Price: | US $ 600/Piece |
---|---|
Trade Terms: | FOB,CFR,CIF |
Min Order: | 1/Piece |
Pay Type: | L/C,T/T,Western Union |
Prod Model: | A+E 81F |
---|---|
Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
Item: | Magnetic Flow Meter |
Velocity Range: | 0.2~8 M / S (0.66 to 26.26 Ft / S) |
Electrode: | 316L, Hc, Hb, Ti, Ta |
Output: | 4-20mA DC, Pulse, RS485 |
Pressure: | Max.16 MPa |
Media Temperature: | Max 150 C |
Ambient Temperature: | Sensor 80 C, Converter 50 C |
Power Supply: | 220VAC or 24VDC |
Grounding: | S.S, Hc, Ti, Ta, Cu |
Lining Material: | F4, PTFE, F46, Fs, Rubber |
Type: | Electromagnetic Flow Meter |
Measuring Principle: | Electrical Principles |
Measuring Media: | Liquid |
Accuracy: | ?à0.6-1% |
Main Application: | Corrosive Liquid/Gas |
Sensor: | Tube/Flange |
Application: | Enviromental, Industrial |
Size: | Dn 15-800 (1/2" to 31-1/2") |
Anti Corrosive Fluids Magnetic Flow Meter (A+E 81F)
Highlights
--aluminum alloy housing magnetic flow meter, good enclosure.
--unique 6 layer circuit board design, immune to electromagnetic interference.
--fault detective supported like excitation circuit turn-off.
--plug & play terminal block
--damp-proof sealed sensor treatment
--reliable blank pipe inspection
Features
--large choice of liner materials like F4, PTFE, F46, Fs and rubber.
--electric conductivity of medium can be used for detection of product change.
--no additional pressure loss magnetic flow meter.
--no moveable parts and long working life.
--site digital LCD displays instantaneous flow, accumulative flow, flow rate.
--various output method, like 4-20mA, 0-5V, RS485 and pulse.
--compact, split and plug-in types optional.
--change the grounding as the third electrode.
Item | magnetic flow meter |
Applicable pipe size | DN 15-800 (1/2'' to 31-1/2'') |
Applicable media | liquid with conductivity > 5 uS / cm |
Accuracy | 0.5%FS, 1.0%FS |
Process connection | flange, ANSI / GB / JIS, 1.0MPa, 1.6MPa, 4.0MPa, 16MPa optional |
Processing temperature | -20 to 150°C, according to lining material |
Ambient condition | -40 to 80°C, relative humidity <95% |
Power supply | AC220V, 50Hz / DC24V / battery |
Display | backlight LCD |
Operation | 4 light touch buttons |
Signal output | 4-20mA, loading resistance 750Ω, |
pulse, 0-3kHz, 5V, | |
RS485 | |
Consumption | <8W |
Cable inlet/outlet | M20*1.5 |
Protection | transducer IP68, converter IP65 |
Tube material | carbon steel, stainless steel optional |
Lining material | PTFE, rubber, polyurethane, F46, Fs optional |
Electrode material | stainless steel, Hastelloy B, Hastelloy C, Titanium, Tantalum, Platinum optional |
Grounding | made into a third electrode, same material with electrode |
Industries | chemical, environmental, metallurgical, pharmaceutical, papermaking, water supply and drainage, etc. |
Main performances of the lining materials | ||
Lining material | Main Performance | Applications |
Teflon | 1.The most steady material in plastics which is resistible to boiling hydrochloric acid, vitriol fortis as well as strong alkali and organic impregnates. | Strong corrosive mediums such as strong acid and alkali |
F46 | 1.Have the same abrasion resistance with PTFE. | 1.The same as PTFE. |
Neoprene | 1.Be of good elasticity, retractility and abrasion resistance. | Water, sewage and slurry, mineral serosity of low abrasion. |
Polyurethane | 1.Be of good abrasion resistibility. | Applicable in mineral serosity, slurry and coal slurry of high abrasion. |
Main performances of the electrode materials | |
Electrode material | Applications |
Stainless steel SS316 | Applicable in water, sewage and corrosive mediums. Widely used in industries of petrol, chemistry, carbamide, etc. |
Hastelloy B(HB) | Having strong resistance to hydrochloric acid of any consistence which is below boiling point. Also resistible against vitriol, phosphate, hydrofluoricacid,organic acid etc which are oxidable acid, alkali and non-oxidable salt. |
Hastelloy C(HC) | Be resistant to oxidable acid such as nitric acid, mixed acid as well as oxidable salt such as Fe+++,Cu++and sea water |
Titanium | Applicable in seawater, and kinds of chloride, hypochlorite salt, oxidable acid (including fuming nitric acid), organic acid, alkali etc. Not resistant to a pure reducing acid(such as sulphuric acid, hydrochloric acid)corrosion. But if acid contains antioxidant(such as Fe+++,Cu++) is greatly reduce corrosion. |
Tantalum | Having strong resistance to corrosive mediums that is similar with glass. Almost applicable in all chemical mediums. Except for hydrofluoric acid, oleum and alkali. |
Platinum-iridium | Almost be applicable in all chemical mediums except for aqua fortis, ammonium salt. |
Warranty
All AEAD manufactured magnetic flow meters are guaranteed in 12 month since delivery.
Company
AEAD Technology moves to Chinese first free trade zone --Shanghai Pilot Free Trade Zone in Nov. 2014. That is a milestone for the company development to global market.