Product Specifications
| Markets: |
North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
| Arc: |
Furnace Transformer |
| Steel: |
Furnace |
| Type: |
Calcium Carbide Furnace Transformer |
| Reference Standard: |
IEC 60076 |
| No Load Losses: |
52kw |
| Load Losses At 75: |
280 Kw ( 60mva 950V ) (Including LV Lead Losses) |
| Cooling System: |
Ofwf, Double Tube, 2 Coolers in Service |
| On-Load Tap Changer: |
Mr |
| Testing: |
Routine Test According to IEC Standard |
| Phase: |
Three |
| Coil: |
Core-type Transformer |
| Cooling Method: |
Oil-immersed Type Transformer |
| Winding Type: |
Multi-winding Transformer |
| Application: |
Audio |
Product Description
Main function and characteristic
Electric furnace transformers are transformers which supply power to the electric furnaces. It can drop high voltage to the working voltage the electric furnaces need.
There are many kinds of electric furnaces,so there are many kinds of electric furnace transformers cooperating with them.Now,our company manufactures following electric furnace transformers:electric furnace transformers used in steelelectric furnaces(including on-laod,no-load and enclosed reactor) ; mineral hot furnace transformers used to smelt kinds of iron alloys,hydrosilicons,carbides,etc(single phase,three phases on-load and no-load tap changer).They are low loss and energy-saving products.Cooling methods are self-cooling, forced oil water cooling, etc.It can be designed specially according with customers' requirements.
The model of the electric furnace transformer is expressed as follows:
The meaning of model:
H--Steelmaking arc furnace,HJ--ladle furnace,HZ--electro-slag furnace,HC--calcium carbide furnace,HK--mineral hot furnace,HG--line frequency induction furnace;
Number of phase:D--single phase,S--three phase;
Types of cooling device :ONAN,wind cooling F,water cooling S.
The methods of oil circulation:natural circulation,forced oilcirculation P.
Tap changer:off-circuit tap changer,OLTC Z.
Enclosed attached device:changing leakage flux,enclosed reactor K.
Rated capacity:KVA. max 140MVA
Voltage class:KV. 35KV

| 1.1.2 TRANSFORMER DATA |
| General data |
|
| Operating Voltage | 33KV±3% |
| Frequency | 50Hz±1% |
| Rated capacity | 60 MVA |
| Over load power | 60 MVA plus 20%,30 min. |
| Rated primary current | 1049.7 A |
| Insulation Level (AC/LI) | 85/200 kV |
| Vector group | D/d0 with booster regulation transformer inside. |
| Secondary connection | Delta OPEN |
| System short circuit capacity at 33kV side. | 1100 MVA |
| Secondary outlet | Terminals with Bus bars come out from top cover. 8 Buss bars by epoxy resin arranged along with each phase with matching cite transformer sizes. |
| Max. Secondary current | Approximate 42120 A |
| Secondary voltage range | 950-500 V. |
| a) Constant power | 950V-822.4 V at 60 MVA |
| b) Constant current | About 42062 A within 824V-500V |
| c) Short-circuit voltage | 8 % (at 950V,60MVA) |
| Type of tap changer | On load tap-changer: |
| a) Manufacturer | MR, |
| b) Number of tapes | 17 voltage steps with 18position See attached data sheet of 60 MVA EAF transformer. |
| c) Oil filter equipment for OLTC | yes |
| Cooling | OFWF |
Suzhou Silverstone Electric Specialises in Power Transmission, Distribution, Electrical Automation Solutions, Power Quality Solutions, Hydro Power, Solar Power, Power Generation and Substation EPC Consultant.
We manufactures and trades
Power Transformer
--Dry type Transformer (up to 35kV)
--Oil Immersed Transformer (up to 230kV)
GIS (Gas Isolated Switchgear)
--Up to 145kV Compact Gas Insulated Switchgear (GIS)
--Up to 230kV Gas Insulated Switchgear (GIS)
MV Switchgear
--Metal clad AC Enclosed Switchgear
--Packaged Type AC Metal Enclosed Switchgear
--Gas Insulated Switchgear
LV Switchgear
--LV Withdrawable Switchgear
--LV Fixed Switchgear
MV Circuit Breaker
--Vacuum Circuit Breaker
--SF6 Circuit Breaker
--MV Earthing Switch
--Load Break Switch
Reactor
--Dry-type Air Core Reactor Series
--Dry-type Core Series Shunt Reactor
--HV Oil-immersed Shunt Reactor
HV&LV Busbar Trunking System
--Busbar Trunking System (Busway)
--Common Enclosure Busbar
HV Circuit Breaker & Disconnector
--HV Circuit Breaker
--SF6 Circuit Breaker
--HV Disconnector
--Outdoor AC discontector
--HV Earthing Switch
--Outdoor AC Earthing Switch
Capacitor
--All film high voltage shunt capacitor
--High-voltage shunt capacitor banks
--Atlernating filter capacitor complete equipments
Power Protection & Automation
Reactive Compensation
High Voltage Frequency Reactor
Medium voltage variable frequency drives
Medium voltage soft starter
STATCOM (Static synchronous compensator)
Static var compensator with Magnetically controlled reactor
TSC (Thyristor switched capacitor banks)
Active power filter