Application
A. Application of the conditions of groundwater source heat pump system
1. Rich water near the building, facilitate the implementatiom of the supply and return water
2. Local policy allows using groundwater
3. Groundwater temperature appropriate, the water is suitable, water supply stability, water return smoothly
B. Application of the conditions of the surface water source heat pump system
1. Rich water near the building ( such as river, lake water, seawater, reservoir water, industrialwastewater and so on)
2. Adequate water, moderate temperature, the water can meet the using requirements after simple handling.
C. Pplication of the conditions of ground source heat heat pump system
1. Lake of water near the building or various factors limit use of water resource
2. There is enough space around the building for the ground-couple system.
Advantages
1. High Reliability
Using famous parts, and as the temperature of the original source is stable, the water/ground source heat pump works more reliable and stable, guaranteeing the high efficiency and economy. Without problem of defrosting in winter.
2. One Unit for Multi-usage and Wide Application
It could be used for cooling, heating and tap hot water for daily life, one unit for multi-usage.
3. High Efficiency for Heat Recovery
Using the latest high technology, following the law of conservation, when the unit is cooling, the heat recovers to produce the hot water (for example, in summer, it provides the free hot water by heat recovery). The unit is with higher efficiency and more energy saving.
4. Less Cost
The working condition is reliable, so the system is simple and less components. It runs easily and reliably, and maintenance cost is less.
5. Environment Friendly
Use R410A refrigerant, the ratio of ozonosphere damage is zero, environment friendly, green product, meet the countries' environmental protection demand.
water(ground) source heat pump cooling & heating |
|
Modle | CRS-4I | CRS-8I | CRS-12II | CRS-20II | CRS-40II | CRS-70II | CRS-80II | CRS-120II | CRS-165II | CRS-200II | CRS-240II | CRS-300II |
Cooling capacity | kW | 4 | 8 | 12 | 20 | 40 | 60 | 80 | 120 | 165 | 200 | 240 | 300 |
Heating capacity | kW | 4.3 | 8.6 | 13 | 22 | 45 | 69 | 91 | 131 | 176 | 213 | 260 | 315 |
Cooling input power | kW | 0.8 | 1.6 | 2.5 | 4.1 | 8.3 | 12.7 | 16.6 | 25.3 | 32.3 | 39.2 | 47 | 58.8 |
heating input power | kW | 0.95 | 1.9 | 2.8 | 4.7 | 10.4 | 14.6 | 20.6 | 27.2 | 39.1 | 47.3 | 57.7 | 70 |
Cooling input current | A | 4.3 | 8.4 | 4.5 | 7.5 | 15 | 22.7 | 29.5 | 45.5 | 58 | 71 | 85 | 106 |
Heating input current | A | 5.1 | 10.1 | 5.2 | 8.5 | 18.6 | 27 | 37 | 50.3 | 71 | 86 | 106 | 127 |
Underground working condution | Cooling capacity | kW | 3.9 | 7.7 | 11.5 | 19.5 | 38.4 | 57.6 | 76.9 | 115.3 | 158.6 | 192.3 | 230.7 | 288.4 |
Heating capacity | kW | 4.2 | 8.2 | 12.5 | 21.2 | 43.2 | 66.3 | 85.1 | 125.9 | 169.2 | 204.8 | 250 | 302.8 |
Cooling input power | kW | 0.81 | 1.6 | 2.4 | 4.1 | 8.2 | 12.4 | 16.7 | 24.9 | 32.3 | 39.2 | 47 | 58 |
Heating input power | kW | 0.93 | 1.8 | 2.7 | 4.8 | 10 | 15.4 | 20.3 | 29.2 | 41.2 | 49.9 | 60.9 | 73.8 |
Cooling input current | A | 4.2 | 8.5 | 4.5 | 7.5 | 15 | 23.5 | 31.5 | 46 | 60.2 | 72.9 | 86 | 105 |
Heating input current | A | 4.8 | 9.8 | 5.3 | 9.1 | 18 | 29.1 | 37.5 | 55.3 | 76.6 | 92.8 | 113.2 | 137 |
