Product Specifications
| Prod Model: |
HT15K |
| Markets: |
North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
| Phase: |
Three Phase |
| Type: |
On-line |
| Protection: |
Short Circuit |
| Brand: |
Etone |
Product Description
UPS Main Features:
1. Online double conversion.
2. Fully DSP control.
3. Advanced PFC technology, high input power facto.
4. High reliability and performance.
5. Wide input voltage range.
6. DC cold start function.
7. Advanced battery charging management.
8. Intelligent fan speed control.
9. ECO and EPO function.
10. Full protection function.
11. Intelligent RS232 /RS485 Communication Port.
12. SNMP adapter or Dry contacts (optional).
13. Advanced no-master-slave parallel technology (optional).
14. Intelligent battery monitor system - MMBM (optional).
Model
HT6K
HT10K
HT15K
HT20K
HT30K
HT40K
Capacity(VA/W)
6K/4.8K
10K/8K
15K/12K
20K/16K
30K/24K
40K/32K
Battery volt
384V
Efficiency
≥ 95%
Nosie
48-54dB(1m away)
53-60dB(1m away)
Dimension
(W× D× Hmm)
550× 720× 1200
Weight (Kg)
240
262
280
332
380
430
Input
AC
3P4W, 380V± 20%
Frequency
50HZ/60HZ± 10%(auto distinguish)
Efficiency
≥ 95%
Output
Voltage
3P4W, 380V± 1%
Frequency
50HZ/60HZ± 0.05%(Battery mode)
Harmonic Distortion
Linear load< 3%, nonlinearity< 5%
Unbalance voltage
Balance load≤ 1%, Unbalance load≤ 3%
Phase shift angle
Balance load≤ ± 1, Unbalance load≤ ± 2°
Trends transient scope
Output: 0~50%~100%≤ 5%, Recovery time≤ 10ms
Overload capacity
110%≥ 300 Min, 125%≥ 10 Min, 150%≥ 1 Min
Peak value factor
3: 1
Waveform
Pure sine wave
Transfer time
0ms
Battery
Type
Sealed Lead acid battery/ Gel battery
Management
Battery smart management system
Max charge current
0.2A× C10
Charge time (typical)
12 hours
System performance
Protect function
Input overvoltage, undervoltage, overload, short circuit, inverter over temperature, battery undervoltage and overvoltage
MTBF
300, 000 h
Temperature
TEM 0~40. Humidity 0-95%(No condension)
Altitude
< 1000m Per 1% decreased for 100m up the altitude is within 4000m)
Communication port
RS232
Remote signal
Dry contact(Battery low voltage, battery refresh, bypass/ failure), EPO port
Remote control
EPO emergency transfer device, bypass
Apply standard
Safe EN50091-1EMC EN50091-2 A class
Protection standard
IP20(The front door open)
Parallel redundancy
N+1, N+X, Support different capacity parallel
Interface
Windows9x, 2000, NT, Me, XP, Linux, Novell, Macosx, NT4.0
Others
Dustproof, waterproof, Isolation transformer, lighting surge absorb, static switch, manual maintance switch