Categories
Price: | Negotiable/Piece |
---|---|
Trade Terms: | FOB,CFR,CIF |
Min Order: | 1/Piece |
Pay Type: | L/C,T/T,Paypal,Money Gram,Western Union |
Model | RSP-2400-12 | RSP-2400-24 | RSP-2400-48 | |
Output | DC VOLTAGE | 12V | 24V | 48V |
RATED CURRENT | 166.7A | 100A | 50A | |
CURRENT RANGE | 0166.7A | 0-100A | 0-50A | |
RATED POWER | 2000.4W | 2400W | 2400W | |
RIPPLE & NOISE (max.) | 150mVp-p | 150mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 10.8 ~ 13.2V | 22 ~ 28V | 43 ~ 56V | |
VOLTAGE TOLERANCE | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE TIME | 1000ms, 80ms at full load | |||
HOLD UP TIME (Typ.) | 12ms at full load | |||
Input | VOLTAGE RANGE | 180 ~ 264VAC 254 ~ 370VDC | ||
FREQUENCY RANGE | 47 ~ 63Hz | |||
POWER FACTOR (Typ.) | 0.95/230VAC at full load | |||
EFFICIENCY (Typ.) | 88% | 90.5% | 91.5% | |
AC CURRENT (Typ.) | 15.5A/180VAC 12A/230VAC | |||
INRUSH CURRENT (Typ.) | 60A/230VAC | |||
LEAKAGE CURRENT | <2.0mA / 240VAC | |||
PROTECTION | OVERLOAD | 100 ~ 112% rated output power | ||
User adjustable continuous constant current limiting or constant current limiting with delay shutdown after 5 seconds, re-power on to recover | ||||
OVER VOLTAGE | 13.8 ~ 16.8V | 28.8 ~ 33.6V | 57.6 ~ 67.2V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||||
OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | |||
FUNCTION | AUXILIARY POWER(AUX) | [email protected](Only for Remote ON/OFF control) | ||
REMOTE ON/OFF CONTROL | Please see the Function Manua | |||
ALARM SIGNAL OUTPUT | Please see the Function Manua | |||
OUTPUT VOLTAGE TRIM | 2.4 ~ 13.2V | 4.8 ~ 28V | 9.6 ~ 56V | |
CURRENT SHARING | Please see the Function Manua | |||
ENVIRONMENT | WORKING TEMP. | -20 ~ +70 (Refer to "Derating Curve") | ||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||
STORAGE TEMP., HUMIDITY | -40 ~ +85 , 10 ~ 95% RH | |||
TEMP. COEFFICIENT | ±0.05%ºC (0 ~ 50ºC ) | |||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |||
SAFETY & FUNCTION EMC | SAFETY STANDARDS | UL60950-1, TUV EN60950-1 approved | ||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | |||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH | |||
EMC EMISSION | Compliance to EN55022 (CISPR22) Conduction Class B, Radiation Class A ; EN61000-3-2,-3 | |||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A | |||
OTHERS | MTBF | 104.5K hrs min. MIL-HDBK-217F (25ºC ) | ||
DIMENSION | 278*177.8*63.5mm (L*W*H) | |||
PACKING | 3.3Kg; 4pcs/14.2Kg/1.81CUFT | |||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The tinal equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies". 5. Can't use the PWM signal to control th output voltage. 6. PV(PIN3) AND ps(pin4) of CN1 ot CN2 must be shorted if "Output Voltage TRIM" function is not used. Otherwise, the power supply unit will have no output. PV(PIN3) and PS(PIN4) of CN1 or CN2 must be disconnected if "Output Voltage TRIM" function is used. Otherwise, the internal electrical components may be damaged, and the power supply unit may thus be out of order. |
Prod Model: | RSP-2400-24 |
---|---|
Markets: | North America,South America,Eastern Europe,Southeast Asia,Africa,Oceania,Mid East,Eastern Asia,Western Europe |
Rated Power: | 2400W |
Rated Current: | 100A |
Ripple & Noise: | 150MVP-P |
Voltage Adjustment Range: | 22 ~28V |
Certificates: | UL,CB,CE,EMC,TUV |
Standard Packing: | 3.3kg; 4PCS/14.2kg/1.81cuft |
Dimesion: | 278*177.8*63.5mm (L*W*H) |
Output Type: | Single |
Connection Mode: | Parallel Switching Power Supply |
Starting Mode: | Self-excited Switching Power Supply |
Voltage Regulating Mode: | Frequency Modulation Type |
Power Supplying System: | Level 2 Power Distribution Equipment |
Certification: | TUV, EMC |
Warranty: | 5 Years |
Output Power: | 2400W |
Input Voltage: | 180 ~ 264VAC 254 ~ 370VDC |