Underground circle type nominal working condition | Cooling capacity | kW | 3.8 | 7.6 | 11.4 | 19.1 | 38 | 57 | 76.2 | 114.1 | 157 | 190.3 | 228.4 | 285.5 |
Heating capacity | kW | 4.1 | 8.1 | 12.3 | 20.9 | 42 | 65 | 80.1 | 124.6 | 167.5 | 202.3 | 247.5 | 299.8 |
Cooling input power | kW | 0.8 | 1.6 | 2.4 | 4.2 | 8.4 | 12.7 | 16.9 | 25.3 | 32.9 | 39.8 | 47.8 | 59.8 |
Heating input power | kW | 1.1 | 2.1 | 3.1 | 5.1 | 10.5 | 16.2 | 20 | 31.1 | 41.8 | 50.5 | 61.8 | 74 |
Cooling input current | A | 4.2 | 8.4 | 4.7 | 7.9 | 15.6 | 23.6 | 31.9 | 47 | 61.1 | 74 | 88 | 111 |
Heating input current | A | 5.7 | 11.1 | 5.8 | 9.6 | 18 | 30.1 | 37.8 | 57.8 | 77.7 | 93 | 114 | 139.3 |
Circle water working conditon | Cooling capacity | kW | 3.6 | 7.2 | 10.9 | 18.1 | 36.2 | 54.3 | 72.4 | 108.7 | 149.5 | 181.3 | 217.5 | 271.9 |
Heating capacity | kW | 4.7 | 10.3 | 15.6 | 26.4 | 54.6 | 84.5 | 104 | 161.9 | 218 | 266 | 330 | 390 |
Cooling input power | kW | 0.95 | 1.9 | 2.9 | 4.8 | 9.5 | 14.2 | 19.1 | 28.6 | 36.4 | 44.2 | 53 | 66.3 |
Heating input power | kW | 1.04 | 2.3 | 3.4 | 6 | 12.1 | 18.7 | 23.1 | 35.9 | 43.6 | 53.2 | 66 | 78 |
Cooling input current | A | 5.1 | 10.3 | 5.6 | 9.3 | 17.6 | 26.4 | 36 | 53.1 | 67.7 | 82 | 98 | 123.3 |
Heating input current | A | 5.5 | 12.3 | 6.7 | 11.4 | 22.5 | 34.7 | 43 | 66.7 | 81 | 98 | 122.7 | 145 |
power | 220V/50Hz | 380V/50Hz |
Compressor | type | Rotor | Scroll | Double-Screw-Refrigeration Compressors |
NO. | UNIT | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 1 | 1 | 1 | 1 |
Energy regulation | % | 0, 100 | 0, 100 | 0, 100 | 0, 100 | 0, 100 | 0, 50, 100 | 0, 50, 100 | 0, 50, 100 | 0, 25, 50, 75, 100 |
Heating source side heat exchanger | Type | Plate type heat exchanger |
| Horizontal type shell& tube heat exchanger |
|
Underground water make cooling water flow | m 3 /h | 0.36 | 0.7 | 1 | 1.7 | 3.4 | 5.2 | 6.7 | 10.8 | 14.2 | 16 | 20 | 24 |
Underground water make heating water flow | m 3 /h | 0.42 | 0.83 | 1.3 | 2.1 | 4.2 | 6.2 | 8.3 | 12.4 | 17 | 21 | 25 | 31 |
Underground circle type nominal working condition cooling water flow | m 3 /h | 0.7 | 1.4 | 2.2 | 3.6 | 7.2 | 11.2 | 13.7 | 21.4 | 28.8 | 35 | 42 | 52 |
Underground circle type nominal working condition heating water flow | m 3 /h | 0.65 | 1.3 | 1.96 | 3.3 | 6.5 | 9.8 | 13.1 | 19.6 | 27 | 33 | 39.5 | 49 |
Water tube interface | mm | DN20 | DN20 | DN20 | DN25 | DN40 | DN50 | DN80 | DN100 |
User side heat exchanger | Type | Plate type heat exchanger | Horizontal type shell& tube heat exchanger |
|
cooling water flow | m3/h | 0.7 | 1.4 | 2.1 | 3.4 | 6.8 | 10.3 | 13.7 | 20 | 28.3 | 34.4 | 41.3 | 52 |
Heating water flow | m3/h | 0.74 | 1.5 | 2.2 | 3.8 | 7.7 | 11.8 | 15.6 | 22.5 | 30 | 36.6 | 44.7 | 54.2 |
Water tube interface | mm | DN20 | DN20 | DN20 | DN25 | DN40 | DN50 | DN80 | DN100 |
Protector | 1\High and low pressure protection, 2\anti-freeze protection, 3\temperature protection, 4\safety valve, 5\overload protection, 6\Reverse phase, 7\Lack of phase, 8\Separation of water and electricity, ect. |
Refrigerant | Type | R410a/R407c |
Throttle Mode | thermostatic expansion valve |
weight | kg | 0.8 | 1.2 | 1.9 | 3 | 12 | 19 | 23 | 39 | 45 | 56 | 67 | 82 |
Size | Long | mm | 709 | 709 | 709 | 810 | 1760 | 2400 | 2400 | 2560 | 2560 | 2650 | 2890 | 2890 |
Wide | mm | 359 | 359 | 359 | 420 | 500 | 650 | 650 | 880 | 900 | 900 | 900 | 1100 |
