Basic parameters |
Dimensions(mm) | 120.0(113.0)*52.00*28.00mm | CoilData | Note | ||||||
|
ContactArrangement |
3A,3B |
CoilRated Voltage |
CoilPower |
Goldensectionruleprofile; little distortion; Goodchoicefor Miniaturethree-phaseenergy meters; Higdielectric strength(Min:4000v) |
||||||
|
ContactMaterial |
SilverAlloy |
6-48VDC |
(S):3W (D):6W |
|||||||
| MaxSwitchingCurrent(Anti-Load) |
100A |
SetVoltage |
Reset Voltage |
|||||||
|
MaxSwitchingVoltage |
110VDC/250VAC |
≤80%Rated Voltage |
≤80% Rated Voltage |
|||||||
|
MaxSwitchingPower |
3000W/25000VA |
|||||||||
|
SPECIFIC ATIONS DATA |
Voltage PulseWidth |
Set/ResetTime |
Contact BounceTime |
Contact Resistance |
Insulation Resistance |
DielectricStrengthVr.m.s |
||||
|
≥50ms |
≤30/30ms |
≤5ms |
≤2M Ohm |
≥1000M Ohm |
Betweenopen contacts |
Between Coil&Contacts |
Between Contacts Assembly |
|||
|
LimitAmbientTemp.(Degree) |
ServiceLifeExpectancy |
|||||||||
|
-40 ~ +70 Degree |
Electrical(Operation) |
Mechanical( Operation) |
≥2000VAC |
≥3000VAC |
≥4000VAC |
|||||
| 5x103 | 1x105 | |||||||||
|
Applications |
Three-Phases ElectricalMeters | |||||||||
| AutomaticMeterReading(AMR) | ||||||||||
| AutomaticControldevices | ||||||||||
Manufacturers Directory | Hot Products | China Products | Companies List| Resources Directory | News | Sitemap | Disclaimer | About Us | Contact Us | Cautop|