| Supplier: | Promise Technology Co., Ltd. |
|---|---|
| Price: | Negotiable/Piece |
| Min Order: | 1/Piece |
| Quantity:: | |
| Trade Terms: | FOB,CPT |
|
|
| Prod Model: | VM12B |
|---|---|
| Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
| Size: | 306*287*172mm |
| Display: | 8.4' Color TFT Display |
| Standard Parameters: | ECG/Resp, SpO2, NIBP, Temp, Pulse Rate |
| Battery: | 2200 mAh: 14.8 V Rechargeable Battery |
| Power Supply: | AC :100V - 240V, 50Hz- 60Hz |
| Arrhythmia Analysis: | St Calculation, Pace Analysis |
| Use: | for Medicine |
| Net Weight: | 3.4kg |
| Carton Size: | 430*290*370 mm |
| ECG Lead Mode: | 3/5 Leads |
| Type: | Diagnosis & Injection |
Technical Specification | ECG | Lead Mode: 3/5 leads | ||||
| Lead Method: I. II.III. AVR.AVL.AVF.V; I.II.III | ||||||
| Gain: 2.5/ 5.0/ 10/ 20 mm/mV. | ||||||
| Sweep speed: 12.5/ 25/ 50 mm/s; | ||||||
Heart Rate | Measure range: Adult: 15-300bpm Neonatal/ Pediatric :15-350bpm | |||||
| Accuracy : ±1% | ||||||
| Resolution: 1bpm | ||||||
Respiration | Method: Impedance between RA-LL | |||||
| Gain: ×0.25/ 0.50/ 1/ 2/ 4 | ||||||
Respiration Rate: | Measurement Range: Adult: 0-120BrPM; Neonatal/ Pediatric: 0- 150BrPM | |||||
| Resolution: 1BrPM | ||||||
| Accuracy: 0 - 6 BrPM (unspecified) ; 7-150 BrPM ; ±2BrPM | ||||||
NIBP | Measurement method : Oscillometry | |||||
| Measure Mode: Manual, Auto, STAT, Measure interval | ||||||
| Auto mode: 1,2,3,4,,4,10,15,30, 60,90,120,180,240,480 min | ||||||
| Pulse rate range : 40-240bpm | ||||||
Measure and Alarm Range | Adult Mode | SYS 40-280mmHg | ||||
| DIA10- 220mm Hg | ||||||
| MEAN20-240mmHg | ||||||
Pediatric Mode | SYS 40-220mm Hg | |||||
| DIA10- 160mm Hg | ||||||
| MEAN20-170mmHg | ||||||
Neonatal Mode | SYS 40-135mm Hg | |||||
| DIA10- 100mm Hg | ||||||
| MEAN20-110mmHg | ||||||
| Resolution :1mm Hg | ||||||
| Accuracy: Maximum mean error : ±5mm Hg | ||||||
| Maximum standard deviation: 8mm Hg | ||||||
| Overpressure Protection | Adult :300 mmHg | |||||
| Pediatric :240 mmHg | ||||||
| Neonatal : 150 mmHg | ||||||
SP02 | Measurement range: 0-100% | |||||
| Resolution : 1% | ||||||
| Accuracy: 70% -100%; ±2% <69% : unspecified | ||||||
Pulse Rate | Measure and alarm Range: 20-250bpm | |||||
| Resolution: 1bpm | ||||||
| Accuracy: ±3bm | ||||||
Temperature | Channel: 2 | |||||
| Measure and alarm Range : 0-50 Celsius | ||||||
| Resolution: 0.1 Celsius | ||||||
| Accuracy (no sensor) :±Celsius(0 - 50 Celsius) | ||||||
| Recorder (Option) | Paper Width: 48mm | |||||
| Speed : 25/ 50 mm/s | ||||||
| Wave channels : 3 channels | ||||||
IBP(Option) | Sensor | Reusable sensors : OHMEDA P23XL or BD, EDWARD compatible | ||||
| Single usage : OHMEDA DT-4812 or BD, EDWARD compatible | ||||||
| Excitation Voltage : +5V DC ±2% | ||||||
| Sensitivity: 5uV/V/mmHg | ||||||
| Channels : 2 channels | ||||||
| Measurement range : -50- 360 (mmHg) | ||||||
| Resolution: 1mmHg | ||||||
| Accuracy : (no sensor) : ±2% or ±1mmHg, use the greater | ||||||
| Band Width : Normal Mode: DC 40Hz Smooth Mode: DC 12.5Hz | ||||||
ETCO2 (Option) | Measurement range: 0%-13% | |||||
| Resolution: 1 mmHg | ||||||
| Accuracy: 2mm Hg <5.0% CO2 (at ATPS) | ||||||
| Respiration rate : 3- 150 bpm | ||||||
CSI (Option) | EEG sensitivity : ±475uV | |||||
| CMRR:>100dB | ||||||
| Input Impedance: >50Mohm | ||||||
| Ioc : 0-100 | ||||||
| ESR: 0-100% | ||||||
| EMG: 0-100 | ||||||
| Battery | Dual Detachable Battery; 2200 mAh: 14.8 V rechargeable battery; Operating time: more than 2H working capacity; Max charging time: less than 6H; | |||||
| Power Supply | AC :100V - 240V, 50Hz- 60Hz | |||||
Packing information | Size: 306*287*172mm Net weight: 3.4KG Gross weight: 5.2 KG Carton size: 430*290*370 mm | |||||