High | mm | 592 | 592 | 592 | 590 | 1150 | 1210 | 1260 | 1300 | 1335 | 1430 | 1430 | 1530 |
Noise | ≤ dB(A) | 35 | 35 | 38 | 42 | 55 | 60 | 60 | 62 | 65 | 66 | 66 | 68 |
Weight | kg | 43.8 | 45 | 69 | 93 | 340 | 570 | 612 | 850 | 1150 | 1300 | 1450 | 1850 |
Note: 1, Underground circle type nominal cooling working condition: User side water inlet/outlet temperature 12º C/7º C; Source side water inlet/outlet temperature 25º C/30º C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Underground circle type nominal Heating working condition: User side water inlet/outlet temperature 40º C/45º C; Source side water inlet/outlet temperature 10º C/5º C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2, Underground water type nominal cooling workingcondition: user side water inlet/outlet temperature 12º C/7º C; source side water inlet/outlet temperature 18º C/29º C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Underground water type nominal heating workingcondition: user side water inlet/outlet temperature 40º C/45º C; source side water inlet/outlet temperature 15º C/7º C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3, Circle water type nominal cooling workingcondition: user side water inlet/outlet temperature 12º C/7º C; source side water inlet/outlet temperature 30º C/35º C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Circle water type nominal heatinging workingcondition: user side water inlet/outlet temperature 40º C/45º C; source side water inlet/outlet temperature 20º C/15º C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
4, Standard cooling working condition: User side water inlet/outlet temperature 12º C/7º C; Source side water inlet/outlet temperature 15º C/20º C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Standard heating working condition: User side water inlet/outlet temperature 40º C/45º C; Source side water inlet/outlet temperature 15º C/10º C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5, The above parameters based on Refrigearnt R22, for parameters based on other refrigerants please contact us. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6, The product parameters may have some difference from the final product because of products updating, please refer to final product label when buy. Our company keeps the right to interpret. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Zhejiang Cen New Energy Technology Co., Ltd. Our company is still developing more styles of products. We take the technology as the core\regard the quality as life\treat the user as god. We dedicated to provide you with the highest cost-effective energy-saving products\high-quality engineering design and meticulous transformation of after-sales service!
Our main products as follows:
Air-source heat pump unit for household and commercial
Ground source heat pump unit
Water source heat pump unit
Combine cooling\heating and hot water heat pump unit
Swimming pool heat pump unit
Heat recovery of centre air-conditioner so on energy-saving products, our products passed prove ISO9001\CCC\CE certificate.
Product features: Reasonable structure\stable quality\reliable and nice.
We consistently insist on the sane business strategy. We don't demand the biggest, only best. Take the most serious attitude, do the most professional thing. Let us enhance friendship with large clients and sincere cooperation, create brilliance!