which specializes in high/low voltage switchgears, automatic apparatus and with ability to R&D, manufacturing, sales and service.
Through 10 years' development, JNY has experienced talent echelon, standardized industrial workshop, advanced production equipment and sophisticated testing instruments, advanced technology, excellent quality, perfect after sales service system, fully meet the national electric power industry standard and IEC standards. And has taken the lead getting the certification of ISO9001: 2008, IS014001: 2004, OHSMS18001 and 3C national mandatory product witness. As well as the type tests checked by quality test center specified by state and the provincial technical appraisal that can fully meet the power ministry, substation, power plants, airports, petrochemical, metro and other large electric power construction projects and the end user's requirements.
Main products
(40.5 kV, 24kV, 12kV, 0.4kV power transmission and distribution products)
Box-type substaion, Switchgear, RMU, GIS,
Circuit breaker, Load-break switch, disconnector
Safe 40.5kV GIS, XGN15-24 SF6 ring main unit, KYN28-12(GZSI) withdrawable metal-clad switchgear, HXGN-safe/SF6 full-insulated & full-sealed integrated RMU, SF6 load-switch, JVS1 vacuum circuit breaker, load breaker switch, disconnector, YB box-type transformer substation, Cable distribution cabinet, Low-voltage switchgear equipments etc.
Solution
High-rise Buildings
Electrical Automation
Petrochemical Plant
Iron&Steel Making
Power plant /Grid /
High Way & Tunnel &
Other Products From This Manufacturer